• Title/Summary/Keyword: LF(Low Frequency)

Search Result 164, Processing Time 0.024 seconds

Effect of Transient Isokinetic Exercise on Cardiac Autonomic Nervous Modulation and Muscle Properties (일회성 등속성 운동이 심장 자율신경 조절 및 근속성에 미치는 영향)

  • Soo-Kyoung Park;Si-Eun Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.4
    • /
    • pp.27-39
    • /
    • 2023
  • Purpose : The aim of this study was to identify the influence of transient isokinetic exercise on cardiac autonomic modulation and muscle properties in healthy male subjects. Methods : Twenty-eight healthy males underwent isokinetic exercise of both knee joints using a Biodex systems 3 isokinetic dynamometer with an angular velocity of 60 °/sec. The changes in activity of the autonomic nervous system, as determined by heart rate variability (HRV), and in muscle properties were evaluated at three times: pre-exercise, immediately post-exercise, and 10 min post-exercise. Results : The time domain analysis of HRV revealed significant changes in the beat count and mean and minimal heart rate (HR) measured at pre-exercise, immediately post-exercise, and 10 min post-exercise (p<.001). The beat count and mean HR were markedly increased immediately post-exercise compared to pre-exercise, but then significantly decreased at 10 min post-exercise (p<.001). All parameters of the frequency domain were significantly altered by isokinetic exercise (p<.01). The low frequency/high frequency (LF/HF) ratio, as an index for the sympathovagal balance, was elevated by exercise and remained at a similarly high level at 10 min post-exercise (p<.01). The muscle properties of rectus femoris were changed as follows: Muscle tone and stiffness were significantly increased between pre-exercise and immediately post-exercise (p<.001), and between pre-exercise and at 10 min post-exercise (p<.001). Whereas, the elasticity showed no significant change. Conclusion : These results demonstrated that transient isokinetic exercise could induce changes in cardiac autonomic control and muscle properties. In particular, up-regulation of LF/HF ratio after exercise signifies thus enhanced sympathetic modulation by isokinetic exercise. Therefore, it is needed to understand the cardiovascular risks that may arise during isokinetic exercise for providing the basic evidence to establish appropriate isokinetic exercise protocols as effective rehabilitation exercises.

Effects of Frequency-Dependent Neuromuscular Electrical Stimulation on The Respiratory Strength, Quadriceps Muscle Activity and Quality of Life in Patients with Severe Chronic Obstructive Pulmonary Disease (주파수에 따른 신경근전기자극치료가 중증 만성폐쇄성폐질환 환자의 호흡근력, 넙다리네갈래근 활성도 및 삶의 질에 미치는 영향)

  • Kang, Jeong-Il;Jeong, Dae-Keun;Park, Jun-Su
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.81-89
    • /
    • 2019
  • PURPOSE: To solve the problems of chronic obstructive pulmonary disease (COPD) patients complaining of muscle fatigue and having limited motor abilities, this study provided the clinical basic data for pulmonary rehabilitation by examining the effects of High Low-Frequency Neuromuscular Electrical Stimulation (NMES) on the respiratory muscle strength, quadriceps muscle activity, and life quality. METHODS: Samples were collected from 20 COPD patients and placed randomly in a low-frequency group (n=10) and high-frequency group (n=10). For a pretest, the respiratory muscle strength (MIP, MEP), quadriceps muscle activity (LF, VM, VL), and life quality (SGRQ) were measured. After applying NMES to each group for 30 minutes at a time, five times a week, for four weeks, a posttest was conducted in the same way as the pretest. RESULTS: Both groups showed significant differences in the respiratory muscle strength, quadriceps muscle activity, and quality of life within the groups and there were significant differences in the quadriceps muscle activity between the groups. CONCLUSION: The four-weeks NMES positively influenced the respiratory muscle strength and life quality by enhancing the function of the quadriceps and exercise tolerance. In particular, high-frequency(75 Hz) NMES was more effective than low-frequency (15 Hz) NMES. This result can be an alternative means to improve the physical functions of COPD patients clinically in the future.

EFFECT OF PATIENT'S BREATHING PATTERN ON THE STRESS CHANGES IN THIRD MOLAR EXTRACTION (제 3 대구치 발치시 환자의 호흡 패턴이 스트레스 변화 양상에 미치는 영향)

