• Title/Summary/Keyword: LF(Low Frequency)

Search Result 164, Processing Time 0.025 seconds

Effects of High Frequency Repetitive Transcranial Magnetic Stimulation on Function in Subacute Stroke Patients

  • Cha, Hyun-Gyu;Kim, Myoung-Kwon;Nam, Hyoung-Chun;Ji, Sang-Goo
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.192-196
    • /
    • 2014
  • The aim of the present study was to examine the effects of high and low frequency repetitive transcranial magnetic stimulation on motor cortical excitability and the balance function in subacute stroke patients. Twenty-four subjects were randomly assigned to either the high frequency (HF) rTMS group, or the low frequency (LF) rTMS group, with 12 subjects each. All subjects received routine physical therapy. In addition, both groups performed a total of 20 sessions of rTMS for 20 minutes, once a day, 5 times per week, for a 4-week period. In the HF rTMS group, 10 Hz rTMS was applied daily to the hotspot of the lesional hemisphere; and in the LF rTMS group, 1 Hz rTMS was applied daily to the hotspot of the nonlesional hemisphere. Motor cortex excitability was determined by motor evoked potentials, and the balance function was evaluated by use of the Balance Index (BI) and the Berg Balance Scale (BBS), before and after the intervention. The change rate in the value of each variable differed significantly between the two groups (p<0.05). Furthermore, significant differences were observed between all post-test variables of the two groups (p<0.05). In the HF rTMS, significant differences were found in all the pre- and post-test variables (p<0.05). On the other hand, in the LF rTMS, significant difference was observed only between the pre- and post-test results of BI and BBS (p<0.05). The findings demonstrate that HF rTMS can be more helpful in improving the motor cortical excitability and balance function of patients with subacute stroke treatment than LF rTMS, and that it may be used as a practical adjunct to routine rehabilitation.

Effect of solenoid valves on the response characteristics of a hydraulic position-control system (솔레노이드 밸브가 유압위치제어 시스템의 응답특성에 미치는 영향)

  • 장효환;안병홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.364-369
    • /
    • 1987
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinued control methods i.e., Simple On-Off (SOF) and Pusating On-Off(POF) controls. Three types of solenoid valves i.e. low-frequency, closed-center type (LF/C), high-frequency, closed-center type (HF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

  • PDF

Characteristics of Low-frequency Ambient Seismic Noise in South Korea (국내 저주파수 무작위 지진잡음의 특성 연구)

  • Park, Iseul;Kim, Ki Young;Byu, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.67-75
    • /
    • 2016
  • To investigate spatial and temporal variations of low-frequency (${\leq}5Hz$) ambient seismic noise, we analyzed the noise data recorded for one whole year of 2014 at surface accelerometer stations in South Korea. After decomposed into low-frequency (LF; < 1 Hz) and high-frequency (HF; ${\geq}1Hz$) components, the root-mean-squared (RMS) amplitudes and power spectral densities (PSD) of the noise data were computed. The RMS amplitudes were larger on islands and near-shore stations, but also large RMS amplitudes were observed at inland stations in large cities only for HF components. The RMS amplitudes of HF components were larger in the daytime than at nighttime and during weekdays than on Sunday and holidays. This indicates the HF components are closely related to human activities. On the contrary, daily and weekly variations were not clear in the LF components while they showed seasonal variations with its maximum during the winter and a good correlation with significant wave height. Therefore, we interpret the mechanism of LF components is closely related to natural phenomena such as sea. The amplitude of LF components decreased as an exponential function of the distance to the center of typhoons. The exponential index of -0.76 suggested that ambient seismic noise included both surface and body waves. Peak frequencies of the PSD curves were near 0.34 Hz indicating the double frequency. No temporal variation in the peak frequency was clearly noticed.

Autonomic Nervous Response of Female College Students with Type D Personality during an Acute Stress Task: Heart Rate Variability (Type D 성격 여대생의 급성 스트레스에 따른 자율신경계 반응 : 심박률 변동성을 중심으로)

