• Title/Summary/Keyword: LR-test

Search Result 108, Processing Time 0.027 seconds

Analysis of DITI, HRV about the Effect of Far Infrared Radiation Applied to Whole Body('On-tong Therapy') (전신 원적외선 조사요법(온통요법(溫通療法))의 치료 효과에 대한 적외선 체열 분포와 심박변이도 검사 분석)

  • Kim, Min-Young;Ahn, Ji-Yoon;Choi, Seok-Young;Hwang, Deok-Sang;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.94-106
    • /
    • 2013
  • Objectives: The purpose of this study is to find the effect of Far Infrared Radiation (FIR) about improvement of chief complaints and health state. Methods: For this study we evaluated thermographic images, heart rate variability (HRV), visual analogue scale (VAS) score of 34 patients with various diseases. Tests were done two times, before and after treatments and we compared the test results. We used the temperature difference between CV12 and CV4, both sides of PC8, LR3 for recognizing improvement of blood circulation. We analyzed the change of complexity, stability of autonomic nervous system (ANS) by HRV test. The patients were asked to fill out questionnaire about the severity of symptoms by VAS score. Analyses were undertaken using SPSS ver.12.0.1 and p-value of < 0.05 was considered significant. Results: Statistical analysis shows that Far Infrared Radiation (FIR) had significant efficiency in increasing surface temperature and reducing VAS pain scores. In heart rate variability (HRV) test, LF/HF ratio showed tends to improve. Conclusions: The application of an FIR to whole body appears to alleviate various complaints of patients.

A sham moxibustion device and Masking test (가짜뜸 개발 및 Masking test)

  • Park, Ji-Eun;Han, Chang-Hyun;Kang, Kyung-Won;Shin, Mi-Suk;Oh, Dal-Seok;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.1 s.19
    • /
    • pp.93-100
    • /
    • 2007
  • TObjectives: Develop a sham moxibustion and determine whether subjects can distinguish a sham moxibustion from a real moxibustion. Design: Single-blinded, randomized, placebo-controlled clinical trial Methods: Sham and real moxibustion resemble each other in appearance, burning procedure, but the base of the sham moxibustion isolates the moxa-producing heat and smoke. This device was tested in a clinical trial in which subjects received moxibustion at Zhongwan(CV12), Mingmen(GV4), Quchi(LI11), Zusanli(ST36), Taichong(LR3)), Hegu(LI4). Volunteers(n=32) were given pre-treatment questionnaire to assess their experience in getting moxibustion therapy and performing it. They randomized into treatment(n=16) or sham controlled group(n=16), received moxibustion according their groups. After treatments, the effectiveness of blinding was assessed. Results: There were no significant differences between two groups in sex, age, moxibustion experience. In the treatment group and the sham group, the number of subjects who believed they received real moxibustion or sham is not different significantly.(P=.668) The consistency of a moxibustion type which subjects received actually and the their guess about that, isn't different significantly in two groups.(P=.465) Conclusion: The sham moxibustion was successfully validated in this study, The results demonstrate that this sham moxibustion blinds subjects and can be used as effective placebo-control in moxibustion clinical trials.

  • PDF

Use of an Artificial Neural Network to Predict Risk Factors of Nosocomial Infection in Lung Cancer Patients

  • Chen, Jie;Pan, Qin-Shi;Hong, Wan-Dong;Pan, Jingye;Zhang, Wen-Hui;Xu, Gang;Wang, Yu-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5349-5353
    • /
    • 2014
  • Statistical methods to analyze and predict the related risk factors of nosocomial infection in lung cancer patients are various, but the results are inconsistent. A total of 609 patients with lung cancer were enrolled to allow factor comparison using Student's t-test or the Mann-Whitney test or the Chi-square test. Variables that were significantly related to the presence of nosocomial infection were selected as candidates for input into the final ANN model. The area under the receiver operating characteristic (ROC) curve (AUC) was used to evaluate the performance of the artificial neural network (ANN) model and logistic regression (LR) model. The prevalence of nosocomial infection from lung cancer in this entire study population was 20.1% (165/609), nosocomial infections occurring in sputum specimens (85.5%), followed by blood (6.73%), urine (6.0%) and pleural effusions (1.82%). It was shown that long term hospitalization (${\geq}22days$, P= 0.000), poor clinical stage (IIIb and IV stage, P=0.002), older age (${\geq}61days$ old, P=0.023), and use the hormones were linked to nosocomial infection and the ANN model consisted of these four factors. The artificial neural network model with variables consisting of age, clinical stage, time of hospitalization, and use of hormones should be useful for predicting nosocomial infection in lung cancer cases.

