• Title/Summary/Keyword: Laboratory test bench

Search Result 36, Processing Time 0.022 seconds

A Feedback Control of Pump-Controlled Electro-Hydrostatic Actuation System (펌프 가변제어기반 유압시스템의 피드백 제어)

  • Ryu, Jae-Kwan;Seo, Hyung-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.837-843
    • /
    • 2016
  • This paper presents a position control strategy for a pump-controlled electro-hydrostatic actuator (EHA) using feedforward control with disturbance compensation. As the disturbance observer is used to estimate nonlinear dynamics of EHA, which has valve-opening conditionals, as well as external disturbances, an additional feedforward control is adopted to achieve rapid response. The effectiveness of the proposed control strategy is verified through experiment using an EHA test bench. The proposed controller shows better tracking performance compared with a conventional PID controller.

A study of friction properties of the automotive engine oils (자동차 엔진오일의 마찰특성에 관한 연구)

  • 강석춘;김종호;조원호;정근우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.85-93
    • /
    • 1991
  • Engine oil of the vehicle is very important to reduce friction and wear of the moving parts as long as possible without deterioration. As the technique of engine design and manufacturing improves, the performance of engine was increased greatly with the improvement of the quality of engine oil. All the additives and formulations skill of engine oil produced in our country are imported from foreign country. So it is necessary to study the basic knowledge of the mechanism of friction and wear of engine oil for the development of our own formula and additives. From this research, the basic mechanism of tribology and the change of oil properties were studied with a home made oil and two foreign oils by bench and engine test and laboratory works.

  • PDF

Analysis of Blood Cell Images Using Smartphone-based Mobile SmartScope (스마트폰 기반 Mobile SmartScope를 이용한 혈구 영상 분석)

  • Park, Choonho;Cho, Myoung-Ock;Lee, Donghee;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.2
    • /
    • pp.25-31
    • /
    • 2012
  • High-performance smartphones, equipped with a digital camera and an application software, can render conventional bench-top laboratory instruments mobile at affordable costs. As the smartphone-based devices are portable and wireless, they have wide applications especially in providing point-of-care (POC) tests in resource-constrained areas. We developed a hand-held diagnostic system, Mobile SmartScope, which consists of a small optical unit integrated with a smartphone. The performance of the SmartScope was favorably compared with that of conventional light microscopy in detecting and quantifying red blood cells. We also evaluated the fluorescence detection limit of the SmartScope incorporated with a blue light-emitting diode and appropriate optical filters by using fluorescently labeled microbeads for intensity calibration.

Example of Air Exposure Assessment for Fire Extinguishing Agent Residues (소화약제 잔류물질에 대한 공기 중 노출평가 사례)

  • Daesung Lim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.14-17
    • /
    • 2024
  • Objectives: This is a case of air exposure assessment conducted after researchers complained of headaches and odor due to residual substances from fire extinguishing agents spread throughout the laboratory due to a malfunction of the fire extinguishing facility. Methods: A component analysis was conducted on the residual substances of a fire extinguishing agent spread in a laboratory using Py-GC-MS (pyrolysis gas chromatography mass spectrometry) at the research institute's own central equipment research center. As a result of the component analysis, several types of substances were detected. Among these, five types of substances subject to work environment measurement in the aromatic hydrocarbon series, which can affect headaches and odor, were selected as substances subject to exposure assessment in the air, and the measurement and analysis methods of the target substances were conducted in accordance with the KOSHA Guide for each substance. Conclusions: The measurement results showed that all 5 types of substances were not detected at locations A, B, and C. This is believed to be the result of the residual substances in the fire extinguishing agent being measured when approximately two months had elapsed after being exposed to the test bench, and the substances already exposed had volatilized and disappeared. In this survey, it is believed that the measurement process is more important than the measurement results.

Development of a Rapid Automated Fluorescent Lateral Flow Immunoassay to Detect Hepatitis B Surface Antigen (HBsAg), Antibody to HBsAg, and Antibody to Hepatitis C

  • Ryu, Ji Hyeong;Kwon, Minsuk;Moon, Joung-Dae;Hwang, Min-Woong;Lee, Jeong-Min;Park, Ki-Hyun;Yun, So Jeong;Bae, Hyun Jin;Choi, Aeran;Lee, Hyeyoung;Jung, Bongsu;Jeong, Juhee;Han, Kyungja;Kim, Yonggoo;Oh, Eun-Jee
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.578-584
    • /
    • 2018
  • Background: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). Methods: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs-Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)-using 20 seroconversion panels and 3,500 clinical serum samples. Results: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. Conclusions: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.

Preliminary Experiments for the Remediation of Trichloroethene-Contaminated Groundwater Using Direct-Current and Zero-Valent Iron (0가 철과 직류전원을 이용한 TCE 오염 지하수의 정화기법 예비조사)

  • Moon, Ji-Won;Moon, Hi-Soo;Roh, Yul;Lee, Suk-Young;Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.34 no.3
    • /
    • pp.307-313
    • /
    • 2001
  • Reactive medium including zero-valent metals such as zero-valent iron ($Fe^0$) degrades chlorinated solvents as a contaminant plume flows through the treatment medium. Although the Feo based reactive barrier has been demonstnlted to be a cost effective for trichloroethenc (TCE)-contaminaled plume remediation, current approach is limited by low process eftlciency and uncertain, effective life of the medium. The objective of this study is to develop an enhanced treatment method of TeE-contaminated groundwater using Feo and direct current. The bench-scale test using flow-through $Fe^0$ reactor column confirmed that the application of direct current with $Fe^0$ is highly effective in enhancing the rate of TeE dechlorination. The dechlorination mechanism appears to be reductive, with the electrons supplied by the iron oxidation and external power supply serving as the additional source of electrons.

  • PDF

Electrokinetic Remediation of Organic Mixture Contaminated Soil (복합 유기 오염물로 오염된 세립질 지반의 Electrokinetic 정화 처리에 관한 연구)

  • 김수삼;한상재;김강호
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.349-356
    • /
    • 2002
  • In this research, phenol was selected as a representative hydrophilic organic compound and phenanthrene as a representative hydrophobic organic contaminant in petroleum. Fine-grained soil which was manufactured artificially in laboratory was contaminated and EK remediation tests were executed. Also, in order to increase removal efficiency, the surfactant that had been used with improvement technique at the pump-and-treat was used by enhanced method. In the test, the phenol which has high solubility is easily removed, but phenanthrene which has low solubility is almost not. Also, it seems to be the delay phenomenon that the phenanthrene is accumulated near the cathode department vicinity at the enhanced technique which applied the surfactant, but the removal efficiency increases as the surfactant concentration increases. By the test which increases with time, the enhanced method with increasing time is more efficient than the method with increasing surfactant.

A New Approach for Detection of Gear Defects using a Discrete Wavelet Transform and Fast Empirical Mode Decomposition

  • TAYACHI, Hana;GABZILI, Hanen;LACHIRI, Zied
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • During the past decades, detection of gear defects remains as a major problem, especially when the gears are subject to non-stationary phenomena. The idea of this paper is to mixture a multilevel wavelet transform with a fast EMD decomposition in order to early detect gear defects. The sensitivity of a kurtosis is used as an indicator of gears defect burn. When the gear is damaged, the appearance of a crack on the gear tooth disrupts the signal. This is due to the presence of periodic pulses. Nevertheless, the existence of background noise induced by the random excitation can have an impact on the values of these temporal indicators. The denoising of these signals by multilevel wavelet transform improves the sensitivity of these indicators and increases the reliability of the investigation. Finally, a defect diagnosis result can be obtained after the fast transformation of the EMD. The proposed approach consists in applying a multi-resolution wavelet analysis with variable decomposition levels related to the severity of gear faults, then a fast EMD is used to early detect faults. The proposed mixed methods are evaluated on vibratory signals from the test bench, CETIM. The obtained results have shown the occurrence of a teeth defect on gear on the 5th and 8th day. This result agrees with the report of the appraisal made on this gear system.

A Numerical Study for Design Optimization of Nozzle Injection Angle in Tenter Machine (텐터기 노즐 분사각의 최적설계를 위한 수치해석적 연구)

  • Chun, Du Hwan;Park, Si Woo;Kim, Jung Han
    • Textile Coloration and Finishing
    • /
    • v.25 no.2
    • /
    • pp.134-139
    • /
    • 2013
  • A tenter is very important to dry and heat-set fabrics in textile dyeing and finishing industry. However, the tenter machine typically utilizes more than 80% of all the power in dyeing system, and yet is one of the primary machine which affects quality of fabrics. Therefore, performance optimization of the tenter machine is required to reduce energy consumption and enhance quality of fabrics. To optimize the tenter machine, it is important to maintain the uniform flow rate, which can be obtained by optimizing a nozzle geometry. In this study, emboss hole angle was investigated as main parameter in flow rate uniformity and heat flux efficiency. The analysis results were compared with those acquired from bench-scale dryer test in the laboratory. The tenter machine performance simulated by Computational Fluid Dynamics(CFD) was optimized by controlling emboss hole angle.

CHEMICAL EFFECTS ON PWR SUMP STRAINER BLOCKAGE AFTER A LOSS-OF-COOLANT ACCIDENT: REVIEW ON U.S. RESEARCH EFFORTS

  • Bahn, Chi Bum
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.295-310
    • /
    • 2013
  • Industry- or regulatory-sponsored research activities on the resolution of Generic Safety Issue (GSI)-191 were reviewed, especially on the chemical effects. Potential chemical effects on the head loss across the debris-loaded sump strainer under a post-accident condition were experimentally evidenced by small-scale bench tests, integrated chemical effects test (ICET), and vertical loop head loss tests. Three main chemical precipitates were identified by WCAP-16530-NP: calcium phosphate, aluminum oxyhydroxide, and sodium aluminum silicate. The former two precipitates were also identified as major chemical precipitates by the ICETs. The assumption that all released calcium would form precipitates is reasonable. CalSil insulation needs to be minimized especially in a plant using trisodium phosphate buffer. The assumption that all released aluminum would form precipitates appears highly conservative because ICETs and other studies suggest substantial solubility of aluminum at high temperature and inhibition of aluminum corrosion by silicate or phosphate. The industry-proposed chemical surrogates are quite effective in increasing the head loss across the debris-loaded bed and more effective than the prototypical aluminum hydroxide precipitates generated by in-situ aluminum corrosion. There appears to be some unresolved potential issues related to GSI-191 chemical effects as identified in NUREG/CR-6988. The United States Nuclear Regulatory Commission, however, concluded that the implications of these issues are either not generically significant or are appropriately addressed, although several issues associated with downstream in-vessel effects remain.