  • Ko, Seon-Young;Kim, Myung-Sun
    • Korean Journal of Health Psychology
    • /
    • v.14 no.2
    • /
    • pp.277-292
    • /
    • 2009
  • This study investigated the responses of the autonomic nervous system of individuals with Type D personality during an acute stressful situation. Twenty-three female students of Type D personality and 23 female students with non-Type D personality. Stroop Color-Word Task was used to induce a stressful situation, heart rate variability (HRV) was used to measure the responses of the autonomic nervous system during the baseline, acute stress, recovery periods. To analyze the data, the repeated measures analysis of variance was used to compare the autonomic nervous system of the Type D group to that of the non-Type D group. Regression analysis is used to determine if the Type D scale and stress vulnerability predicted the activities of the autonomic nervous system during the baseline period. The results of this study demonstrated that the Type D group's normalized low frequency (LF norm) and ratio of low frequency to high frequency (LF/HF ratio) were higher than those for the non-Type D group, while its normalized high frequency (HF norm) was lower than that for the non-Type D group in all three periods. There were no statistically significant differences among the three periods in terms of LF norm, HF norm, and LF/HF ratio in the Type D group. The study demonstrated that the total scores of the Type DS-14 and scores of social inhibition and negative affect were independent predictors of LF norm and HF norm during the baseline. The Type D group showed increased activation of the sympathetic nervous system and/or decreased activation of the parasympathetic nervous system. These results support the hypothesis that the Type D personality is vulnerable to the stress. Also, the highly activated sympathetic and/or lowly activated parasympathetic nervous systems, which were observed in the Type D group during the baseline, indicated that the Type D individual is susceptible to psychosomatic disorders.

Optimal Control of Dynamic Positioned Vessel Using Kalman Filtering Techniques (칼만필터를 이용한 부유체운동의 최적제어)

  • Lee, Pan-Muk;Lee, Sang-Mu;Hong, Sa-Yeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.37-45
    • /
    • 1988
  • A dynamically positioned vessel must be capable of maintaining a specified position and direction by controlling the thruster devices. The motions of a vessel are often assuned to tne sum of low frequency(LF)motions and high frequency(HF)motions. The former is mainly due to wind, current and second order wave forces, while the latter is mainly due to first order wave forces. In order to avoid the high frequency thruser modulation, the control system must include filters to estimate the low frequency motions from the measured motion signals, This paper presents a control system based on Kalman filtering technique and optimal control tyeory. Using the combined kalmam filter, LF motion estimates and HF ones are achieved from the motion measurement of the vessel. The estimated low frequency motions are used as inputs to the dynamic positioning system. The thruster modulation is minimized using the optimal control theory; Linear Quadratic Gaussian(LQG)controller. The performances of the Kalman filter and the dynamic positioned vessel are investigated by computer simulation.

  • PDF

A Study of the Characteristics of the HRV of the Girl Showing a Precocious Puberty (성조숙 증상을 보이는 여아들의 HRV의 특성 연구)

  • Yang, Seung-Jeong;Park, Kyung-Mi;Cho, Seong-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.10-22
    • /
    • 2016
  • Objectives: The aim of the study was to investigate the characteristics of the autonomic innervation of the heart in Precocious Puberty (PP) Girls.Methods: We studied 87 girls visiting Dongshin University Suncheon Oriental Medicine hospital from first Januarty 2013 to 31th December 2015. Among the 87 girls who were selected 14 people under the age of 8. The subjects were categorized in two groups, 2 PP girls and 12 healthy controls. We studied the difference of Heart rate variability (HRV) between two groups by Independent samples T-test using SPSS for windows (version 22.0).Results: The Standard deviation of all normal R-R intervals (SDNN), The spuare root of the sum of the spuare of difference between adjacent normal R-R intervals (RMS-SD) of PP group was non-significantly lower than non-PP group. Total power (TP), Very low frequency power (VLF), High frequency power (HF), Low frequency power (LF) of PP group was non-significantly lower than non-PP group, LF/HF ratio of PP group was significantly higher than non-PP group. Normalized high frequency power (HF norm) of PP group was non-significantly lower than non-PP group. Normalized low frequency power (LF norm) of PP was non-signficantly higher than non-PP group.Conclusion: The results suggest that imbalance of sympathetic and parasympathetic nervous system from girls of precocious puberty can be seen.

A Study on Oriental Medicine Diagnostic Application through Analysis of Heart Rate Variability in Polycystic Ovary Syndrome Females (PCOS 여성의 HRV 특성 분석을 통한 한의학적 진단 활용성에 관한 연구)

