• Title/Summary/Keyword: Laboratory test

Search Result 6,923, Processing Time 0.032 seconds

Obtaining Reference Intervals of HbA1c by Immunoturbidimetry (면역비탁법에 의한 HbA1c의 참고범위 설정)

  • Kim, Jae-Sub;Park, Ki-Hyun;Yu, Sun-Woo;Lee, Bum-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • HbA1c is the major fraction of glycated hemoglobin, and used primarily to identify the average plasma glucose concentration over prolonged periods of time, mostly 2-3 months. It is used as markers for the diagnosis and monitoring of diabetic patients and increasingly used a marker in health screening check up for general populations. In this study, HbA1c was measured with Cobas integra 800 (Roche Diagnostics, Mannheim, Germany), using immunoturbidimetry principles. We established the reference interval for HbA1c with Cobas integra 800 and evaluated its significance. The study subjects were 36,140 (male 57.5%, and female 42.2%) who visited the Health Promotion Center of a tertiary care center in Seoul for health checkup from January to September, 2008. HbA1c levels were measured with immunoturbidimetric method. Statistical evaluation was done with SPSS. Comparison between male and female was checked with Mann-Whitney test, and among age groups with Kruskal-Wallis test. Reference interval for HbA1c was from 4.8% to 6.1%. There was no significant difference between male and female with Mann-Whitney test (P=0.539). There was significant difference among age groups with Kruskal-Wallis test (P<0.05). Reference interval for HbA1c with Cobas integra 800 was 4.8~6.1%, which was different from conventional one, 4.4-6.4%. Establishment of reference interval for each principle is needed.

  • PDF

Investigation of Red Cell Antiobody Screening Tests Gyeonggi Areas (경기일부지역의 적혈구 항체선별검사의 실태조사)

  • Kim, Dai-Joong;Sung, Hyun-Ho;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.1
    • /
    • pp.36-40
    • /
    • 2016
  • Red blood cell (RBC) alloimmunization results from genetic disparity of RBC antigens between donor and recipients. The discrepancy of RBC antibody screening test occurs when the results of red cell tests do not agree with those of the serum test. In order to select the proper blood units for transfusion, clarification of the cause of discrepancies is essential. The RBC antibody screening test is an easy, quick, and reliable method for detection of clinically significant antibodies. Antibody screening and identification is recommended prior to transfusion to determine whether there is blood group incompatibility. We reported that phenotyping for E, D, M, E+c, and C+e antibody screening test should be extended. Therefore, these results indicate that anti-D and anti-E alloantibodies were major risk factors for haemolytic disease of the newborn or delayed haemolytic transfusion reactions in this study population. We suggested that its antibody screening be adapted to blood safety interventions. Targeted screening of selected recipients at risk offers less value than universal antibody screening, and more research is needed to determine the real incidence of this national condition.

IgG Western Blot for Confirmatory Diagnosis of Equivocal Cases of Toxoplasmosis by EIA-IgG and Fluorescent Antibody Test

  • Khammari, Imen;Saghrouni, Fatma;Yaacoub, Alia;Meksi, Sondoss Gaied;Ach, Hinda;Garma, Lamia;Fathallah, Akila;Said, Moncef Ben
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.4
    • /
    • pp.485-488
    • /
    • 2013
  • The performance values of available techniques used in serodiagnosis of toxoplasmosis are satisfactory but they raise problems of equivocal and discordant results for very low IgG titers. Recently marketed, LDBio-Toxo II IgG Western blot (IB) showed an excellent correlation with the dye test. We estimated the proportion of equivocal and discordant results between the enzyme immunoassay Platelia Toxo IgG (EIA-IgG) and fluorescent antibody test (FAT) and assessed the usefulness of the IB as a confirmatory test. Out of 2,136 sera collected from pregnant women, 1,644 (77.0%) tested unequivocally positive and 407 (19.0%) were negative in both EIA-IgG and FAT. The remaining 85 (4%) sera showed equivocal or discordant results. Among them, 73 (85.9%) were positive and 12 (14.1%) were negative in IB. Forty-one (89.1%) equivocal sera in EIA-IgG and 46 (86.8%) equivocal sera in FAT were positive in IB. Reducing the cut-off values of both screening techniques improved significantly their sensitivity in detecting very low IgG titers at the expense of their specificity. In conclusion, equivocal results in routine-used techniques and their discordance in determination of the immune status in pregnancy women were not uncommon. IB test appeard to be highly useful in these situations as a confirmatory technique.

