• Title/Summary/Keyword: LTD 엔진

Search Result 226, Processing Time 0.021 seconds

Development and performance evaluation of the porous tube dilutor for real-time measurements of fine particles from high humidity environments (고수분 환경에서 미세먼지 실시간 측정을 위한 다공 튜브형 희석장치의 개발 및 성능 평가)

  • Woo, Chang Gyu;Hong, Ki-Jung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;An, Jeongeun;Kang, Su Ji;Chun, Sung-Nam
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Real-time measurements of fine particles from stack emission gases are necessary due to the needs of continuous environmental monitoring of PM10 and PM2.5. The porous tube dilutor using hot and cold dilutions was developed to measure fine particles without condensable particles from highly humid emission gases and compared to the commercialized ejector-type dilutor. Particle size distributions were measured at the emission gases from a diesel engine and a coal-fired boiler. The porous tube dilutor could successfully measure the accumulation mode particles including relatively large particles more than $3{\mu}m$ without nuclei particles, while the ejector dilutor detected some condensable particles and could not detect large particles. The porous tube dilutor could successfully remove the already condensed water droplet particles generated by a humidifier in a $30m^3$ chamber.

A Study of Multi Hull Form Design for Small Leisure Fishing Vessels (소형 레저어선의 다동체 선형설계 연구)

  • Lee Seung-Hee;Lee Young-Gill;Kang Dae-Sun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.2
    • /
    • pp.98-108
    • /
    • 2006
  • The vessels, already built and is operating in Korea, have the hull form of catamaran, with LOA(Length Over All) 15 m, LBP(Length Between Perpendiculars) 12 m, GT(Gross Tonnage) 9.77ton, Light Load Displacement 15.1ton. Korean Society of Ship Inspection & Technology, Chungnam National University, Inha University, Seoul National University and Advance Marine Tech co. ltd developed by cooperation it for fishing vessels. And it used FRP(Fiber Reinforced Plastics) for hull material and main engine of diesel $360ps{\times}2800rpm{\times}2sets$ with a water jet system. Based on these results, this paper describe small leisure fishing vessels with multi-hull, in relation to the project of CTYS(Regional Reserch Center for Transportation System of Yellow Sea Inha University) that aimed to development of trimaran hull form(LOA=17m, LBP=14m(Side Hull=6m), GT=9.77ton, Light Weight=11.2 ton).

  • PDF

Effect of Process Parameters on Quality in Joint for Al/Steel Joining a MPW (전자기 펄스 용접을 이용한 Al/Steel 접합시 접합부 품질에 미치는 공정변수 영향)

  • Shim, Ji-Yeon;Kang, Bong-Yong;Kim, Ill-Soo;Park, Dong-Hwan;Kim, In-Ju;Lee, Kwang-Jin
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.27-27
    • /
    • 2009
  • 드라이브 샤프트는 일반적으로 엔진에서 발생된 회전력을 바퀴에 직접 전달하는 동시에 조향기능을 수행하는 자동차 부품이다. 최근에 경량화를 통한 에너지 절감을 위하여 기존 스틸소재를 알루미늄으로 대체하는 방안에 대한 연구가 집중되고 있다. 그러나 알루미늄 단일소재로 드라이브 샤프트를 제조하는 것은 비경제적이며 또한 기 개발된 자동차 부품들과의 연결을 고려하여 알루미늄 튜브와 스틸 요크의 이종금속 접합기술이 요구된다. 전자기 펄스용접은 전자기력을 이용하여 용접대상물을 고속으로 충돌시켜 용접하는 기술로서 열 발생이 적어 재료의 특성차로 인한 결함 및 변형이 발생하지 않아, 이종금속간 고품질 용접이 가능하며, 전자기 펄스 용접부의 품질과 밀접한 관계를 갖는 공정변수 경우 모재와 접합재의 재질 따라 적정 공정변수 범위가 변화되므로 공정에 따른 데이터의 축적은 대단히 중요하다. 전자기 펄스 용접을 이용한 이종금속 접합시 접합부 품질에 영향을 미치는 공정변수는 충전전압, 모재와 접합재 사이의 간격 및 접합재의 직경과 두께의 비(D/T비)로서 보고되었으며, Al/Steel 이종 금속 접합시 이들 공정변수가 접합부에 미치는 영향 및 최적의 공정변수 도출을 위한 연구는 시도되지 않았다. 따라서 본 연구는 전자기 펄스 용접기술을 이용한 Al/Steel 이종금속 접합 실험을 통하여 전자기 펄스용접의 적정성과 최적의 충전전압, 모재와 접합재 사이의 간격, D/T비를 도출하고자 한다. 전자기 펄스 용접 장치는 한국생산기술연구원과 웰메이트(주)에서 공동으로 개발한 $120{\mu}F$의 캐패시터 6개로 구성된 'W-MPW36'을 사용하였으며 이 장치의 최대충전전압과 최대접합용량은 각각 10kV, 36kJ이다. 접합재는 전기 전도율의 높은 Al 1070 파이프를 사용하였으며 모재는 기존 스틸 요크재인 SM45C 환봉을 사용하였다. 기보고된 연구를 통하여 코일과 접합재 사이의 간격이 좁을수록 높은 전자기력이 접합재에 작용하는 것을 확인하였으나 코일내 접합재와 모재 삽입 편의를 위하여 1mm로 설정하였다. 접합부의 품질 평가를 위하여 수압시험을 실시하였으며, 시험 후 접합부 단면을 주사전자현미경(SEM)을 이용하여 관찰하였다.