  • Lee, Mi-Joo;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Khung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.4
    • /
    • pp.155-163
    • /
    • 2010
  • Purpose: The aim of the study was to compare the characteristics of the autonomic innervation of the heart in polycystic ovary syndrome(PCOS) patients with regulary cycling controls. Methods: We studied 21 patients visiting $\bigcirc\bigcirc$hospital from 25th June 2009 to 25th June 2010. The subjects were categorized in two groups, 11 PCOS patients and 10 healthy regularly cycling controls. We studied the difference of Heart rate variability (HRV) between two groups by Independent samples T-test using SPSS for windows(version 17.0). Results: The Standard deviation of all normal R-R intervals (SDNN), The spuare root of the sum of the spuare of difference between adjacent normal R-R intervals (RMS-SD) of PCOS group was non-significantly lower than non-PCOS group. High frequency power (HF) and Normalized high frequency power (HF norm) of PCOS group was significantly higher than non-PCOS group. Normalized low frequency power (LF norm) of PCOS was signficantly lower than non-PCOS group. The results means increased sympathetic and decreased vagal modulation. Total power (TP), Very low frequency power (VLF) of PCOS group was non-significantly lower than non-PCOS group. Low frequency power (LF), LF/HF ratio of PCOS group was non-significantly higher than non-PCOS group. Conclusion: The results suggest that PCOS can be related to decreased activity of parasympathetic nervous system.

Obstructive Sleep Apnea Analysis Based on Heart Rate Variability (폐쇄성 수면 무호흡 검출을 위한 심박동변이율 분석)

  • Ye, Soo-Young;Kim, Jung-Guk;Kim, Dong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.605-608
    • /
    • 2011
  • In this study, OSA (the obstructive sleep apnea) periods were detected in patients with OSA during sleep because of the treatment was different according to the frequency and symptoms of obstructive sleep apnea. ANS (autonomic nervous activity) was changed by obstructive sleep apnea periods so we intended to detect the periods to care the obstructive sleep apnea patients. RR intervals, SDNN (standard deviation of normal to normal) and RMSSD (root mean square standard deviation) were calculated in time domain analysis and LF (low frequency), HF (high frequency), NHF (normalized high frequency), NLF (normalized low frequency) were calculated in frequency domain analysis of HRV (heart rate variability) with obstructive sleep apnea patients. In this paper, SDNN (standard deviation of normal to normal) of time domain analysis were decreased in the obstructive sleep apnea periods. And NLF and LF/HF ratio were increased and NHF (normalized high frequency) was decreased in the frequency domain analysis. The parameters can be used to treat obstructive sleep apnea patients by detecting the obstructive sleep apnea periods such as CPAP (continuous positive airway pressure).

No Spike PFD(Phase Frequency Detector) Using PLL( Phase Locked Loop ) (PLL(phase locked loop)을 이용한 No Spike 위상/주파수 검출기의 설계)

  • 최윤영;김영민
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1129-1132
    • /
    • 2003
  • 본 논문에서는 위상/주파수 검출기을 설계시 문제가 되는 Reference Spur을 없게 하여 Low Noise를 구현할 수 있는 No Spike PFD(Phase Frequency Detector)를 제안한다. 위상동기루프의 특별한 형태로 차지 펌프 위상동기루프가 있다. 차지 펌프위상동기 루프는 일반적으로 3-state 위상/주파수 검출기를 이용한다. 이 3-state 위상/주파수 검출기는 기준 신호와 VCO 출력 신호의 위상차에 비례하는 디지털 파형으로 출력을 내보낸다. 차지 펌프 위상동기루프 그림 1 처럼 디지털 위상/주파수 검출기(PFD), 차지 펌프(CP), 루프 필터(LF), VCO로 구성된다. PFD 는 기준 신호와 VCO 에 의해 만들어진 출력 신호를 입력받아 각각의 위상과 주파수를 비교한다. 즉, 출력 신호가 기준 신호보다 느릴 때에는 출력 신호를 앞으로 당기기 위해서 up 신호를 넘겨주고, 출력 신호가 기준 신호보다 빠를 때에는 출력 신호를 뒤로 밀기 위해 down 신호를 넘겨준다. 차지 펌프(CP)의 전류를 Ip 라고 한다면, CP 에서 LF 로 흐르거나, LF에서 CP로 흐르는 전류 Ip의 평균량이 기준 신호와 VCO 출력 신호의 위상차에 비례하는 것이다.

  • PDF

High Frequency Link PCS for Interfacing with Power Utility System (고주파링크 전력계통 연계형 PCS)

  • Chung, Bong-Gun;Yoon, Kwang-Ho;Lee, Kwang-Ho;Kim, Eun-Soo;Cha, In-Su
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • Recently, Power Conditioning System (PCS) tends to require more compact, higher efficiency and power density with better performance. A novel topology consisted of LLC resonant inverter and Low Frequency (LF) cyclo-converter for connecting to utility line is able to meet these requirements. The technical operating analysis is described and 1kW prototype is tested and verified the performances through connecting the 110Vac 60Hz utility line. Efficient results are described.