• Title/Summary/Keyword: LHe

Search Result 68, Processing Time 0.025 seconds

Temperature Characteristic of Rotor of HTS Synchronous Machine cooled by Solid Nitrogen (고체질소 냉각 고온초전토 동기기용 회전자의 온도특성)

  • Jo, Young-Sik;Hong, Jung-Pyo;Lee, Ju;Sim, Ki-Deck;Sohn, Myoung-Hwan;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.95-97
    • /
    • 2001
  • This paper deals with cryogen, which is used solid nitrogen to keep the operating temperature of High Temperature Superconducting (HTS) synchronous machine. To make the solid nitrogen of liquid nitrogen, liquid helium (LHe) passes into and cools the heat exchanger to its own temperature. Two types of heat exchangers are designed and manufactured to make the solid nitrogen, and temperature characteristics of those compare with each other. The rotor cooled by latent heat of solid nitrogen and it is kept under 40K during 2 hours and 30 minutes without LHe.

  • PDF

Performance Characteristics of Plate Heat Exchangers with Various Geometric Design Parameters (기구적 설계변수에 따른 판형열교환기의 성능특성)

  • Son, Jae-Wook;Lee, Eung-Chan;Kang, Hoon;Kim, Yong-Chan;Kim, Jung-Kyu;Cho, Sung-Youl;Park, Jae-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.583-591
    • /
    • 2012
  • Plate heat exchangers have been widely used in many industrial applications because of their compactness and high efficiency. Even though plate heat exchangers have been investigated extensively, studies on the effects of geometric parameters other than the chevron angle are very limited in the open literature. In this study, the effects of the chevron angle, corrugation length, corrugation depth, and the number of plates on the heat transfer and pressure drop characteristics of plate heat exchangers were investigated experimentally. Based on the experimental results, empirical correlations were proposed. More than 95% of the predictions made based on the correlations had relative deviations of less than ${\pm}10%$ when compared with the measured data.

A Study on the Utilization of Waste Tire/Waste Moter Oil Pyrolytic Residue for Asphalt (폐타이어/폐윤활유 열분해 잔류물의 아스팔트 활용기술)

  • 김상국;손성근;김동찬
    • Resources Recycling
    • /
    • v.4 no.4
    • /
    • pp.16-21
    • /
    • 1995
  • When waste t~re/~vastmz otor oil is pyrolyzed. most of them hecome gaseous produds. and thc remaining onc, whascwelght is ahout in% oi the waste Ore, is pyrolyced residue mnstly composcd oi ca~bnn black A rescsrcll was canicrl nut loutilize lhe pyralyred residue of waste tnelwuste lnotol 011 us retnin~cing agent of asphall concrete, bescd on iolelg~r lesearchrepurl. This shows thal the properlies ol asphall concrele ~nclud~cd~ugl ah~l~tyre, sistance to Tear. temperature-v~scusilysusceptil,ilily u e g reatly improved when lhe pellellrcd hrln aI carlmn hlack usmg petroleum o ~als a hinder Iar ihe pellels isused with asphalt. The surface of the pyralyred resirh~ei s covned by ocl film and thla lnakes good comllatibllity with asphallIn order lo ulilk pyrolyzed residue as a reinforcing agenl oi lhe itsphalt concrete, various tests such as Marshnll tcsi, wheeltracking, and revelhng test has been carried out a1 KLER, Ko~ea I-lighway Coo~poration, and TCMO. Tcst lcsults satirry KSslandard, show "npmvements an the dynam~cs tab~l~lzym, d incrcase reslslance to wear at cold telnpelatule Invrsligadon wascarlied oul to sludg the possibility of soil pallul~on when pyrolyzed residue is used as a tzmioicing agenl. E~pcrimentalresulls show the rcsidue contained in thc asphall docs not cause cnv~ranma~lparlo blems.e cnv~ranma~lparlo blems.

