• Title/Summary/Keyword: LV EF

Search Result 35, Processing Time 0.026 seconds

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

The Relationship of the LV Systolic Function, the LV Dimension and the LV Mass to QT Dispersion in Stable Angina Patients who are with or without Significant Coronary Stenosis (안정성협심증 환자에서 저명한 관상동맥 협착 유무와 좌심실 수축기능, 용적, 질량과 QT Dispersion 간의 관계)

  • Kwon, Jong-Bum;Yoon, Hee-Jeoung;Jin, Seung-Won;Her, Sung-Ho;Kim, Hyung-Doo;Kim, Kyung-Soo;Lee, Jong-Ho;Park, Khun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.439-446
    • /
    • 2008
  • Background: The aim of this study was to investigate the relationship of the left ventricular (LV) systolic function, the LV dimension and the LV mass with the QT dispersion in patients with stable angina, and we also wanted to compare this relationship between patients with and without significant coronary stenosis on coronary angiography. Material and Method: 174 patients complained of typical angina and they had no associated ST segment or cardiac enzyme abnormalities. The patients were divided into 2 groups based on the results of coronary angiography: the patients with angiographic coronary stenosis ${\geq}50%$ made up group I (n=101), and the patients with angiographic coronary stenosis <50% made up group II (n=73). An echocardiogram for assessing the LV ejection fraction (EF), the LV dimension and the LV mass and a 12.lead electrocardiogram for assessing the QT dispersion were performed before the coronary angiography. Result: The QT dispersion was significantly greater in group I than that in group II (39.8 ms vs. 33.3 ms; p<0.05). For all the patients, all the parameters of LV dimension and LV mass had statistically positive correlation to the QT dispersion, but the LV mass was the only independently significant parameter that was correlated with the increased QT dispersion (p<0.05). For group I, none of the echocardiographic parameters had significant correlation with the QT dispersion. However, the LV dimension and LV mass had significantly positive correlation with the QT dispersion, and the LV mass was also the only independently significant parameter that was correlated with increased QT dispersion in group II (p<0.05). Conclusion: Our study demonstrated a significantly positive correlation of the QT dispersion to the LV dimension and the LV mass in patients with stable angina. These findings are present only in patients without significant coronary stenosis.

Exercise Radionuclide Ventriculography in Patients with Mitral Stenosis (승모판 협착증 환자에서 운동부하 심장풀스캔을 이용한 좌심실기능의 평가)

  • Lee, Do-Yun;Shim, Won-Heum;Kim, Han-Soo;Park, Seung-Jung;Cho, Seung-Yun;Kim, Sung-Soon;Lee, Woong-Ku;Kim, Myeong-Jin;Choe, Kyu-Ok;Park, Chang-Yun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.58-64
    • /
    • 1992
  • We performed exercise radionuclide ventriculography to evaluate left ventricular (LV) function in 35 patients with pure mitral stenosis (MS). There were 6 males and 29 females ranging from 21 to 63 years of age (mean $37{\pm}10$ years). We also studied 8 healthy men as control group (mean age $27{\pm}5$ years). Each patients was evaluated at rest and during maximal exercise on an isokinetic bicycle ergometer. Peak filling rate (PFR), peak ejection rate (PER), ejection fracion (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and cardiac output (CO) were determined by the radionuclide technique. The results were summarized as follows: 1) LV systolic dysfunction and reduced PFR were noted in patients with MS. 2) EDV as well as SV decreased with exercise in patients with MS. 3) No significant increase in EF during exercise compared to rest value was observed because it was caused by reduced EDV and SV during exercise in patients with MS. 4) CO increased with exercise was significantly lower than normal in patients with MS. 5) Patients with MS were divided into two groups according to whether SF increased more than 5% druing exercise compared to resting state or decreased. Significant difference were found between these two groups. Patients with a fall in EF with exercise were older, had larger left atrial size, and had lesser decreased in ESV during exercise.

  • PDF

Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports

  • Gustavo Gavazzoni Blume;Luka David Lechinewski;Isabela Pedroza Vieira;Nadine Clausell;Giovana Paludo Bertinato;Paulo Andre Bispo Machado-Junior;Pedro Goulart Berro;Lidia Ana Zytynski Moura;Teresa Tsang
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.25-34
    • /
    • 2022
  • BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.

Evaluation of Cardiac Mechanical Dyssynchrony in Heart Failure Patients Using Current Echo-Doppler Modalities

