• Title/Summary/Keyword: Lab Shear Test

Search Result 66, Processing Time 0.022 seconds

Interfacial Shear Strength and Thermal Properties of Electron Beam-Treated Henequen Fibers Reinforced Unsaturated Polyester Composites

  • Pang Yansong;Cho Donghwan;Han Seong Ok;Park Won Ho
    • Macromolecular Research
    • /
    • v.13 no.5
    • /
    • pp.453-459
    • /
    • 2005
  • Natural fiber henequen/unsaturated polyester (UPE) composites were fabricated by means of a compression molding technique using chopped henequen fibers treated at various electron beam (EB) dosages. The interfacial shear strength (IFSS), dynamic mechanical properties, and thermal expansion behavior were investigated through a single fiber microbonding test, fractographic observation, dynamic mechanical analysis, and thermomechanical analysis, respectively. The results indicated that the interfacial and dynamic mechanical properties significantly depended on the level of the EB treatment irradiated onto the henequen fiber surfaces. The effect of EB treatment on the IFSS, storage modulus and fracture surface of the henequen/UPE composites agreed with each other. The results of this study also suggested that the modification of henequen fiber surfaces at 10 kGy EB is the most effective for improving the interfacial properties of the henequen/UPE composites.

Surface characteristics and bonding performance of polymer restorative materials for dental CAD/CAM systems (치과 캐드캠 시스템에서 사용되는 고분자 수복재료들의 표면특성과 접착양상)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.203-209
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the mechanical properties of polymer prosthetic and restorative materials for dental CAD/CAM using two test method; surface characteristics and shear bond strength. Methods: Commercialized CAD/CAM polymer blanks were investigated; One kinds of PMMA, and one PEKK blanks. A total of 20 PMMA and PEKK specimens were prepared, and each group was divided into 10 specimens. Average surface roughness was observed under surface profilometer. The contact angle was measured with a surface electrooptics. The bond strength was evaluated by a universal testing machine at a crosshead speed of 5mm/min. The data were statistically analyzed using independent t-test and Fisher's exact test(P<0.05). Results: The PMMA and PEKK group showed a significant difference in the shear bond strength with the composite resin(P<0.05). The surface roughness of the PEKK group was higher than that of the PMMA group. The fracture mode were observed in PEKK groups with 50% showing adhesive remnant index score. Conclusion: PEEK is used as substructure material and composite veneering material is applied. PEKK resins will contribute to the development of successful products that will provide structural and aesthetic satisfaction.

Comparison between Shear and Tensile Adhesion Strength of Cement for Ceramic Tiles and an Experimental Evaluation on the Cutting Effect of Tile for Tensile Adhesion Strength (타일 시멘트 전단접착강도와 인장부착강도 비교 및 인발부착강도 타일커팅 영향에 관한 실험적 평가)

  • Lee, Sang-Hyun;Ki, Jun-Do;Cho, Hong-Bum;Kim, Young-Sun;Moon, Hyung-Jae;Jeon, Hyun-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.181-182
    • /
    • 2021
  • Selecting a proper tile cement for ceramic tile is important to secure tile construction quality. But there is some ambiguity in standards about evaluating adhesion test such as using KS L 1593 in Lab test but using KS L 1592 in site. So, this study aims to how to select proper tile cement for securing adhesion strength in site considering both tensile and shear adhesion strength of cement for ceramic tile. Also, when doing tensile adhesion test in site, there may be adhesion drop because of cutting tile with grinder. As a result, drop of adhesion strength is about 9% ans quality manager consider these factor and should select proper tile cement.

  • PDF

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • v.32 no.4
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

Automotive Pre-primed Coatings with Automotive Structural Adhesive for Non-weldable Binding Process (자동차 구조용 접착제를 이용한 자동차용 Pre-primed 도료의 비용접식 접합공정 적용)

  • Moon, Je-Ik;Lee, Yong-Hee;Kim, Hyun-Joong;Noh, Seung Man;Nam, Joon Hyun;Kim, Min-Su;Kim, Jun-Ki;Kim, Jong-Hoon
    • Journal of Adhesion and Interface
    • /
    • v.12 no.3
    • /
    • pp.99-104
    • /
    • 2011
  • Currently, automotive pre-primed coatings has been developed to overcome environmental regulations and to reduce manufacturing cost in automotive industry. By these reasons, an automotive pre-primed system has been investigated to remove the wash and pre-treatment process using a roll coating application. It is required to develop non-weldable pre-primed system for automotive structural adhesives, because pre-primed sheet coated with organic compounds is hard to be assembled by welding process. Primer 1 (polyester type) and primer 2 (urethane type) were designed to satisfy flexibility and formability for non-weldable pre-primed system. According to the results of physical property test of the primers, adhesion test such as single-lap shear test and T-peel test, primer 1 (polyester type) had better physical properties such as pencil hardness, solvent resistance, flexibility and adhesion with automotive adhesive than that of primer 2 (polyurethane type). In addition, the possibility of the non-weldable pre-primed system was applicable to automotive assembly process in place of welding process.

