• Title/Summary/Keyword: Laboratories of University

Search Result 1,467, Processing Time 0.03 seconds

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

Analysis of a Principal's Cognition on his Job Performance in Meister High Schools (마이스터고등학교 교장의 직무수행에 대한 교장의 인식분석)

  • Hyun, Su;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.27-47
    • /
    • 2013
  • This study aims to suggest a way to improve the professional abilities of the principals of meister high schools by analysing their perception of the standards of performance of their duties. To carry out this study, we have developed the standards of performance of the duties of the principals of meister high schools through the systematic research on the realm of the duties of the principals of meister high schools, and analysed the principals' perception of their duties using the developed standards of performance of their duties. The results of this study are as followed. First, In the stage of planning the school management, the school management plan, the ways to get budget, the plan for evaluation and feedback of the accomplishment of the performance of school management plan should be included. Second, The area of the school management is subdivided into securing school budget, reviewing and arranging the budgets demanded by teachers, executing school budgets, obtaining school equipments and facilities, maintaining school equipments and facilities, managing school feeding, organizing and operating school steering committee, reflecting the opinions of school steering committee. Third, The school curriculum should be developed by a job analysis and the teaching should reflect the analysis. Fourth, The area of the career path and the management of the career for young meisters includes the analysis of the demand of students, parents, and companies, the development of meister growth route and program for managing their career, and the analysis of meister growth route and reflection of the results of the analysis. Fifth, The field of guiding students includes supporting the students counseling service, and managing a variety of school events. 6th, In the realm of cooperation with communities are included designing programs for collaborating and training students with companies, building cooperation with companies, and obtaining supports from communities and related organizations. 7th, In the area of supporting teachers to improve their professional competence, it figured out that supporting teachers' voluntary learning and studying should take a top priority. In conclusion, it is necessary for meister high school principals to have capability to deal with meister growth route and career management, supporting collaboration with other organizations, building and managing laboratories, encouraging teachers' professional improvement, and operating school curriculum and teaching activities.

College-bound Curriculum Developement for Training of Atomic Industry Technician (원자력산업 중견전문인력 양성을 위한 전문대학 교육과정 개발)

  • Lyu, Kwang-Yeul;Kim, Sung-Soo;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.33-44
    • /
    • 2005
  • The objective of this study is to supply the good quality of experts the radiation industries in Korea and develop the major subject matter needed in the radiation industries and the curriculum in order to execute it for the variation of fields of employment at the department of radiation in the junior college and the development of the percentage of employment. In addition, this study is to improve the level of radiation experts engaged in the industries in quality, and it is to improve the social recognition of radiation rather negative now because of the development of radiation industry. As for the core results of this research, it was to suggest the detailed choice method curriculum proper to the service fields of radiation industries, but it may be subject to change due to each college's property and the educational objectives. From the result of this research above, it may be summed up as follows. First, as for the detailed curriculum by the service field, this study was to organize two subject matters: 1. the subject matter proper to the field of using the radiation, and 2. the subject matters proper to the safety control field of radiation. Second, as for the detailed curriculum by the pattern of industries, this study was to organize the four subject matters: 1. the subject matter needed in the manufactures, 2. the subject matter needed in the nondestructive testing industries, 3. the subject matter needed in the sales agencies, and 4. the subject matter needed in the laboratories. This study was to suggest the operational model about the curriculum in order to execute these subject matters. It could be executed as two methods below. First, one method is to execute the major systems by the medical field and industrial field in the third course at the department of radiation in the junior college now. Second, the other method is to make them specialize the industrial radiation in the Advanced Course(one year course) after the graduation of junior college. To operate these curricula successively it needs to assume the deeper research and the development of materials about the subject matters related to the nuclear radiation industries hereafter. In addition, it needs to solve the security of finance like the manpower of professor, space for practice, and the educational appliances, etc. needed in the operation of subject matters. Finally, the effect and result from the development or revision of college curriculum did not come out in a short time. It will require considerable time until the undergraduates at the department in the junior college finish a set of curriculum newly developed, and graduate the university, and can get the results while they engage in their works in the industrial sites. Accordingly, all the interested parties have to anticipate the results of this research with the patience in long-standing point of view. Also, this researcher considers it as it is willing to give them the continuous interest and support.

  • PDF

Relationship among Job Characteristics, Jod Satisfaction and Organizational Commitment of Dental Technicians (치과기공소 근무자의 직무관련 요인과 직무만족 및 조직몰입과의 상관관계)

  • Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.89-111
    • /
    • 1988
  • This study relates to the procedures and the attitude of dental technicians. In order to identify the attitude factors which have influence on the job satisfaction and the organizational commitment, self-administered questionnares were distributed by mail to 504 technicians randomlyselected from 482 dental laboratories registered in Korean Dental Lab. Association from February 6 to February 27, 1987. The following results were obtained: 1. Canonical correlation between the group of general variables and the group of job satisfactional variables was significant statistically as Rc=0.48. But canonical correlation between the group of general variables and the group of organizational commitment variables was insignificant statistically as Rc=0.37. 2. Canonical correlation between the group of job characteristic variables and the group of job satisfactional variables was highly significant statistically as Rc=0.69. Wage propriety, promotion opportunity and benefits propriety were highly influential factors among the job characteristic variables. 3. Canonical correlation between the group of job characteristic variables and the group of organizational commitment variables was highly significant statistically as Rc=0.61. Wage propriety, promotion opportunity of acquiring technique and duty importance were highly influential factors among the job characteristic variables. 4. The job characteristic variables which had influence on the job satisfaction varied statistically according to the general variables. in case of age, technical career, academic career and duty, the job characteristic variable was wage propriety and the business relations. 5. The job characteristic variables which had influence on the organizational commitment varied statistically according to the general variables. The case of male was applicable to wage propriety, the case of female was applicable to benefits propriety, the case of dental technicians who were less than 30 years old was applicable to wage propriety, the case of dental technicians who had more than 5 years technical career was applicable to monotonousness. 6. The most influential factor was wage propriety among job characteristic variables which influenced on the job satisfaction and the organizational commitment of dental technicians.