Analysis of Ethernet Wwitch Measurement Uncertainty for KOLAS Testing Laboratory Accreditation (KOLAS 공인시험기관 인정을 위한 이더넷 스위치의 측정불확도 분석)

  • Lee, Jae-Jeong;Ryu, Han-Yand;Nam, Ki-Dong;Kim, Chang-Bong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.12
    • /
    • pp.1-8
    • /
    • 2011
  • Actively in progress in the field of general industrial KOLAS (Korea Laboratory Accreditation Scheme) accreditation test the switch, router, network equipment, such as accreditation status in the field can not be found. Company's self-tsting or BMT (Bench Marking Test) through the evaluation process for network equipment, but the test reports issued by accredited laboratories with quality differences. Requested by public institutions or other providers of accredited test reports increasing demand for network equipment in Korea accredited testing laboratory shall be made as soon as possible. In this paper, as required by KOLAS in the field of network equipment testing laboratory accreditation program in the process acquired through the analysis of measurement uncertainty and, to propose effective direction.

Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia (빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교)

  • Kim, Il Taek;Kim, Jong Seok;Park, Yeon Bo;Lim, Jae Sil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

Evaluation of Life Time for Anti-Corrosive Methods for Marine Steel Sheet by Cyclic Corrosion Test (실내 가속부식시험을 통한 해양 강관합성 말뚝의 방식 기법 수명 평가)

  • Park, J.W.;Lee, J.G.;Lee, K.W.;Kim, J.H.;Jung, M.K.;Lee, J.H.
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.243-250
    • /
    • 2009
  • When a steel sheet pipe applied to marine environment, an anti-corrosive coating should be treated to obtain long-term life-time for steels, especially, splash zone. Although anti-corrosive property of coatings is required to be tested in real marine environment, it is difficult because of long test time such as 20 years or more time. Therefore, we used cyclic corrosion tester in a laboratory, which has similar conditions with salt-dry-wet process such as real marine environment. Anti-corrosive properties of the coatings and two steels were tested their anti-corrosive properties under cyclic corrosion test conditions(KS D ISO 14993) and the results were compared with estimate life-time in real marine environment. According to cyclic corrosion test, accelerated corrosive factor of each anti-corrosive coating was investigated accelerated corrosive factor from impedance with EIS method. Accelerated corrosive factor of type SS400 carbon steel and A690 was also investigated their accelerated corrosive factor from the regression curves of weigh loss results. One of the anti-corrosive coatings showed about 50 years life-time compared with standard sample life-time. Carbon steel SS400 showed from 0.1 mm/yr to 0.06 mm/yr as its corrosion rate.

Monitoring of Aluminium Phosphide Residues in Wheat and Wheat Flour (밀과 밀가루 중 알루미늄포스파이드 잔류량 모니터링)

  • Choi, Yong-Hoon;Yoon, Sang-Hyeon;Hong, Hye-Mi;Kang, Yun-Sook;Chae, Kab-Ryong;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.532-536
    • /
    • 2005
  • GC-NPD analysis was performed on residues of aluminium phosphide in raw wheat and wheat products by trapping gaseous phosphine in the headspace of vessel. In Australian wheat, over 95% of samples were detected below 1 ppb, considered as safe level, whereas in American wheat, about 70% of 58 samples were detected within 1-10 ppb with 4 showing over 10 ppb. About 14-22% phosphine residues of raw wheat were retained after milling process. Wheat samples of same origin showed significant varying levels of phosphine.

Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF) (근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가)

  • Park, Kyoung-Ho;Ahn, Yong-Ho;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

Damage detection of shear buildings using frequency-change-ratio and model updating algorithm

  • Liang, Yabin;Feng, Qian;Li, Heng;Jiang, Jian
    • Smart Structures and Systems
    • /
    • v.23 no.2
    • /
    • pp.107-122
    • /
    • 2019
  • As one of the most important parameters in structural health monitoring, structural frequency has many advantages, such as convenient to be measured, high precision, and insensitive to noise. In addition, frequency-change-ratio based method had been validated to have the ability to identify the damage occurrence and location. However, building a precise enough finite elemental model (FEM) for the test structure is still a huge challenge for this frequency-change-ratio based damage detection technique. In order to overcome this disadvantage and extend the application for frequencies in structural health monitoring area, a novel method was developed in this paper by combining the cross-model cross-mode (CMCM) model updating algorithm with the frequency-change-ratio based method. At first, assuming the physical parameters, including the element mass and stiffness, of the test structure had been known with a certain value, then an initial to-be-updated model with these assumed parameters was constructed according to the typical mass and stiffness distribution characteristic of shear buildings. After that, this to-be-updated model was updated using CMCM algorithm by combining with the measured frequencies of the actual structure when no damage was introduced. Thus, this updated model was regarded as a representation of the FEM model of actual structure, because their modal information were almost the same. Finally, based on this updated model, the frequency-change-ratio based method can be further proceed to realize the damage detection and localization. In order to verify the effectiveness of the developed method, a four-level shear building was numerically simulated and two actual shear structures, including a three-level shear model and an eight-story frame, were experimentally test in laboratory, and all the test results demonstrate that the developed method can identify the structural damage occurrence and location effectively, even only very limited modal frequencies of the test structure were provided.

Subacute Oral Toxicity and Bacterial Mutagenicity Study of a Mixture of Korean Red Ginseng (Panax ginseng C.A. Meyer) and Salvia plebeia R. Br. Extracts

  • Seo, Hwi Won;Suh, Jae Hyun;Kyung, Jong-Soo;Jang, Kyoung Hwa;So, Seung-Ho
    • Toxicological Research
    • /
    • v.35 no.3
    • /
    • pp.215-224
    • /
    • 2019
  • As various populations are rapidly becoming an aging society worldwide and interest in health issues has increased, demand for functional foods including herbal products has increased markedly to maintain a healthy state which has led to safety issues about their intake as an inevitable result. The objective of this study was to identify the safety profile of a Korean red ginseng and Salvia plebeia R. Br. extract mixture (KGC-03-PS) which is a valuable ingredient that can be used as a functional food. In the present study, the subacute oral toxicity and bacterial reverse mutagenicity of KGC-03-PS were evaluated. Sprague Dawley rats were administered KGC-03-PS orally for 28 days by gavage. Daily KGC-03-PS dose concentrations were 0, 500, 1,000, or 2,000 mg/kg body weight (bw) per day. Bacterial reverse mutation test with KGC-03-PS dose levels ranging from 312.5 to $5,000{\mu}g/plate$ was carried out by OECD test guideline No. 471. Five bacterial strains (Salmonella typhimurium TA98, TA100, TA1535, TA1537, and Escherichia coli WP2) were tested in the presence or absence of metabolic activation by plate incorporation method. There were no toxicological effects related with test substance in the clinical evaluation of subacute oral toxicity test including clinical signs, body weight, and food consumption. Moreover, no toxicological changes related to KGC-03-PS were observed in the hematological and serum biochemical characteristics as well as in the pathological examinations, which included organ weight measurements and in the gross- or histopathological findings. KGC-03-PS did not induce an increase in the number of revertant colonies in all bacterial strains of the bacterial reverse mutation test. The no-observed-adverse-effect level of KGC-03-PS is greater than 2,000 mg/kg bw/day, and KGC-03-PS did not induce genotoxicity related to bacterial reverse mutations under the conditions used in this study.