• 제목/요약/키워드: LINAC radiosurgery

검색결과 43건 처리시간 0.032초

선형가속기를 이용한 뇌수막종의 뇌정위적 방사선수술 (Stereotactic LINAC Radiosurgery of Meningiomas)

  • 류경식;손병철;김문찬;서태석;계철승;윤세철;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권3호
    • /
    • pp.317-323
    • /
    • 2000
  • Objective : To evaluate the role of stereotactic LINAC radiosurgery in treatment of meningiomas, the authors retrospectively analyzed the result of radiosurgery in our institute. Method: During last ten years, twenty patients underwent stereotactic LINAC radiosurgery(LINAC SRS) for meningiomas. The mean age of the patients was 51 years(22-78 years). The most common tumor location for radiosurgery was parasagittal, sphenoid wing and tentorial area. With regards to indications of radiosurgery for meningiomas, LINAC radiosurgery was done for primary treatment in six patients, for postoperative residual tumors in eleven patients, for postoperative regrowth in three patients. Mean tumor volume was $5.14cm^3$($0.28-15.1cm^3$), mean field diameter was 2.01cm(1.2-3cm). The mean marginal dose was 20.55Gy(13-30Gy). The follow-up evaluation was done annually with radiologic findings and clinical status. The mean follow-up period was 46.8(24-120) months. Result : In the radiologic response, the tumor volume was reduced in five(25%) of twenty patients, fourteen showed arrested growth(70%), but one patient showed increased growth(5%). In the clinical response, nine patients improved clinically(45%), ten patients was stable(50%) and one patient worsened during follow-up period. With regards to correlation with radiologic and clinical response, in nineteen patients who showed radiologic response to radiosurgery(decreased and arrested growth after radiosurgery), nine patients(47.4%) improved and ten patients (52.6%) showed no change, one patient(5%) had symptomatic radiation necrosis at four years after SRS, which needed craniotomy. Conclusion : The overall control rate of meningiomas with LINAC radiosurgery was 95% in radiologic follow up and 95% clinically. The radiation complication rate was 5%. These results indicate that LINAC radiosurgery can be considered as safe and effective method for meningiomas.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

LINAC 뇌정의적 방사선 수술시 새로운 최적 선량분포계획 시스템의 개발 (New Techniques for Optimal Treatment Planning for LINAC-based Stereotactic Radiosurgery)

  • 서태석
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.95-100
    • /
    • 1992
  • LINAC 뇌정위적 방사선 수술은 multiple noncoplanar arc, 3 차원 선량 계산 및 많은 조사 변수들이 사용되기 때문에 간단한 경우에도 최적 선량분포를 얻기 위해서는 많은 시간이 요구된다. 본 논문에서는 실험적 방법과 분석적 방법을 통한 유용한 방법을 제시하기 위한 것으로서, 보다 자세한 방법 및 내용은 앞으로의 발표 논문에서 다루게 된다. 실험적 방법으로 2가지 방법에의하면, 첫번째 방법은 multiple isocenter를 이용하는 것이고, 두번째 방법은 beam's eye view와 field shaping을 이용한 conformal therapy이다. 분석적 방법은 최적 조사조건을 찾기 위하여 computer-aided design optimization 방법을 이용하는 것이다.

  • PDF

LINAC을 이용한 뇌정위적 방사선 수술에 대한 3 차원 선량분포 (Three-Dimensional Dose Distribution for the System of Linear Accelerator-based Stereotactic Radiosurgery)

  • Suh, Tae-Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.121-128
    • /
    • 1991
  • 뇌정위적 방사선 수술 시 정확한 3차원적 선량분포에 대한 정보가 필요한다. 3차원적 치료계획은 최적선량분포를 얻기위한 것이며 환자 데이타, 선량분포, 방사선 조사 요소들에 대한 3차원적인 관계를 다루어야만 한다. 원형 조사면에 대한 single 조사면 선량 데이타와 3차원 선량 알고리듬을 이용하여 non-coplanar moving arcs 에 대한 3차원적 선량모델이 개발되었다. 뇌정위적 방사선 수술시 3차원 선량 알고리듬의 적용과 여러경우에 대한 응용에 대하여 논의되어진다.