  • PDF

A Retrospective Study of Radiographic Measurements of Small Breed Dogs with Myxomatous Mitral Valve Degeneration: A New Modified Vertebral Left Atrial Size

  • Soyon An;Gunha Hwang;Seul Ah Noh;Young-Min Yoon;Hee Chun Lee;Tae Sung Hwang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.31-37
    • /
    • 2023
  • Vertebral left atrial size (VLAS) is an important indicator to predict myxomatous mitral valve degeneration (MMVD) in dogs. When the caudal margin of cardiac silhouette and the dorsal margin of caudal vena cava (CdVC) could not be seen exactly, another way to evaluate VLAS is needed. The objective of this study was to assess whether a new modified VLAS (m-VLAS) could be used as an indicator to predict MMVD in 57 small breed dogs with MMVD. The m-VLAS was also used to classify American College of Veterinary Internal Medicine staging groups and left heart enlargement confirmed with echocardiograph (EchoLHE) groups. The m-VLAS was measured as the distance from the ventral aspect of the carina to the dorsal aspect of the intersection of the cardiac silhouette and the farthest LA caudal margin, not the CdVC, followed by drawing the same line beginning at the cranial edge of T4. Based on VLAS values and m-VLAS values measured for dogs with MMVD, correlations between these values and left heart enlargement groups were then evaluated. There were significant differences in both the VLAS and the m-VLAS between EchoLHE groups. The AUC of the ROC curve of the m-VLAS to detect EchoLHE was higher than that of the VLAS. The optimal cutoff value for the m-VLAS was >2.7, which had a higher specificity (86.84%) than the VLAS specificity (71.05%). This study reveals that a new m-VLAS is a more specific indicator than the VLAS for predicting left side heart enlargement in small breed dogs. Therefore, the m-VLAS can be used as a clinically useful radiographic measurement alternative to or better than the VLAS.

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Development and Validation of Cryopanel Cooling System Using Liquid Helium for a Satellite Test (액체헬륨을 이용한 위성시험용 극저온패널 냉각시스템 개발 및 검증)

  • Cho, Hyok-Jin;Moon, Guee-Won;Seo, Hee-Jun;Lee, Sang-Hoon;Hong, Seok-Jong;Choi, Seok-Weon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.213-218
    • /
    • 2010
  • A cooling system utilizing liquid helium to chill the cryopanel (800 mm $\times$ 700 mm dimensions) down to 4.2 K was designed, implemented, and tested to verify the role of the cryopanel as a heat sink for the payload of a spacecraft inside the large thermal vacuum chamber (effective dimensions : 8 m ($\Phi$) $\times$ 10 m (L)) of KARI (Korea Aerospace Research Institute). Two LHe (Liquid Helium) Dewars, one for the main supply and the other for refilling, were used to supply liquid helium or cold helium gas into this cryopanel, and flow control for the target temperature of the cryopanel within requirements was done through fine adjustment of the pressure inside the LHe Dewars. The return helium gas from the cryopanel was reused as a thermal barrier to minimize the heat influx on the core liquid helium supply pipe. The test verified a cooling time of around three hours from the ambient temperature to 40 K (combined standard uncertainty of 194 mK), the capacity for maintaining the cryopanel at intermediate temperatures, and a 1 K uniformity over the entire cryopanel surface at around 40 K with 20 W cooling power.

A study of psychiatric patients perceived effect and expectance of the activity therapy (정신과 환자가 인지한 활동요법의 효과와 기대에 대한 연구)