  • PDF

SysML-Based System Modeling for Design of BIPV Electric Power Generation (건물일체형 태양광 시스템의 전력발전부 설계를 위한 SysML기반 시스템 모델링)

  • Lee, Seung-Joon;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.578-589
    • /
    • 2018
  • Building Integrated Photovoltaic (BIPV) system is a typical integrated system that simultaneously performs both building function and solar power generation function. To maximize its potential advantage, however, the solar photovoltaic power generation function must be integrated from the early conceptual design stage, and maximum power generation must be designed. To cope with such requirements, preliminary research on BIPV design process based on architectural design model and computer simulation results for improving solar power generation performance have been published. However, the requirements of the BIPV system have not been clearly identified and systematically reflected in the subsequent design. Moreover, no model has verified the power generation design. To solve these problems, we systematically model the requirements of BIPV system and study power generation design based on the system requirements model. Through the study, we consistently use the standard system modeling language, SysML. Specifically, stakeholder requirements were first identified from stakeholders and related BIPV standards. Then, based on the domain model, the design requirements of the BIPV system were derived at the system level, and the functional and physical architectures of the target system were created based on the system requirements. Finally, the power generation performance of the BIPV system was evaluated through a simulated SysML model (Parametric diagram). If the SysML system model developed herein can be reinforced by reflecting the conditions resulting from building design, it will open an opportunity to study and optimize the power generation in the BIPV system in an integrated fashion.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Diagnostic Usefulness of Serum Level of Cyfra 21-1, SCC Antigen and CEA in Lung Cancer (폐암에서 혈중 Cyfra 21-1, SCC 항원 및 CEA의 진단적 유용성)

  • Kim, Kyoung-Ah;Lee, Me-Hwa;Koh, Youn-Suck;Kim, Seon-Hee;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Moon, Dae-Hyuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.846-854
    • /
    • 1995
  • Background: Cytokeratin 19 is a subunit of cytokeratin intermediate filament expressed in simple epithelia such as respiratory epithelial cells and their malignant counterparts. An immunoradiometric assay is available to detect a fragment of the cytokeratin, referred to as Cyfra 21-1 in the serum. This study was conducted to evaluate the clinical utility of this new marker in the diagnosis of lung cancer compared with established markers of squamous cell carcinoma antigen (SCC Ag) and carcino-embryonic antigen(CEA). In addition, we compared the diagnostic sensitivity and specificity of Cyfra 21-1 with those of SCC Ag in squamous cell carcinoma of the lung. We also measured the level of Cyfra 21-1 in the different stages of squamous cell carcinoma of the lung. Method: We measured Cyfra 21-1(ELSA-CYFRA 21-1), SCC Ag(ABBOTT SCC RIABEAD) and CEA(ELSA2-CEA) in 79 patients with primary lung cancer and in 78 persons as a comparison group including 32 patients with pulmonary tuberculosis, 23 patients with benign lung disease and 23 cases with healthy individual. Cyfra 21-1 is measured by a solid-phase immunoradiometric assay(CIS Bio International, France) based on the two-site sandwich method. SCC Ag is measured by a radioimmunoassay(Abbott Laboratories, USA). CEA is measured by a immunoradiometric assay(CIS Bio International, France). All data were expressed as the mean$\pm$standard deviation. Results: 1) The mean value of Cyfra 21-1 was $18.38{\pm}3.65\;ng/mL$ in the lung cancer and $1.l6{\pm}0.53\;ng/mL$ in the comparison group(p<0.0001). SCC Ag was $3.53{\pm}6.06\;ng/mL$ in the lung cancer and $1.19{\pm}0.5\;ng/mL$ in the comparison group(p<0.01). CEA was $35.03{\pm}13.9\;ng/mL$ in the lung cancer and $2.89{\pm}1.01\;ng/mL$ in the comparison group(p<0.0001). 2) Cyfra 21-1 level in squamous cell carcinoma($31.52{\pm}40.13\;ng/mL$) was higher than that in adenocarcinoma($2.41{\pm}1.34\;ng/mL$)(p<0.0001) and small cell carcinoma($2.15{\pm}2.05\;ng/mL$)(p=0.007). SCC Ag level in squamous cell carcinoma($5.1{\pm}7.68\;ng/mL$) was higher than that in adenocarcinoma($1.36{\pm}0.69\;ng/mL$)(p=0.009) and small cell carcinoma($1.1{\pm}0.24\;ng/mL$) (p=0.024). 3) The level of Cyfra 21-1 was not correlated with the progression of stage in squamous cell carcinoma of the lung. 4) Using the cut-off value of 3.3ng/mL, the diagnostic sensitivity of Cyfra 21-1 was 83% in squamous cell carcinoma, 22% in adenocarcinoma and 17% in small cell carcinoma. The sensitivity of SCC Ag and CEA were 39% and 20%, respectively in squamous cell carcinoma, 11% and 39% in adenocarcinoma, and 0% and 33% in small cell carcinoma. 5) Comparison of the receiver operating characteristics curves(ROC curve) for Cyfra 21-1, SCC Ag and CEA revealed that Cyfra 21-1 showed highest diagnostic sensitivity among them in the diagnosis of lung cancer. Conclusion: Cyfra 21-1 is thought to be a better tumor marker for the diagnosis of lung cancer than SCC Ag and CEA, especially in squamous cell carcinoma of the lung.

  • PDF