  • PDF

ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰 (Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator)

  • 문언철;김현진;김영석
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

LINAC 뇌정위적 방사선 수술시 Multiple Isocenters를 이용한 최적 선량분포 계획 (Optimization of Dose Distribution for LINAC-based Radiosurgery with Multiple Isocenters)

  • 서태석;윤세철;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.351-359
    • /
    • 1991
  • LINAC 뇌정위적 방사선 수술은 주로 multiple noncoplanar arc를 이용한 single isocenter를 이용하고 있다. 이러한 방법에 의하면 구형선량 분포를 얻게 되는데, 뇌동정맥 기형이나 뇌종양의 경우 구형이 아닌 임의의 형태를 가진 경우도 많다. 본 논문에서는 임의의 병소형태에 대하여 multiple isocenters를 이용하여 병소모양과 같은 형태의 선량분포를 얻는 방법에 대하여 논하고져 한다. 적당한 조사변수들을 처음에 잘 선정하는 것은, 빠른 시간내에 최적선량 계획을 수행하는데 중요하다. 긴 병소모양에 대하여 같은 형태의 선량분포를 얻기 위한 isocenter 간격 및 조사면에 대한 guideline이 만들어졌다. 특히, 3차원 선량분포를 이용한 multiple isocenters의 응용에 대하여 논하여진다.

  • PDF

선형가속기 방사선 수술을 이용한 뇌동정맥기형의 치료 (Linac Based Radiosurgery for Cerebral Arteriovenous Malformations)

  • 이성열;손은익;김옥배;최태진;김동원;임만빈;김인홍
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권8호
    • /
    • pp.1030-1036
    • /
    • 2000
  • 본 논문에서 뇌동정맥기형에 대해 포톤나이프로 정위적 방사선 수술을 시행한 후 방사선학적으로 10명의 환자중 6례에서 완전 폐색, 4례에서 부분적 폐색을 보였으며, 특히 3cm이하의 작은 뇌동정맥기형 7례중 6례에서 완전 폐색을 보였다(완전 폐색율 : 85.7%). 모든 환자에서 방사선 수술로 인한 방사선학적 합병증의 발병은 없었다. 신경학적으로도 모든 환자에서 방사선 수술 전에 보이던 증상들이 호전을 보였다. 포톤나이프 방사선 수술 시스템은 이미 실험적으로 안정성이 검증된 것으로 이 논문에서 임상적으로 방사선 수술의 안정성 및 정확성을 다시 확인할 수 있었다. 정위적 방사선 수술은 지금까지 치료 불가능했던 부위에 생긴 병소, 수술이나 다른 치료방법으로 완전 제거에 실패한 경우, 노인환자나 다른 내과적 질환으로 수술이 어렵거나 수술적 치료를 거부하는 환자에서도 좋은 치료 방법으로 사용되어지며, 특히 뇌 중요부위나 심부병변에 위치한 경우 또는 최대직경이 3cm 이하의 소 동정맥기형으로 발견 당시 출혈량이 많지 않고 신경학적 결손이 경미한 환자에서 좋은 적응증이 되리라 사료된다.

  • PDF

필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정 (Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • 한국의학물리학회지:의학물리
    • /
    • 제4권2호
    • /
    • pp.9-17
    • /
    • 1993
  • 본 논문의 목적의 NEC LINAC 6 MVX 선의 소조사면에 대한 선량분포를 복잡한 물팬톰 및 ion chamber대신 film 및 고체 물팬톰을 이용하여 간단히 측정하고 분석하는 시스템을 개발하는 데 있다. 단일 선속측정을 위하여 필름과 고체 물팬톰이 이용되었으며, 측정된 데이타는 percent depth dose (PDD), off-axis ratio (OAR) 등을 포함하며, 한변이 1, 2, 3cm의 정사각형 소조사면에 대하여 측정이 이루어 졌다. 또한 Output factor측정은 ion chamber로 측정되었으며, 필름에 의하여 측정된 PDD, OAR 등은 ion chamber측정기로 측정된 값과 비교 검토되었다. 필름으로 부터 측정된 PDD값으로 부터 환산식을 이용하여 tissue maximum ratio (TMR) 값을 얻었으며, 본 실험에서 얻어진 TMR, OAR 값들은 같은 에너지를 나타내는 Philips LINAC의 선량 데이타와 유사한 결과를 보여주었다. 고체 물팬톰 및 필름을 이용한 소조사면 측정은 간편하고도 유용한 방법이었으며, 특히, 자체 개발된 필름팬톰은 뇌정위적 방사선 수술을 위한 OAR 선량을 측정하는 데 유용하였다.

  • PDF

IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발 (Development of 3-D Radiosurgery Planning System Using IBM Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생;박승훈;윤세철
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF