• Title/Summary/Keyword: LUTS

Search Result 85, Processing Time 0.028 seconds

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

A Threshold Controller for FAST Hardware Accelerator (FAST 하드웨어 가속기를 위한 임계값 제어기)

  • Kim, Taek-Kyu;Suh, Yong-Suk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.187-192
    • /
    • 2014
  • Various researches are performed to extract significant features from continuous images. The FAST algorithm has the simple structure for arithmetic operation and it is easy to extraction the features in real time. For this reason, the FPGA based hardware accelerator is implemented and widely applied for the FAST algorithm. The hardware accelerator needs the threshold to extract the features from images. The threshold is influenced not only the number of extracted features but also the total execution time. Therefore, the way of threshold control is important to stabilize the total execution time and to extract features as much as possible. In order to control the threshold, this paper proposes the PI controller. The function and performance for the proposed PI controller are verified by using test images and the PI control logic is designed based on Xilinx Vertex IV FPGA. The proposed scheme can be implemented by adding 47 Flip Flops, 146 LUTs, and 91 Slices to the FAST hardware accelerator. This proposed approach only occupies 2.1% of Flip Flop, 4.4% of LUTs, and 4.5% of Slices and can be regarded as a small portion of hardware cost.

Implementation of Uroflow and Urophonography Analysis System for LUTS Diagnosis (하부요로증상 진단을 위한 요속 및 요류음 분석 시스템 구현)

  • Jeon, Gye-Rok;Jeong, Do-Un
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.302-309
    • /
    • 2010
  • The present study proposed a method of measuring uroflow and urophonography at the same time for more accurate diagnosis in case uroflow looks normal due to compensatory function hypertrophy in the expression of early obstruction. In case of early obstruction, there happens turbulent uroflow by the obstruction even if the uroflow looks normal and thus obstruction can be detected by measuring and analyzing signal caused by turbulent flow. We implemented a system that can measure both uroflow and urophonography, and evaluated its performance. In the experiment, we observed changes in uroflow and urophonography according to artificial pressure and the degree of obstruction, and confirmed that it is possible to determine the effect of compensatory function hypertrophy by analyzing urophonographyic parameter under the same uroflow. The results of our experiment show that the effect of compensatory function hypertrophy in the early-stage obstruction of lower urinary tract, which is not detectible with uroflowmetry alone, can be assessed through urophonographic analysis.

Sacral Acupuncture for Lower Urinary Tract Symptoms: A Systematic Review of Randomized Controlled Trials

  • Park, Jiwon;Chun, Se-Eun;Park, Min-Cheol;Jo, Eun-Heui
    • Journal of Acupuncture Research
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Lower urinary tract symptoms (LUTS) associated with storage, voiding, and post-micturition reduce quality of life and cause mental health problems. In traditional medicine, Baliao points have been empirically used to treat urinary system diseases. In this review, randomized controlled trials (RCTs) using sacral acupuncture on Baliao points with sham treatment, other remedies, or other acupoints were retrieved from 8 electronic databases up to June 2021. Sixteen RCTs met the inclusion criteria. The quality of the included studies was assessed using a risk-of-bias (ROB) tool. Most of the evaluation indicators used in the included RCTs showed that sacral acupuncture had a significant therapeutic effect compared with the sham control intervention groups, and other remedies. However, all studies using acupoints (other than the Baliao points) as a control intervention had a "high" ROB and only reported secondary processed information, making it difficult to evaluate the efficacy of sacral acupuncture treatment for LUTS. No serious adverse effects were reported for sacral acupuncture, and only a low number of minor side effects were observed. These results suggest that sacral acupuncture could be considered as an alternative to existing treatments, with the added benefit of low cost. Large-scale, long-term RCTs are required in the future.

Analysis and Compensation of RF Path Imbalance in LINC System (LINC 전력 증폭기의 경로 오차 영향 분석 및 보상에 관한 연구)

  • Lim, Jong-Gyun;Kang, Won-Shil;Ku, Hyun-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.8
    • /
    • pp.857-864
    • /
    • 2010
  • In this paper, we analyse the effect of the path imbalances(gain and phase mismatches) in LINC(LInear amplification with Nonlinear Component) system, and propose a simple scheme using LUTs(Look Up Table) to compensate the path imbalances. The EVM(Error Vector Magnitude) and ACPR(Adjacent Channel Power Ratio) of the LINC system are degraded significantly by the path imbalances because it adopts an outphasing technique. The EVM and ACPR are theoretically extracted for two variables(gain and phase mismatch factors) and 2-D LUTs for those are generated based on the analysis. The efficient and simple compensation scheme for the path imbalances is proposed using the 2-D LUTs. A LINC system with the suggested compensation scheme is implemented, and the proposed method is verified with an experiment. A 16-QAM signal with 1.5 MHz bandwidth is used. Before the compensation, the path gain ratio was 95 % and phase error was $19.33^{\circ}$. The proposed scheme adjusts those values with 99 % and $0.5^{\circ}$, and improves ACPR about 18.1 dB.