Effects of Acupuncture and Moxibustion at SP6(Sanyinjiao) on the Temperature Change of Feet in Healthy Adults (삼음교(三陰交)(SP6) 침구자극(鍼灸刺戟)이 정상 성인의 족부(足部) 온도 변화에 미치는 영향)

  • Kim, June Hyun;Choi, Han Gyul;Park, Min Cheol;Jo, Eun Heui
    • Journal of Acupuncture Research
    • /
    • v.33 no.3
    • /
    • pp.75-87
    • /
    • 2016
  • Objectives : The purpose of this study is to investigate the effects of acupuncture and moxibustion treatment at SP6(Sanyinjiao) on the temperature change of feet in healthy adults and evaluate whether SP6 has an effect on cold hypersensitivity of feet. Methods : Subjects of this study were 61 healthy adults consisting of 21 in the acupuncture treatment group, 21 in the moxibustion treatment group and 19 in the control group, selected at random. After starting the experiment, the subjects laid straight on their back and relaxed for 30 minutes. Pictures were then taken of their feet by DITI 3 times before and after treatment. The treatment was carried out by either 15 minutes of acupuncture or 2 pieces of moxibustion at SP6. Whilst the control group rested lying straight. After taking pictures the temperatures of LR2, GB42, ST42, KI1, center of the plantar, and center of the calcaneus were checked and the SPSS for Windows Version 20.0 was used to evaluate the statistical significance by the paired t-test, Wilcoxon signed-ranks test(in group) and the Mann-Whitney U-test(between the groups). Results : Some temperature changes before and after treatment were observed in each of the 12 areas, most of which were not significant. But as a result of comparing the temperature difference of all the samples without dividing the area of each group, the mean temperatures in the acupuncture and moxibustion group were significantly elevated. A comparison between the groups showed the mean temperature of the acupuncture and moxibustion group to be significantly elevated, more so than the control group. Conclusion : The result of this study suggests acupuncture and moxibustion treatment at SP6 has the effect of the rising temperature of feet temporarily.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Comparison of Right and Left Abdominal Temperature of dysmenorrhea patients using DITI (DITI를 이용한 월경통 여성의 좌우 복부온도 비교)

  • Kim, Seung-Hyun;Ahn, Soo-Jeong;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.2 no.1
    • /
    • pp.24-28
    • /
    • 2003
  • Purpose: We aim to research the difference of abdominal temperature in dysmenorrhea patients comparing with that of normal person. Metholds: We selected the 49 dismenorrhea patients as study group and 54 normal persons as control group, excluding the patients who have dermatitis, ared over 70 or under 10. and have extreme obesity. We compared the 4 points(Rt and Lt Gimun(LR14) and Guirae(ST29)) in thd abdomen of both group, check the temperature of those points with DITI(Dorex, DTI-16UTI) to compare the temperature difference with each other. For statistics, we use independent T-test, SPSS 8.0 for windows. Results: The temperature difference between Rt and Lt Gimun which are in upper abdomen shows statistically significant result in study group. Conclusion: The dysmenorrhea patients show larger temperature difference between Rt and Lt points in upper abdomen than normal persons. In lower abdomen, the temperature between control and study group shows little difference.

