• 제목/요약/키워드: LSI(Langelier Saturation Index)

검색결과 6건 처리시간 0.02초

상수도관로의 부식 방지를 위한 수돗물의 침식성 평가 (Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System)

  • 곽필재;이현동;남상호
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

수질안정화 약품 주입에 따른 상수도관 내부 부식제어 특성 연구 (Corrosion control technique for pipeline system through injecting water stabilizer)

  • 황병기;우달식
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.545-551
    • /
    • 2011
  • 최근 고품질의 수돗물에 대한 소비자의 요구가 상승함에 따라 상수도 배급수관의 내부 부식에 의한 수질악화 및 부식제어 연구에 대한 관심이 높아지고 있다. 이에 따라 노후 관 교체 사업을 대신하여 수질 관리를 위한 부식 제어 수단을 강구하지 않고서는 근본적인 문제 해결이 이루어질 수 없는 실정이다. 본 연구에서는 수질안정화 약품 주입에 의한 상수도관 내부 부식제어 효율을 평가하기 위해 Pilot Plant 실험을 실시하였으며, 부식성제어 효율은 물의 부식성을 나타내는 LSI(Langelier Saturation Index)값에 의해 평가되었다. 실험결과, Pilot Plant에 의해 제조된 반응수는 수질안정화 약품인 액상소석회($Ca(OH)_2$, liquid lime)의 주입으로 부식성이 개선되어 철 용출이 억제되는 효과가 확인되었다. 강관과 동관을 절단하여 제작한 시편의 부식도 측정을 통해 각각 35.4, 44.5%의 부식제어 효과가 있음을 확인하였고 수질안정화 약품이 주입된 Sample관이 더 두터운 부식 생성물 층을 갖고 있는 것으로 밝혀졌으며, 결과적으로 수질안정화 약품을 투입한 배관이 부식 방지 측면에서 안정한 수질을 갖고 있음을 알 수 있었다.

정수처리에서 pH 저감에 의한 응집효율향상에 관한 연구 (Improving Coagulation Performance with pH Preadjustment in Drinking Water Treatment)

  • 이환;이철효;정창규;이윤진
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2003
  • This paper reports on a pilot scale comparison of PACS coagulation with and without pH preadjustment. The pH of the water was adjusted with carbon dioxide and sulfuric acid. Process performance was assessed on the basis of total organic carbon(TOC), UV absorbance, turbidity and disinfection by-product(DBP) precursors. Coagulation pH appeared to be a determining factor for maximum NOM removal. The optimum coagulation pH in order to decrease TOC and turbidity were pH 7. Preadjustment of pH 7 increased TOC removal to as much as 43, 47 percent with sulfuric acid and carbon dioxide. Moreover, coagulation at pH 7 caused a reduction in UV$_{254}$, THMFP and HAAFP compared to the baseline coagulation. For preadjustment of pH 7 with carbon dioxide, the percentage of TOC, UV$_{254}$, THMFP and HAAFP shows the reduction rate of 3.8, 0.5, 4.8, 9.4% comparing to the coagulation rendition using sulfuric acid. Acid addition to depress pH during coagulation decrease Langelier Saturation Index(LSI), potentially causing increase corrosion in water distribution systems. LSI for carbon dioxide and sulfuric acid at pH 6 was -2.3, -3.3. Therefore, carbon dioxide was more effective at controlling corrosion than sulfuric acid.

수돗물의 pH가 동관의 부식에 미치는 영향 (The Influence of pH on Corrosion Behavior of Copper Tubes in Tap Water)

  • 민성기;나승찬;황운석
    • Corrosion Science and Technology
    • /
    • 제8권6호
    • /
    • pp.232-237
    • /
    • 2009
  • Copper tubes are widely used in the distribution systems of drinking water throughout the world because of their excellent corrosion resistance, high thermal conductivity, and ease of fabrication. However, corrosion problems from copper tubes as blue water phenomenon and leakage have been reported appreciably. The effect of pH on the corrosion behavior of copper tube for tap water was investigated by electrochemical voltammetric techniques in synthetic tap water. And the copper corrosion cases were discussed from the viewpoint of factors affecting the corrosion rate such as pH, alkalinity, LSI(Langelier Saturation Index), and concentration of bicarbonate and dissolved carbon dioxide.

SWRO 생산수의 부식성 제어를 위한 목표 수질 연구 및 소규모 Pilot Plant 적용 (Corrosive control of the water produced by SWRO and Application to small dimensional Pilot Plant)

  • 김민철;황규원;우달식;윤석민;문정기;곽명화
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.1042-1045
    • /
    • 2009
  • 역삼투식 해수담수화 (Sea Water Reverse Osmosis, SWRO) 공정에 의한 생산수는 pH가 낮고, 해수 내 존재하는 경도성분인 Ca, Mg 이온이 대부분 제거되기 때문에 상대적으로 매우 강한 부식성을 지니고 있다. 이를 음용수 및 공업용수로 이용 시 설비 및 배관계통에 심각한 부식문제를 유발할 수 있으며, 이를 방지하기 위한 처리공정과 부식성 제어 기술의 지속적인 개발이 요구되는 실정이다. SWRO 1단으로 처리 시 생산수의 전기전도도는 $150{\mu}S/cm$ 정도의 범위를 보이며, 2단 SWRO 과정을 거칠 시 전기전도도는 $100{\mu}S/cm$ 이하의 범위를 나타내는 것으로 알려져 있다. 본 연구에서는 SWRO 2단 처리수를 가정한 $20{\mu}S/cm{\sim}25{\mu}S/cm$ 범위의 전기전도도를 지닌 물을 실험 원수로 사용하여, 기존 방식제의 성분과 생산수의 특성을 고려한 효율적인 알칼리성 수처리제를 적용하고 그에 대한 부식성 제어 연구를 수행하였다. SWRO 생산수를 대상으로 부식방지기술을 개발하기 위해서는 부식제어와 관련된 수질 인자인 pH, 칼슘경도, 알칼리도의 조절과 LSI(Langelier Saturation Index)를 설정하는 것이 무엇보다도 중요하다. 본 연구에서는 해수담수화 공정의 생산수를 음용수 및 공업용수로 이용하기 위한 목표 수질을 pH 7.5~7.8, LSI 0 이상, 부가적으로 전기전도도는 $250{\mu}S/cm$ 이하로 설정하였으며, 연구목표 수질을 달성할 수 있는 부식억제제 및 알칼리성 수처리제의 적용을 통해 목표 수질에 대한 설정 근거를 마련하고자 하였다.

  • PDF

액상소석회를 이용한 SWRO 생산수의 부식제어 연구 (Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime)

  • 김민철;황규원;우달식;윤석민;곽명화
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.529-536
    • /
    • 2011
  • 본 연구는 수돗물과 SWRO 생산수의 수질 특성을 분석하여 SWRO 생산수가 지닌 강한 부식성을 확인하였으며, 이를 근거로 해수담수화 시설의 유지관리 및 부식제어를 목표로 진행되었다. 연구 초기 과정에서는 철 시편(mild steel coupon)에 대한 회분식 실험(Batch test)과 전기화학 실험을 통해 수돗물과 SWRO 생산수의 부식성을 비교하였다. SWRO 생산수의 부식성 제어를 위한 수단으로써 액상소석회(liquid lime, $Ca(OH)_2$)와 이산화탄소(Carbon Dioxide, $CO_2$)를 주입하는 방법과 액상소석회와 인산염계 부식억제제(Phosphate Corrosion Inhibitor, $P_2O_5$)의 조합에 이산화탄소를 주입하는 두 가지 방법을 비교하였다. 실험을 통한 각 수질의 평가는 부식성 평가 지수인 LSI(Langelier Saturation Index)를 통해 비교하였고 그 결과를 통해 액상소석회와 인산염계 부식억제제의 최적 주입량을 선정하여 모의배관 실험(Loop system test)에 적용하였다. 모의배관 운전 평가 후 장착된 금속배관(steel pipe)은 내부의 스케일에 대한 기기분석(SEM, EDX, XRD) 평가를 수행하여 형성물의 주성분과 산화상 및 원소 함류량을 비교 할 수 있었다. 실험 결과, SWRO 생산수에 부식제어기술을 적용하지 않은 대조군과 비교하여 적정량의 단일 액상소석회를 주입한 경우 평균 97.4%의 높은 부식억제 효과를 나타내었고, 액상소석회 와 부식억제제 조합이 주입된 경우 평균 90.9%의 부식억제 효과를 나타냈다. 모의배관 실험 과정 중 금속배관 내부에 형성된 스케일은 대조군의 경우 주로 철 산화물인 반면, 실험군의 경우 탄산칼슘($CaCO_3$) 피막이 형성되어 부식방지에 효과적임을 확인하였다.