• Title/Summary/Keyword: LOFW

Search Result 2, Processing Time 0.016 seconds

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.

Analysis of Initiating Event Frequencies for PSA Based on the Unexpected Reactor Trip Events in KOREA (국내 원자력발전소 불시정지 이력에 근거한 PSA 초기사건 빈도 분석)

  • 이윤환;정원대
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.177-184
    • /
    • 1999
  • PSA(Probabilistic Safety Assessment) methodology is widely used on assessing the safety of Nuclear Power Plants(NPPs) quantitatively in the domestic nuclear field. Initiating event frequencies are absolutely needed to conduct PSA, and they considerably affect PSA results. There is no domestic database where domestic trip event cases are reflected, so they are used to assess the safety of NPPs that are from the foreign database. In this paper, operating experience data from the Korean NPPs was collected and analyzed for the trip event cases, which are necessary to determine the initiating events and their frequencies. Korean NPPs have experienced five of 16 initiating events, which we LOFW. LOCV, LOCCW, LOOP and GTRN as a result of analyzing the trip event cases. Initiating frequencies based on the domestic trip event cases are analyzed, and they are similar to that from the foreign database.

  • PDF