• Title/Summary/Keyword: LIGHT POLLUTION

Search Result 376, Processing Time 0.027 seconds

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.

Estimation of the Light Absorption Contribution for Asian Dust and Polluted Particles at Gosan, Jeju during the Asian Dust Episode in the Spring 2011 (2011년 봄 황사시기 제주도 고산에서의 황사와 오염입자의 광흡수 기여도 산정)

  • Lee, Si-Hye;Kim, Sang-Woo;Yoon, Soon-Chang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.411-422
    • /
    • 2012
  • Ground-based in-situ measurements of aerosol optical properties at Gosan climate observatory have been analyzed to investigate the optical contribution of Asian dust and polluted particles on light absorption in springtime 2011. During the Asian dust episode, the contribution of Asian dust particle to aerosol absorption coefficient estimated about 45% at 370 nm and about 23% at 520 nm. Especially, black carbon in dust plume contributes about 48% to aerosol light absorption at 520 nm since the airmass are transported from the Gobi and inner Mongolia deserts, and this airmass comes across the northeastern coast of China, near the Shandong Peninsula. In pollution case, the contributions of dust particle and black carbon to aerosol absorption coefficient estimated about 41% and 11% at 370 nm, respectively. However, pollution case shows the highest light absorption of 48% for brown carbon at 370 nm, which indicates the significantly high mass concentration of organic carbon ($6.3{\pm}2.2{\mu}g\;m^{-3}$) in pollution plume can contribute to the increase of light absorption at near-UV spectral region.

Evaluatinon of the Surface Water in Southwest Area of Vietnam

  • Thai, Thanh Luom
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.445-452
    • /
    • 2009
  • This study surveys the surface water environment in Southwest sea areas of Vietnam in order to evaluate the current environment. It collects and analyzes experimental results of programs, scientific subjects, and international projects relevant to ecological areas and coastlines of Kien Giang province. The methods analyzed and discussed by specialists are evaluated according to pollution coefficients established by the World Health Organization (WHO), sampling methods, and case study analyses. Comparison between the scale of pollution levels and the surface water quality in experimental areas of Long Xuyen Quadrangle shows a light-moderate pollution level. In Ca Mau Peninsula, the surface water source is only slightly polluted. Sea areas and islands are also light-moderately polluted. Computing results from water quality indices (WQI) show the level of pollution in experimental sites. Activities such as constructing infrastructures for tourism, exploiting minerals, and increasing population accelerate environmental pollution by deteriorating inherently sensitive ecosystems like corals, sea grass, mangrove swamps, and Melaleuca forests. Surveying and evaluating the present situation of surface water are fundamental solutions for environmental protection in the Southwest sea areas of Vietnam.

Characterization of Anti-pollution Film according to the Annealing Temperature for PV Module (태양광 모듈용 내오염성 필름의 열처리 온도에 따른 특성 분석)

  • Yoo, Seung-cheol;Choi, WonSeok;Lim, Yoonsik;Kim, Junghyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.33-36
    • /
    • 2018
  • The purpose of this study is to improve the efficiency of anti-pollution film for PV module. The anti-pollution coating process was performed on a glass substrate, which is the same material as the glass substrate for the PV module. We coated the anti-pollution film on the glass substrate by spray coating. After coating process, annealing process was performed during 1 hour at $200^{\circ}C$, $300^{\circ}C$, and $400^{\circ}C$. And then we analyzed the surface characteristics according to the annealing temperature of the film. Annealing process can also improve the durability of the coated film. And then we analyzed the anti-pollution characteristics, particle size of anti-pollution film, light transmittance. The particle size of anti-pollution film was analyzed with FE-SEM. The light transmittance was analyzed with UV-Visible spectroscopy including integrating sphere.

Absorption properties and size distribution of aerosol particles during the fall season at an urban site of Gwangju, Korea

  • Park, Seungshik;Yu, Geun-Hye
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.159-172
    • /
    • 2019
  • To investigate the influence of pollution events on the chemical composition and formation processes of aerosol particles, 24-h integrated size-segregated particulate matter (PM) was collected during the fall season at an urban site of Gwangju, Korea and was used to determine the concentrations of mass, water-soluble organic carbon (WSOC) and ionic species. Furthermore, black carbon (BC) concentrations were observed with an aethalometer. The entire sampling period was classified into four periods, i.e., typical, pollution event I, pollution event II, and an Asian dust event. Stable meteorological conditions (e.g., low wind speed, high surface pressure, and high relative humidity) observed during the two pollution events led to accumulation of aerosol particles and increased formation of secondary organic and inorganic aerosol species, thus causing $PM_{2.5}$ increase. Furthermore, these stable conditions resulted in the predominant condensation or droplet mode size distributions of PM, WSOC, $NO_3{^-}$, and $SO{_4}^{2-}$. However, difference in the accumulation mode size distributions of secondary water-soluble species between pollution events I and II could be attributed to the difference in transport pathways of air masses from high-pollution regions and the formation processes for the secondary chemical species. The average absorption ${\AA}ngstr{\ddot{o}}m$ exponent ($AAE_{370-950}$) for 370-950 nm wavelengths > 1.0 indicates that the BC particles from traffic emissions were likely mixed with light absorbing brown carbon (BrC) from biomass burning (BB) emissions. It was found that light absorption by BrC in the near UV range was affected by both secondary organic aerosol and BB emissions. Overall, the pollution events observed during fall at the study site can be due to the synergy of unfavorable meteorological conditions, enhanced secondary formation, local emissions, and long-range transportation of air masses from upwind polluted areas.

Environmental Pollution of Ondal Cave

  • Sin, Dae-Bong
    • Journal of the Speleological Society of Korea
    • /
    • no.85
    • /
    • pp.15-17
    • /
    • 2008
  • This paper is attempted to review a cave restoration and preservation plan against environmental destruction and pollution as a preliminary survey for preservation of cave environment. Consequently, it's important to throw an indirect light rather than direct light on cave formations, keeping distance of 2m at least. The already existing moss should be removed using wet cloth or sponge as soon as possible. If it's washed off, be careful not to splash it or water on nearby subjects. Based on an automatic switch-off system, light will automatically turn off when no one is left in the cave. It's also recommended to dualize the cave passage and partially close the cave by taking turns to give a time to recover.

A Study on the Luminance Measuring Method and Regional Measured Results for Outdoor Signboards with Lighting Considering Light Pollution (빛공해를 고려한 옥외발광광고물의 휘도측정법 연구 및 지역별 측정결과)

  • Kim, Hyun-Ji;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.1-8
    • /
    • 2012
  • To suggest lighting regulations to prevent light pollution, domestic and international standards were analyzed and the luminance of outdoor signboards of main street at night was measured. In addition, to regulate the methods of luminance measurement, experiments on the measuring distance and direction from the signboards were conducted. The regulations were set as maximum luminance for outdoor signboard lightings of channel letter type, and limitations were suggested on each of the four lighting zones.

A Study on the Emission Characteristics of Korean Light-duty Vehicles in Real-road Driving Conditions (국내 소형자동차의 실제 도로 주행 배출가스 특성에 관한 연구)

  • Park, Junhong;Lee, Jongtae;Kim, Sunmoon;Kim, Jeongsoo;Ahn, Keunwhan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.123-134
    • /
    • 2013
  • Strengthening vehicle emission regulation is one of important policies to improve air quality in urban area. Due to the limitation of specified driving cycles for certification test to reflect real driving conditions, additional off-cycle emission regulations have been adopted in US and being developed in Europe. The driving cycles of US or Europe have been used in emission certification for Korean light-duty vehicles, but it has not been known how well the driving cycles reflect various real driving patterns in Korea. In that point of view, it is required to estimate vehicle emission based on real road driving conditions to raise the effectiveness of vehicle emission regulation in Korea. In this study, real driving emission measurements have been conducted for three Korean light-duty vehicles with PEMS. The driving routes consisted of urban, rural and motorway in Seoul and Incheon. The data have been analyzed with various averaging methods including moving averaging windows method and compared to emission limits set with emission certification modes applied to tested vehicles. The results have shown that the real driving pollutant emissions of a gasoline and a LPG vehicles have been ranged quite lower than those of emission limits on CVS-75 driving cycle. But real driving NOx of a light duty diesel vehicle has been considerably higher than emission limit of NEDC driving cycle. The higher than expected NOx emission of a diesel vehicle might be caused by different strategy to control EGR in real driving condition from NEDC driving.

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.

Study on a Forward Light Changes According to the Surface Treatment of Light Cutoff Panel (차광판 표면 처리 방법에 따른 전사광 변화에 관한 연구)

  • Gu, Jinhoi;Kwon, Myunghee;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.1-5
    • /
    • 2014
  • Since the "Light Pollution Prevention Act" was executed, the installation of the light cutoff panel to the security lightings which caused light trespass has been increased in the local government. The light cutoff panel is effective in reducing the light trespass in term of the cost-benefit. Because the installation of the light cutoff panel is inexpensive than the change of the security lighting. But the reflected light from the surface of the light cutoff panel has been regarded as another light pollution problem to solve. Therefore, we try to improve light cutoff panel by changing the light reflectivity characteristic of the surface of the light cutoff panel. First, we laminated the surface of light cutoff panel by black powder to reduce the light reflectivity of the light cutoff panel. After the black powder lamination, the light reflectivity on the light cutoff panel improved from 85% to 5%. And we compared reflected light caused by black powder laminated light cutoff panel with the one of no surface treatment cutoff panel. The vertical illuminance was measured at 3, 6, 9m in front of the security lighting and 3, 6, 9, 12, 15, 18m in back of the security lighting to evaluate the reflected light. And the measurement height was determined of 1.5m considering the height of the 1th floor of an apartment house. In this study, we found that the reflected light from the light cutoff panel can be reduced about 90% by the black powder lamination method. The results derived from this study will be helpful to develope the various kind of light cutoff panel which minimize the adverse effect like reflected light of light cutoff panel.