  • Rehab M. Hamdy;Hend Osama;Hanaa M. Fereig
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.4
    • /
    • pp.307-319
    • /
    • 2022
  • BACKGROUND: Current guidelines indicate electrical dyssynchrony as the major criteria for selecting patients for cardiac resynchronization therapy, and 25-35% of patients exhibit unfavorable responses to cardiac resynchronization therapy (CRT). We aimed to evaluate different cardiac mechanical dyssynchrony parameters in heart failure patients using current echo-Doppler modalities and we analyzed their association with electrical dyssynchrony. METHODS: The study included 120 heart failure with reduced ejection fraction (HFrEF) who underwent assessments for left ventricular mechanical dyssynchrony (LVMD) and interventricular mechanical dyssynchrony (IVMD). RESULTS: Patients were classified according to QRS duration: group I with QRS < 120 ms, group II with QRS 120-149 ms, and group III with QRS ≥ 150 ms. Group III had significantly higher IVMD, LVMD indices, TS-SD speckle-tracking echocardiography (STE) 12 segments (standard deviation of time to peak longitudinal strain speckle tracking echocardiography in 12 LV-segments), and LVMD score compared with group I and group II. Group II and group III were classified according to QRS morphology into left bundle branch block (LBBB) and non-LBBB subgroups. LVMD score, TS-SD 12 TDI, and TS-SD 12 STE had good correlations with QRS duration. CONCLUSIONS: HFrEF patients with wide QRS duration (> 150 ms) had more evident LVMD compared with patients with narrow or intermediate QRS. Those patients with intermediate QRS duration (120-150 ms) had substantial LVMD assessed by both TDI and 2D STE, regardless of QRS morphology. Subsequently, we suggest that LVMD indices might be employed as additive criteria to predict CRT response in that patient subgroup. Electrical and mechanical dyssynchrony were strongly correlated in HFrEF patients.

Phase Image Analysis in Conduction Disturbance Patients (심실내 전도장애 환자에서의 $^{99m}Tc$-RBC Gated Blood-Pool Scintigraphy을 통한 Phase Image Analysis)

  • Kwak, Byeng-Su;Choi, Si-Wan;Kang, Seung-Sik;Park, Ki-Nam;Lee, Kang-Wook;Jeon, Eun-Seok;Park, Chong-Hun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 1994
  • It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of it's events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of $^{99m}Tc$-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls ($44.4{\pm}13.9%$ vs $69.9{\pm}4.2%,\;2.48{\pm}0.98$ vs $3.51{\pm}0.62,\;1.76{\pm}0.71$ vs $3.38{\pm}0.92$, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls ($20.6{\pm}18.1$ vs $8.6{\pm}1.8,\;22.5{\pm}9.2$ vs $16.0{\pm}3.9,\;95.7{\pm}31.7$ vs $51.3{\pm}5.4$, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the Wolff-parkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls ($10.6{\pm}2.6$ vs $8.6{\pm}1.8$, p<0.05, $69.8{\pm}11.7$ vs $51.3{\pm}5.4$, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventricles in patients with normal conduction, but markedly delayed phase in the left ventricle of patients with LBBB. 6) In 13 cases of WPW syndrome, the site of preexcitation could be localized in 10 cases (77%) by phase image analysis. Therefore, it can be concluded that phase image analysis can provide an accurate noninvasive method to detect the mechanical consequences of a wide variety of abnormal electrical activation in ventricles.

  • PDF

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Postoperative Left Ventricular Dynsfunction in Adult PDA (성인 동맥관 개존증 수술 후 좌심실 기능 저하의 위험 인자 분석)

  • 윤태진
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.785-791
    • /
    • 2000
  • Left ventricular dysfuction is common in immediate postoperative periods after surgical correction of heart diseases with chronic left ventricular volume overload. We speculated postoperative changes of left ventricular volume and unction in patients with patent ductus osus(PDA) who had underwent surgical repair at ages older than 16 years. Factors influencing postoperative left ventricular volume and function were also analyzed. Material and Method: From August 1989 to August 1999 thirty-siz adult patients with PDA 28 females and 8 males. were enrolled in this study. Their age ranged from 16 years to 57 years(mean :32 years). Types of surgical repair were division with primary closure in 22, division with patch closure in 6, internal obliteration using cardiopulmonary bypass in 4 and ligation in 4. Aortic clamping was combined during surgical repair in 22(61%) and cardiopulmonary bypass was used in 8(22%) Two-dimensional echocardiography studies were performed in 34(94%) preoperatively and in 25(66%) immediate postoperatively to assess postoperative changes of left ventricular internal dimensions. left ventricular volume and ejection fraction. Duration of postoperative follow-up ranged from 1 month to 99 months (mean:22 months) and 10 patients underwent 16 echocardiographic evaluation during this period Result : Preoperative and postoperative left ventricular systolic dimensions(LVIDs) were 42$\pm$8.0mm and 42$\pm$8.3mm left ventricular diastolic dimensions(LVIDd) were 64$\pm$10.0mm and 56$\pm$7.4mm left ventricular end systolic volumes(LVESV) were 62$\pm$19cc (z=1.87$\pm$0.06) and 59$\pm$24cc(z=1.78$\pm$0.08) left ventricular end diastolic volumes(LVEDL) were 169$\pm$40cc(z-1.17$\pm$0.1) and 112$\pm$29cc(z=0.85$\pm$0.1) and ejection fractions(EF) were 66$\pm$6.7% and 48$\pm$12.6% respectively. There were statistically significant differences between preoperative and postoperative values in LVDIDd(p=0.001) LVEDV(p=0.001) and EF(p=0.0001) while no significant difference is LVIDs and LVESV. Postoperative depression of ejcection fraction was significantly related with z-score of preoperative LVESV and LVEDV by univariateanalysis while LVEDV only was significant risk factor for postoperative LV dysfunction by multiple regressioin analysis ($\Delta$LVEF=-13.3-4.62$\times$LVEDV(z), p=0.001) During the follow-up periods ejection fractions become normalized in all except one patients. Conclusion ; Left ventricular function is usually deteriorated after the surgical correction of PDA in adult age and preoperative LVEDV is a major determinant of postoperative LV function.

  • PDF