• 제목/요약/키워드: Lamp

검색결과 2,685건 처리시간 0.028초

형광램프대체용 LED FDL 개발 (Development of The LED FDL for Replacing Fluorescent Lamp)

  • 양병문;장우진;차재상
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

Halogen lamp 광조사기와 Plasma xenon arc lamp 광조사기에 의한 광중합 복합레진의 중합률 비교 (COMPARISON OF THE DECREE OF CONVERSION IN LIGHT-CURED COMPOSITE RESIN CURED BY HALOGEN AND PLASMA XENON ARC LAMP CURING UNIT)

  • 이영준;정병초;최남기;양규호
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.328-336
    • /
    • 2002
  • 본 연구의 목적은 일반 halogen lamp 광조사기와 비교하여 plasma xenon arc lamp 광조사기의 광중합 능력을 평가하기 위한 것이다. 7mm의 내경과 1mm, 2mm, 3mm 두께를 갖는 레진 시편을 aluminum 주형상에서 제작하여 plasma xenon arc lamp 광조사기는 2초, 3초, 6초, halogen lamp 광조사기는 20초, 40초, 60초 동안 광조사한 후 Raman spectroscopy를 이용하여 레진 시편 표면과 후면의 중합률을 측정하였다. 표면 중합률은 광조사 시간이 증가함에 따라 halogen lamp 광조사기와 plasma xenon arc lamp 광조사기 모두에서 유의성있게 증가하였으며 전반적인 중합률은 halogen lamp 광조사기에서 더 높았으나 plasma xenon arc lamp 광조사기와 유의한 차이는 없었다. 광조사 시간이 증가함에 따라 halogen lamp 광조사기의 경우 후면 중합률은 모든 두께에서 점차 증가하였으나 1.2mm 두께에서는 유의한 차이가 없었으며 plasma xenon arc lamp 광조사기로 중합한 경우에는 모든 두께에서 조사시간이 증가할수록 중합률은 유의성있게 증가하였다. 이상의 결과로 plasma xenon arc lamp 광조사기의 강한 광도가 광조사 시간의 감소를 완전히 보상하지는 못하는 것으로 판단되므로 plasma xenon arc lamp 광조사기로 광중합 복합레진을 중합할 경우 2mm이내의 적층 충전이 요구되며 또한 제조회사가 제시한 조사 시간보다 추가적인 광조사가 필요할 것으로 판단된다.

  • PDF

조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화 (Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting)

  • 손민우;이덕희;서정철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

가로등설비 누전시 건조상태와 침수상태에 대한 전위분포 분석 (The Analysis on the Electric Potential Distribution of Dry and Submerged Condition by Electric Leakage in Street Lamp)

  • 홍성호;박상태;김상철
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.44-50
    • /
    • 2008
  • This paper presents study on the electric potential distribution when have a short in street lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

육상용 LED 램프의 선박 적응력에 관한 연구 (A study on the accommodation of common LED to shipboard)

  • 정지현;박환철;김용주;한승재;서상도;김민석
    • 수산해양기술연구
    • /
    • 제46권4호
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

발광·무광 적외선등 조사가 실험적 통증역치에 미치는 효과 비교 (Comparison of the Effects of Luminous Lamp, and Nonluminous Lamp Radiation on Experimental Pain Threshold Sensitivity)

  • 임인혁;이정원;조수원
    • 한국전문물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study was to compare the experimental pain threshold when used in luminous lamp radiation and nonluminous lamp radiation with healthy person. Thirty normal subjects were randomly assigned two groups: a luminous lamp radiation group, and a nonluminous lamp radiation group. The infrared lamps were applied on L3 for thirty minutes. Each group was measured for experimental pain threshold and local temperature before, 15 and 30 minute radiation. For statistical differences in change of the experimental pain threshold and local temperature due to differences in lamp ray was compared using the independent t-test. And, General linear model for profile plots test was used. The results were as: 1. Local temperature was significantly increased in the nonluminous lamp group (p<.01). 2. Experimental pain thershold was significantly increased in the luminous lamp group (p<.05),(p<.01). This study indicate that luminous lamp radiation was more effects of increase experimental pain thershold than nonluminous lamp radiation. Further study is needed to compare the effects of after period radiation.

  • PDF

무전극램프의 출력전력 변화에 따른 새로운 모델링 기법 (New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp)

  • 임병노;장목순;신동석;박종연
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

가로등설비 누전시 전위분포에 대한 실험연구 (The Experimental Study on the Electric Potential Distribution by Electric Leakage in Street Lamp)

  • 박상태;이복영;홍성호;최충석;길형준;한운기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.222-227
    • /
    • 2005
  • This paper presents study on the electric potential distribution when have a short in skeet lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible to more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

  • PDF

솔라시뮬레이터의 램프뱅크 설계에 관한 연구 (A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR)

  • 백상화
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.

전조용 백열등의 조도 특성 (Illuminating Characteristics of an Incandescent Lamp)

  • 김태한;이경진;이정택
    • Journal of Biosystems Engineering
    • /
    • 제25권1호
    • /
    • pp.25-32
    • /
    • 2000
  • Motivated by the need for developing the more efficient lighting system for light culture in the greenhouses, this paper aims to predict the illumination of incandescent lamp according to various levels of lighting and various kinds of the lamp. The results obtained in this experiment are summarized as follows. 1. The general equation to predict the illumination according to the kind of incandescent lamp and the installation height was suggested as {{{{y= { a + bx+ cx^2} over { 1+dx+ex^2~ + fx^3} [lx]}}}} , where , a, b, c , d, e and of were arbitrary constants. 2. Maximum illumination of hat-covered lamp of 60 W was 1.2 -1.5 times as many as uncovered lamp. 3. Maximum illumination of yellow color painted lamp of 100 W was 1.3 times as many as unpainted lamp.

  • PDF