Effect of Electron Beam Irradiation on the Interfacial and Thermal Properties of Henequen/Phenolic Biocomposites

  • Pang, Yansong;Yoon, Sung Bong;Seo, Jeong Min;Han, Seong Ok;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.6 no.4
    • /
    • pp.12-17
    • /
    • 2005
  • Natural fiber/phenolic biocomposites with chopped henequen fibers treated at various levels of electron beam irradiation (EBI) were made by means of a matched-die compression molding method. The interfacial property was explored in terms of interfacial shear strength measured by a single fiber microbonding test. The thermal properties were studied in terms of storage modulus, tan ${\delta}$, thermal expansion and thermal stability measured by dynamic mechanical analysis, thermomechanical analysis and thermogravimetric analysis, respectively. The result showed that the interfacial and thermal properties depend on the treatment level of EBI done to the henequen fiber surfaces. The present result also demonstrates that 10 kGy EBI is most preferable to physically modify the henequen fiber surfaces and then to improve the interfacial property of the biocomposite, supporting earlier results studied with henequen/poly (butylene succinate) and henequen/unsaturated polyester biocomposites.

  • PDF

Experimental study on variation in rheological properties of concrete subjected to pressure and shearing by pumping

  • Jung Soo Lee ;Kyong Pil Jang ;Chan Kyu Park ;Seung Hee Kwon
    • Advances in concrete construction
    • /
    • v.16 no.1
    • /
    • pp.59-68
    • /
    • 2023
  • In the pumping process, concrete moves along the pipe and experiences both pressure and shear. This changes the workability and flow characteristics of the concrete. However, the effect of pressure and shear on the change in properties of concrete during the pumping process has not yet been accurately identified. This study analyzed the effects of pressure and shear on the properties of concrete during pumping. For quantitative tests, lab-scale test equipment capable of simulating the pressure and shear applied to concrete during pumping was used. For one coarse aggregate type, two paste types, three mortar types, and five concrete types, the effects of pressure, shear, and shear under pressure conditions were examined by varying the maximum pressure (0 to 200 bar) and the rotational speed of the vane for shear (0 to 180 rpm). Under the maximum pressure condition of 200 bar, the water absorption of coarse aggregate increased by 0.62% and that of fine aggregate also increased. When the concrete was under pressure, significant changes (a reduction in a slump and an increase in viscosity and yield stress) compared with the effect of the elapsed time occurred owing to an increase in the water absorption of the aggregates. When both pressure and shear were applied to concrete, both the slump and viscosity decreased. As the rotational speed of the vane increased, changes in properties became significant. Shearing in the absence of pressure maintained the properties of concrete. However, shearing under pressure conditions caused a reduction in slump and viscosity.

Mechanical characteristics of CRM asphalt (CRM아스팔트의 바인더특성 분석)

  • Lee, Kyung ha
    • International Journal of Highway Engineering
    • /
    • v.2 no.1
    • /
    • pp.123-133
    • /
    • 2000
  • The asphalt mixture with CRM(Crumb Rubber Modifier) is known to show a better performance in resisting thermal cracking, fatigue cracking, and rutting compared with the conventional mixture. In this research, the lab tests on the physical and the mechanical characteristics of the domestic crumb rubber modified asphalt binder and conventional asphalts (AP-3, AP-5) were conducted. The physical test results show that CRM asphalt has better physical characteristics than that of conventional asphalts. The dynamic shear rheometer test results in high temperature show that CRM asphalt has higher complex shear modulus and aging resistance than those of conventional asphalts. And, the bending beam rheometer in low temperature test results show that CRM asphalt has higher resistance to thermal cracking than that of conventional asphalts.

  • PDF

The Characteristics of Undrained Shear Strength for Normally Consolidated Decomposed Weathered Mudstone Soil (정규압밀된 재성형 이암풍화토의 비배수 전단특성)

  • 김영수;김기영;문홍득
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.7-18
    • /
    • 2002
  • Generally, natural soils are affected by one-dimensional consolidation so that the behavior characteristic could be somewhat different from the isotropic consolidation specimen. But, due to experimental difficulties and the lack of equipment, the isotropic triaxial tests are mainly performed in most lab. tests. So it seems to be very effective if it is possible to predict pore water pressure and undrained shear strength in the $K_o$ state as the results of isotropic triaxial consolidation test. In this study, isotropic triaxial consolidation test and $K_o$ triaxial consolidation test were performed and we obtained parameters related to pore water pressure ratio using the Hyperbolic model. And then we predicted the behavior of pore water pressure that occurred in the $K_o$ state from the results obtained in the isotropic triaxial cosolidation test through the equation suggested by Lo(1969). It is possible to seize the validity of Lo(1969) equation. Also, considering undrained shear strength obtained from consolidation method in relation with water content, we find that consolidation method have an effect on undrained shear strength. Finally, using the Wroth(1984) equation that is based on the theory of critical state, undrained shear strength in the $K_o$ state was predicted from that of the isotropic triaxial consolidation test. The usefulness of the equation was verified by comparing the predicted value with experimental results.

A Study on Electrically Assisted Solid State Joining of Aluminum and Copper (알루미늄과 구리 간 통전고상접합 연구)

  • Park, J.W.;Choi, H.;Lee, S.;Jeong, H.J.;Hong, S.T.;Han, H.N.
    • Transactions of Materials Processing
    • /
    • v.29 no.1
    • /
    • pp.49-54
    • /
    • 2020
  • The influence of electric current on the joining properties of aluminum and copper was investigated. Various pulsed electric current conditions were set to the joining specimens followed by pressure. The shear strength of the joint area between aluminum and copper was measured by the lab shear test. In addition, the microstructures of the joint area were observed through a field emission scanning electron microscope, energy dispersive X-ray, and electron backscatter diffraction. The mechanical properties of each phase in the joint region were measured by nano-indentation. As a result, it was confirmed that electrically assisted solid state joining of copper and aluminum could be applied in various industrial fields.