• Title/Summary/Keyword: LPG Flame

Search Result 81, Processing Time 0.027 seconds

Local Concentration and Flame Temperature Characteristics of Combustion Product in Premixed LPG/Air Flames (예혼합 LPG/공기화염에서 연소생성물의 국소농도 및 화염온도특성)

  • 김태권;장준영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2001
  • Measurements of local CO, $CO_2$, $O_2$, $N_2$, $C_3$H$_{8}$, NOx concentrations and flame temperature are made for partially premixed flame with and without acoustic excitation. The CO, $CO_2$, $O_2$, $N_2$, and $C$_3$H_8$ concentrations are determined by thermal conductivity detection (Gas-chromatograph) and NOx concentrations are determined by chemiluminescent detection (NOx analyser). To measure local sample concentration, sampling probe was made by quartz with inlet diameter of 0.25mm. In the case of excitation, the visual shape of the flame is changed from laminar flame to turbulent-like flame. The flame length is also reduced, and the flame width becomes broad. In the observation of emission concentration without acoustic excitation, meanwhile, the $CO_2$ and NOx concentrations peak at flame front where the mixture meets with surrounding air, and the CO concentration is increasing at maximum position of CO2 concentration and peaks at the centerline of the burner. In the case of acoustic excitation, the $CO_2$ concentration is widely occurred at nozzle of the burner and is higher relative to unexcitation. The CO concentration is much reduced, but NOx concentration is more increasing. And flame temperature is higher relative to unexcitation. These are caused by enhancing of mixing with surrounding air due to excitation. However, in the case of acoustic excitation, the total NOx concentration is reduced because of the shortened flame length which affects residence time.e.

  • PDF

Electrical characteristics of soot particles in a LPG diffusion flame and particle size change by electric fields (LPG 확산화염내 매연입자의 전기적 특성 및 전기장에 의한 입자 크기 변화)

  • Park, Jong-In;Ji, Jun-Ho;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1326-1338
    • /
    • 1997
  • Electrical characteristics of soot particles in a LPG diffusion flame were studied for the control of soot particle coagulation. When a DC voltage was applied between two electrodes installed parallel to gas flow, ionic wind effect caused soot deposition on the cathode, implying that most of the soot particles were positively charged. Soot deposit on the cathode linearly increased and was saturated with respect to the strength of the applied voltage. The possibility of applying an AC voltage to enhance the particle coagulation was then investigated and the efficiency of the size control was checked with transmission electron microscope photographs. For the amplitude of 2 kV AC field, primary (spherical) soot particle size decreased from 30 ~ 40 nm to around 20 nm when the frequency of the applied AC voltage was 60 Hz and higher. Collisions between the soot particles in such a selected AC condition could lead to the formation of much bigger agglomerates of roughly 1-5 .mu.m in size.

The Effects of Advanced Reburning with SNCR on NOx and CO Reduction (무촉매 환원법이 적용된 응용 재연소 방법에 의한 NOx와 CO의 저감 효과)

  • Lee Chang-Yeop;Kim Dong-Min;Baek Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.788-795
    • /
    • 2006
  • From the view of the environmental protection against the use of fossil fuels, the great of efforts have been exerted to find an effective method which is not only pollutant reduction but also high thermal efficiency. Reburning is a useful technology in reducing nitric oxide through injection of a secondary hydrocarbon fuel. In this paper, an experimental study has been conducted to evaluate the hybrid effects of reburning and selective non-catalytic reaction (SNCR) on $NO_x/CO$ reduction from oxygen-enriched LPG flame. Experiments were performed in flames stabilized by a co-flow swirl burner, which was mounted at the bottom of the furnace. Tests were conducted using LPG gas as main fuel and also as reburn fuel. The paper reported data on flue gas emissions, temperature distribution in furnace and various heat fluxes at the wall for a wide range of experimental conditions. Overall temperature in the furnace, heat fluxes to the wall and $NO_x$ generation were observed to increase by oxygen-enriched combustion, but due to its hybrid effects of reburning and SNCR, $NOx/CO$ concentration in the downstream has considerably decreased.