Cumulative Probability of Prostate Cancer Detection Using the International Prostate Symptom Score in a Prostate-specific Antigen-based Population Screening Program in Japan

  • Kitagawa, Yasuhide;Urata, Satoko;Narimoto, Kazutaka;Nakagawa, Tomomi;Izumi, Kouji;Kadono, Yoshifumi;Konaka, Hiroyuki;Mizokami, Atsushi;Namiki, Mikio
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7079-7083
    • /
    • 2014
  • The International Prostate Symptom Score (IPSS) is often used as an interview sheet for assessing lower urinary tract symptoms (LUTS) at the time of prostate-specific antigen (PSA) testing during population-based screening for prostate cancer. However, the relationship between prostate cancer detection and LUTS status remains controversial. To elucidate this relationship, the cumulative probability of prostate cancer detection using IPSS in biopsy samples from patients categorized by serum PSA levels was investigated. The clinical characteristics of prostate cancer detected using IPSS during screening were also investigated. A total of 1,739 men aged 54-75 years with elevated serum PSA levels who completed the IPSS questionnaire during the initial population screening in Kanazawa City, Japan and underwent systematic transrectal ultrasonography-guided prostate biopsy between 2000 and 2013 were enrolled in the present study. Of the 1,739 men, 544 (31.3%) were diagnosed with prostate cancer during the observation period. The probability of cancer detection at 3 years in the entire study population was 27.4% and 32.7% for men with $IPSS{\leq}7$ and those with $IPSS{\geq}8$, respectively; there was no statistically significant difference between groups. In men with serum PSA levels of 6.1 to 12.0ng/mL at initial screening, the probability of cancer detection was significantly higher in men with $IPSS{\leq}7$ than in those with $IPSS{\geq}8$. There were no significant differences in clinical characteristics between groups of patients stratified by IPSS. These findings indicate that the use of IPSS for LUTS status evaluation may be useful for prostate cancer detection in the limited range of serum PSA levels.

Logic Synthesis for LUT-Type FPGA Using Pattern Extraction (패턴 추출을 이용한 LUT형 FPGA 합성)

  • 장준영;이귀상
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.787-790
    • /
    • 1998
  • In this paper, we presents a method for multi-level logic mainmization which is suitable for the minimization of look-up table type FPGAs. A pattern extraction algorithm is minimized AND/XOR multi-level circuits. The circuits apply to Roth-Karp decomposition which is most commonly used technique in the FPGA technology mapping. We tested the FPGA synthesis method using pattern extraction on a set of benchmark. The proposed method achieved reductions on the number of LUTs in mapping soultion as compared with MISII(or SIS) or previous results〔5〕

  • PDF

Association between Metabolic Syndrome and Lower Urinary Tract Symptoms, Prostate Specific Antigen, and Prostate Volume: Single C enter Study (대사증후군과 하부요로증상, PSA 및 전립샘 용적과의 연관성 : 단일기관 연구)

  • Kang, Jung Hun;Kim, Yon-Min;Jeong, Jeongyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.313-319
    • /
    • 2018
  • The purpose of this study was to investigate the influence of metabolic syndrome (MS) on the lower urinary tract symptoms (LUTS), prostate specific antigen (PSA), and prostate volume in Korean men. We analyzed the data from 2654 men over the age of 40 who visited our health promotion center for regular health checkups. Of the total 2654 men, mean age, PSA level, International Prostate Symptom Score (IPSS), and prostate volume were 54.6 years, 1.21ng/ml, 6.2 points, and 27.8ml, respectively. All examinees were divided into MS group (46.5%, 1235 men) and non-MS group (53.5%, 1419). Age and prostate volume were significantly higher in the MS group. The patients were divided into three groups according to their ages: 40's, 50's, and over 60 years old. Prostate volume of the MS group in the younger age groups (40-49 years and 50-59 years) was significantly larger than that of the non-MS group. However, no difference was revealed in the age group of 60-69 years. No significant differences were found in the PSA level and LUTS between the MS and non-MS groups. In the multivariate regression analysis, central obesity was the strongest risk factor for the enlargement of prostate over 30ml among the metabolic components.

FPGA Implementation of Extreme Contour Point Algorithm to detect rotated angle of High Definition Image (고해상 영상의 회전된 각도를 검출하기 위한 Extreme Contour Point 알고리즘의 FPGA 설계)

  • Jeong, Min-woo;Pack, Chan-su;Kim, Hi-Seok
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.344-350
    • /
    • 2016
  • In this Paper, we propose an optimized method of hardware design based on Field Programmable Gate Array (FPGA) to detect rotated angle of high definition image about Extreme Contour Point (ECP) algorithm with moving video image could be not happened to translation motion, but also physical rotation motion. It was evaluated by XC7Z020 xc7z020-3clg400 FPGA board by using xilinx 14.2 tool. The much well-known method, the Coordinate Rotation Digital Integrated Computation (CORDIC) is an algorithm to estimate rotated angle between point and point. Through the result both ECP and CORDIC, our proposed design are confirmed to have similar operating speed of about 4ns with CORDIC. However, it is verified to have high performance result in terms of the hardware cost, is much better than CORDIC with cost reduction of registers and Look Up Tables (LUTs) of 108% and 91%, respectively.

Implementation of a backend system for real-time intravascular ultrasound imaging (실시간 혈관내초음파 영상을 위한 후단부 시스템 구현)

  • Park, Jun-Won;Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.215-222
    • /
    • 2018
  • This paper reports the development and performance evaluation of a backend system for real-time IVUS (Intravascular Ultrasound) imaging. The developed backend system was designed to minimize the amount of logic and memory usage by means of efficient LUTs (Look-up Tables), and it was implemented in a single FPGA (Field Programmable Gate Array) without using external memory. This makes it possible to implement the backend system that is less expensive, smaller, and lighter. The accuracy of the backend system implemented was evaluated by comparing the output of the FPGA with the result computed using a MATLAB program implemented in the same way as the VHDL (VHSIC Hardware Description Language) code. Based on the result of ex-vivo experiment using rabbit artery, the developed backend system was found to be suitable for real-time intravascular ultrasound imaging.