  • Kim, Soyasa;Kim, Hyunsook;Yoon, Soojean;Jung, Hyangln;Sung, Kyungmi
    • The Korean Nurse
    • /
    • v.31 no.4
    • /
    • pp.62-76
    • /
    • 1992
  • The intent of chis descriptive study is to investigale lhe patients perceived effect and expectance of activity therapy. The subjects for this study were 56 patients from the psychiatric ward in Severance Hospital. The data were collected during Lhe period from June 1, 1991 to January 18, 1992. The effect and expectance of the activity therapy was measured using a questionnaire developed by this study's investigators. The date were analyzed by descriptive statistics, t-test ancl one-way ANOVA, using the SPSS program. The results of this study can ue summarized as following ; 1. For motivatiorc for the accivity therapy, the response range was from 64.;] % to 89.3 %, that is, it showed a relatively positive response. 2. For the degree of improvement according to the nurse's method in the activity therapy, it was shown that the nurses need professional skill and meeting after activity therapy. 3. For the relevance of the nurse in the activity therapy, 90 % of the subjects had a positive answer for all of the activity therapy except the painting therapy. 4. For the perceived effect of the activity therapy, the following results were obtained. 1) 92% of the subjects had a positive response to the dance therapy, that is-I am vigorous physically. 2) 90 % of the subjects had a positive response to the reading therapy, that is-I acquire good ideas and instruction. 3) 98.1 % of the subjects had a positive response to the recreation therapy, that is-I am joyful. 4) 88.9% of the subjects had a posilive response to the writing therapy, that is-I am interested and become acquainted with other patients. 5) 86.8 % of tbe subjects had a positive response to the occupation therapy, that is-I am happy when I work. 6) 92.6 % of the subjeccs had a positive response to lhe painting therapy, that is-I can express myself in painting. 7) 87.3% of the subjects had a positive response to the musie therapy, that is-I am comforted. 5. For the expectance related to the activity therapy, 97.1 % the subjects had the most postive response to the music therapy which is a pleasant comfortable time. From the above-mentioned findings, it is suggested that psychiatric nurses need to development systematic and professional group activity therapy, and know the patient premorbid hobbies, interests and occupations.

  • PDF

An experimental study on performance evaluation for development of compact steam unit applied with hybrid plate heat exchanger (하이브리드 판형 열교환기 적용 컴팩트 스팀 유닛 개발을 위한 성능 평가에 관한 실험적 연구)

  • Park, Jae-Hong;Cho, Sung-Youl;Lee, Jun-Seok;Lee, Sang-Rae;Kim, Seung-Hyun;Lim, Gye-Hun;Seo, Jung-Wan;Kim, Jeung-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.296-301
    • /
    • 2017
  • In various industrial places such as power generation plants, petrochemical and unit factories, the demands of systems that produce hot water by utilizing wasted or surplus steam have been increased. Compact steam unit(CSU) is a system that can meet these demands and produce hot water by using surplus or wasted steam, and it is also one of the good solutions in view of energy reuse. The new CSU with a capacity of 1,600 kW was developed with a hybrid plate heat exchanger of which thermal performances are better than a conventional plate heat exchanger, an improved temperature control valve, a user-friendly control system, and other components in this study. The purpose of this study was to obtain performance data of the new CSU through various experiments and utilize them for the CSU commercialization. The experimental results show that heat balances between the hot side(steam) and the cold side(cold water) were within ${\pm}0.77%$, and the fluctuations of outlet temperature of the secondary side which are one of the most important evaluation factors in the CSU were $(0{\sim}0.3)^{\circ}C$.

A basic study on development of high-pressure compact steam unit applied hybrid heat exchanger (하이브리드 열교환기 적용 고압 컴팩트 스팀 유닛 개발에 관한 기초 연구)

  • Kim, Jeung-Hoon;Lim, Gye-Hun;Kim, Seung-Hyun;Jin, Chul-Kyu;Park, Jae-Hong;Cho, Sung-Youl;Hong, In-Ki;Lee, Sang-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.453-457
    • /
    • 2016
  • In various industrial plants such as power generation plants, petrochemical plants, and unit factories, there is an increasing demand for a system that generates hot water using waste or surplus steam. Compact steam unit (CSU), which produces hot water by using steam, is a good solution considering energy reuse. In this study, as a basic study to develop a high-pressure CSU, heat transfer characteristics of a hybrid heat exchanger were investigated through experiments, in order to use the hybrid heat exchanger instead of a conventional plate heat exchanger as the core component of CSU. The experimental results are the followings. Heat balance between the hot side and cold side was satisfied within ${\pm}5%$. Overall heat transfer coefficient increased linearly as the Reynolds number increased and exceeded $5,524W/m^2K$ when the flow velocity was above 0.5 m/s. In addition, pressure drop also increased as the Reynolds number increased, and pressure drop per unit length was below 50 kPa/m.