  • PDF

Shape Optimization of Three-Way Reversing Valve for Cavitation Reduction (3 방향 절환밸브의 공동현상 저감을 위한 형상최적화)

  • Lee, Myeong Gon;Lim, Cha Suk;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1123-1129
    • /
    • 2015
  • A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time-consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively.

Analysis of Two-Way Fluid-Structure Interaction and Local Material Properties of Brazed Joints for Estimation of Mechanical Integrity (관형 열교환기의 기계적 건전성 확보를 위한 유체-고체 연성해석과 브레이징 접합부의 국부적 물성분포 분석)

  • Kang, Seok Hoon;Park, Sang Hu;Min, June Kee;Jeong, Ho Sung;Son, Chang Min;Ha, Man-Young;Cho, JongRae;Kim, Hyun Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.9-16
    • /
    • 2013
  • Recent years have witnessed a strong need for eco-friendly and energy-efficient systems owing to global environmental problems. A heat exchanger is a well-known mechanical rig that has long been used in many energy systems. The use of a heat exchanger in an airplane engine has been attempted. In this case, the heat exchanger should be redesigned to be compact, lightweight, and highly reliable, and the issue of mechanical integrity gains importance. Therefore, in this study, we proposed a method for evaluating the mechanical integrity of a tube-type heat exchanger. A U-shaped single tube was used as an example, and its behavior and stress distribution were studied using fluid-structure interaction (FSI) analysis.

Optimal Gas Detection System in Cargo Compressor Room of Gas Fueled LNG Carrier (가스추진 LNG 운반선의 가스 압축기실에 설치된 가스검출장치의 최적 배치에 관한 연구)

  • Lee, Sang-Won;Shao, Yude;Lee, Seung-Hun;Lee, Jin-Uk;Jeong, Eun-Seok;Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.617-626
    • /
    • 2019
  • This study analyzes the optimal location of gas detectors through the gas dispersion in a cargo compressor room of a 174K LNG carrier equipped with high-pressure cargo handling equipment; in addition, we propose a reasonable method for determining the safety regulations specified in the new International Code of the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk (IGC). To conduct an LNG gas dispersion simulation in the cargo compressor room-equipped with an ME-GI engine-of a 174 K LNG carrier, the geometry of the room as well as the equipment and piping, are designed using the same 3D size at a 1-to-1 scale. Scenarios for a gas leak were examined under high pressure of 305 bar and low pressure of 1 bar. The pinhole sizes for high pressure are 4.5, 5.0, and 5.6mm, and for low pressure are 100 and 140 mm. The results demonstrate that the cargo compressor room will not pose a serious risk with respect to the flammable gas concentration as verified by a ventilation assessment for a 5.6 mm pinhole for a high-pressure leak under gas rupture conditions, and a low-pressure leak of 100 and 140 mm with different pinhole sizes. However, it was confirmed that the actual location of the gas detection sensors in a cargo compressor room, according to the new IGC code, should be moved to other points, and an analysis of the virtual monitor points through a computational fluid dynamics (CFD) simulation.