Experimental Study on NOx Reduction and CO Emission by Fuel Lean Reburning Process (연료 희박 재연소 과정에 의한 NOx 저감 및 CO 발생에 대한 실험적 연구)

  • Lee, Chang-Yeop;Kim, Hak-Young;Baek, Seung-Wook;Kim, Se-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.216-223
    • /
    • 2008
  • Reburning is a useful technology in reducing nitric oxide through injection of a secondary hydrocarbon fuel. In this paper, an experimental study has been conducted to evaluate the effect of fuel lean reburning on $NO_X/CO$ reduction in LPG flame. Experiments were performed in flames stabilized by a co-flow swirl burner, which was mounted at the bottom of the furnace. Tests were conducted using LPG gas as the reburn fuel as well as the main fuel. The effects of reburn fuel fraction and injection location of the reburn fuel were studied when the fuel lean reburning system was applied. The paper reports data on flue gas emissions and temperature distribution in the furnace for a wide range of experimental conditions. At steady state, temperature distribution and emission formation in the furnace have been measured and compared. This paper makes clear that in order to decrease both NOx and CO concentrations in the exhaust when the fuel lean reburning system was adapted, it is important that the control of some factors such as initial equivalence ratio, reburn fuel fraction and temperature of reburn fuel injection region. Also it shows the fuel lean reburning is also effective method to reduce NOx as much as reburning.

The Development of the Ignition Spark Timing Conversion System for LPG/Gasoline Bi-fuel Vehicle (LPG 및 Gasoline 겸용 차량의 엔진 점화시기 변환 제어시스템 개발)

  • 전봉준;양인권;김재국;김성준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.117-123
    • /
    • 2003
  • In a bi-fuel engine using gasoline and LPG fuel, with the current ignition timing for gasoline being used, the effective performance could not be taken in LPG fuel supply mode. The ignition timing in LPG fuel mode must be advanced much more than that of gasoline mode for the compensation of its lower flame speed, due to engine torque drop. This study aims to develop the control system for ignition spark timing conversion which is composed of hardwares and control algorithm for gasoline/LPG engine. We propose the control system which can advance the ignition spark timing in LPG fuel mode more than used in gasoline fuel mode. The advance of ignition timing is achieved by change of the ignition dwell time of coil igniter. The engine torque and F/E(Fuel-Economy) in LPG fuel mode are measured to evaluate the difference of engine performance between before and alter changing ignition spark timings. The engine torque and F/E are increased respectively, which proves the developed control system is effective so much for gasoline and LPG bi-fuel engine.

A Study on the Transition of Hydrogen-Air and LPG-Air Explosion to Fire (수소와 액화석유 가스의 공기혼합기의 폭발 후 화재로 전이 연구)

  • Oh Kyu-Hyung;Lee Sung-Eun;Rhie Kwang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.150-154
    • /
    • 2004
  • Gas explosion characteristics of hydrogen and liquefied petroleum gas(LPG) were measured in 6L cylindrical vessel, and experiment for explosion to fire transition phenomena of the gases were carried out using the 270L vessel. Explosion characteristics were measured using the stain type pressure transducer and explosion to fire transition phenomena was analyzed with the hish-speed camera. Base on the experiment, it was found that explosion pressure was most high slightly above the stoichiometric concentration, and explosion pressure rise rate and flame propagation velocity were proportional to the combustion velocity. And we find that those kind of explosion characteristics affect the explosion-to-fire transition, in addition, explosion flame temperature, flame residence time, are important parameters in explosion-to-fire transition.

LPG-DME Stratified Charge Compression Ignition Engine (LPG-DME 성층혼합 압축착화 엔진)

  • Bae, Choong-Sik;Yeom, Ki-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.8
    • /
    • pp.672-679
    • /
    • 2007
  • The combustion characteristics of a liquefied petroleum gas-di-methyl ether (LPG-DME) compression ignition engine was investigated under homogeneous charge and stratified charge conditions. LPG was used as the main fuel and injected into the combustion chamber directly. DME was used as an ignition promoter and injected into the intake port. Different LPG injection timings were tested to verify the combustion characteristics of the LPG-DME compression ignition engine. The combustion was divided into three region which are homogeneous charge, stratified charge, and diffusion flame region according to the injection timing of LPG. The hydrocarbon emission of stratified charge combustion was lower than that of homogeneous charge combustion. However, the carbon monoxide and nitrogen oxide emission of stratified charge combustion were slightly higher than those of the homogeneous charge region. The indicated mean effective pressure was reduced at stratified charge region, while it was almost same level as the homogeneous charge combustion region at diffusion combustion region. The start of combustion timing of the stratified charge combustion and diffusion combustion region were advanced compared to the homogeneous charge combustion. It attributed to the higher cetane number and mixture temperature distribution which locally stratified. However, the knock intensity was varied as the homogeneity of charge was increased.