  • PDF

Design and Implementation of Interface Module between Network Framework for Sensor Network Application and Co-Simulator (센서네트워크 어플리케이션을 위한 네트워크 프레임워크와 통합시뮬레이터 간의 인터페이스 구현 및 설계)

  • Lee, Jeong-Joo;Koak, Dong-Eun;Seo, Min-Suk;Park, Hyun-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.515-524
    • /
    • 2013
  • For the development of reliable software, Software testing is the most important. Recently small changes of the software according to the importance of regression testing is growing. To verify Application of a large number of nodes, Network simulator environment is required. This paper proposed interface module between network framework for sensor network application and co-simulator to unit test sensor network application. To conclude, developer can focus on sensor network application implementation only, so the improved integrated simulator contributes to increase development productivity.

Comparative Application of Various Machine Learning Techniques for Lithology Predictions (다양한 기계학습 기법의 암상예측 적용성 비교 분석)

  • Jeong, Jina;Park, Eungyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.21-34
    • /
    • 2016
  • In the present study, we applied various machine learning techniques comparatively for prediction of subsurface structures based on multiple secondary information (i.e., well-logging data). The machine learning techniques employed in this study are Naive Bayes classification (NB), artificial neural network (ANN), support vector machine (SVM) and logistic regression classification (LR). As an alternative model, conventional hidden Markov model (HMM) and modified hidden Markov model (mHMM) are used where additional information of transition probability between primary properties is incorporated in the predictions. In the comparisons, 16 boreholes consisted with four different materials are synthesized, which show directional non-stationarity in upward and downward directions. Futhermore, two types of the secondary information that is statistically related to each material are generated. From the comparative analysis with various case studies, the accuracies of the techniques become degenerated with inclusion of additive errors and small amount of the training data. For HMM predictions, the conventional HMM shows the similar accuracies with the models that does not relies on transition probability. However, the mHMM consistently shows the highest prediction accuracy among the test cases, which can be attributed to the consideration of geological nature in the training of the model.

Analysis of Microtoxins in the Nakdong River Watershed

  • Park, Jung-Min;Lee, Jae-Jung;Hwang, Dong-Jin;Yang, Sang-Yong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.99-102
    • /
    • 2003
  • The different methods such as HPLC, indirect- and direct-ELISA were employed for the analysis of microtoxins and the results of each method were compared in terms of the detection limit and accurary. Three toxins, microcystin-RR, -LR and -YR were clearly separated by HPLC using 0.05 M methanol and phosphate buffer used as a solvent system. The calibration curves for the toxins were linear in the range of 5 ng to 50 ng. The standard curves for the immunoassay of microcystin obtained by direct and indirect ELISA are compared. The linear responses of inhibitions of binding by microcystin in the direct and indirect competitive ELISA were in the range of 10 ng to 1000 ng and 50 pg to 160 pg, respectively. Distribution of microtoxins at 11 sites in the Nakdong river and several lakes in Korea was also studied. The most dominant microcystin variant in the test sites was found to be microcystin-RR.

  • PDF

Seismic assessment of base-isolated nuclear power plants

  • Farmanbordar, Babak;Adnan, Azlan Bin;Tahir, Mahmood Md.;Faridmehr, Iman
    • Advances in Computational Design
    • /
    • v.2 no.3
    • /
    • pp.211-223
    • /
    • 2017
  • This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP), high-damping rubber (HDR) and lead-rubber (LR) base isolation. Also, an Excel program was proposed for the design of the abovementioned base isolators in accordance with UBC 97 and the Japan Society of Base Isolation Regulation. The seismic assessment was performed using the pushover and nonlinear time history analysis methods in accordance with the FEMA 356 regulation. To validate the adequacy of the proposed design procedure, two small-scale NPPs were constructed at Universiti Teknologi Malaysia's structural laboratory and subjected to a pushover test for two different base conditions, fixed and HDR-isolated base. The results showed that base-isolated structures achieved adequate seismic performance compared with the fixed-base one, and all three isolators led to a significant reduction in the containment's tension, overturning moment and base shear.