  • Rhee, Sang-Myung;Kim, Hyung-Wook;Park, Yang-Ho;Kim, Jin-Cheol;Park, Jun-Woo;Rhee, Sung-Jun;Nyamdorj, Selenge;Ahn, Jae-Mok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.485-493
    • /
    • 2007
  • Purpose: Heart rate variability(HRV) is the clinical consequence of various influences of the autonomic nervous system(ANS) on heart beat. HRV can estimate the potential physiologic rhythm from the interval between consecutive beats(RR interval or HRV data). It is known as RSA which represents respiration-related HR rhythmic oscillation. Previous studies demonstrated a specific breathing pattern(0.1Hz, 6breaths/min) to improve a physiological body condition related to the stress. In this paper, the level of stress would be evaluated in terms of three phases of the dental treatment, combined with 6breaths/min. Methods: These phases include before, during and after tooth extraction or anesthesia or something.36 patients' stresses were assessed using HRV stress analyzer in each phase in Kangdong Sacred Heart Hospital, and Chuncheon Sacred Heart Hospital, Hallym University Medical Center from Jun. to Sept. of 2007. HRV 5-min data collected were analyzed in time-domain and frequency-domain to evaluate the activity of autonomic nervous system(ANS) which represents the level of stress. Results: All HRV parameters including HF(high frequency), LF(low frequency) and LF/HF ratio showned a significant change affecting the ANS balance. There was a 6.4% difference between R(LF/HF)s on general breathing pattern for balance of Autonomic nervous system, but on controlled breathing pattern, 0.1Hz, was made narrow till 1.4%. The activity of ANS has increased by 1.4% on general breathing pattern, and by 2.9% on controlled breathing pattern, 0.1Hz. Conclusion: After analysis of preoperative stress changes and effect of breathing pattern of 0.1 Hz on the stress in 36 patients who have undergone third molar extraction, following was concluded. In the preoperative stage, the sympathetic change was the greatest?after the?anesthetic injection, and stress was relieved by controlling the breathing pattern to a frequency of 0.1Hz.

A Design of Wideband Frequency Synthesizer for Mobile-DTV Applications (Mobile-DTV 응용을 위한 광대역 주파수 합성기의 설계)

  • Moon, Je-Cheol;Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.40-49
    • /
    • 2008
  • A Frequency synthesizer for mobile-DTV applications is implemented using $0.18{\mu}m$ CMOS process with 1.8V supply. PMOS transistors are chosen for VCO core to reduce phase noise. The measurement result of VCO frequency range is 800MHz-1.67GHz using switchable inductors, capacitors and varactors. We use varactor bias technique for the improvement of VCO gain linearity, and the number of varactor biasing are minimized as two. VCO gain deterioration is also improved by using the varactor switching technique. The VCO gain and interval of VCO gain are maintained as low and improved using the VCO frequency calibration block. The sigma-delta modulator for fractional divider is designed by the co-simualtion method for accuracy and efficiency improvement. The VCO, PFD, CP and LF are verified by Cadence Spectre, and the sigma-delta modulator is simulated using Matlab Simulink, ModelSim and HSPICE. The power consumption of the frequency synthesizer is 18mW, and the VCO has 52.1% tuning range according to the VCO maximum output frequency. The VCO phase noise is lower than -100dBc/Hz at 1MHz at 1MHz offset for 1GHz, 1.5GHz, and 2GHz output frequencies.

Development of a Classification Model for Driver's Drowsiness and Waking Status Using Heart Rate Variability and Respiratory Features

  • Kim, Sungho;Choi, Booyong;Cho, Taehwan;Lee, Yongkyun;Koo, Hyojin;Kim, Dongsoo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.371-381
    • /
    • 2016
  • Objective:This study aims to evaluate the features of heart rate variability (HRV) and respiratory signals as indices for a driver's drowsiness and waking status in order to develop the classification model for a driver's drowsiness and waking status using those features. Background: Driver's drowsiness is one of the major causal factors for traffic accidents. This study hypothesized that the application of combined bio-signals to monitor the alertness level of drivers would improve the effectiveness of the classification techniques of driver's drowsiness. Method: The features of three heart rate variability (HRV) measurements including low frequency (LF), high frequency (HF), and LF/HF ratio and two respiratory measurements including peak and rate were acquired by the monotonous car driving simulation experiments using the photoplethysmogram (PPG) and respiration sensors. The experiments were repeated a total of 50 times on five healthy male participants in their 20s to 50s. The classification model was developed by selecting the optimal measurements, applying a binary logistic regression method and performing 3-fold cross validation. Results: The power of LF, HF, and LF/HF ratio, and the respiration peak of drowsiness status were reduced by 38%, 22%, 31%, and 7%, compared to those of waking status, while respiration rate was increased by 3%. The classification sensitivity of the model using both HRV and respiratory features (91.4%) was improved, compared to that of the model using only HRV feature (89.8%) and that using only respiratory feature (83.6%). Conclusion: This study suggests that the classification of driver's drowsiness and waking status may be improved by utilizing a combination of HRV and respiratory features. Application: The results of this study can be applied to the development of driver's drowsiness prevention systems.

Frontal Alpha Asymmetry, Heart Rate Variability, and Positive Resources in Bereaved Family Members with Suicidal Ideation after the Sewol Ferry Disaster

  • Jang, Kuk-In;Lee, Sangmin;Lee, Seung-Hwan;Chae, Jeong-Ho
    • Psychiatry investigation
    • /
    • v.15 no.12
    • /
    • pp.1168-1173
    • /
    • 2018
  • Objective After the Sewol ferry disaster, bereavement with suicidal ideation was a critical mental health problem that was accompanied by various neuropsychological symptoms. This study examined the frontal alpha asymmetry (FAA), heart rate variability (HRV), and several psychological symptoms in bereaved family members (BFM) after the Sewol ferry disaster. Methods Eighty-three BFM after the Sewol ferry disaster were recruited. We assessed FAA, HRV, and psychological symptoms, including depression, post-traumatic stress, post-traumatic growth factor, anxiety, grief, and positive resources, between BFM with the presence and absence of current suicidal ideation. Results Compared to BFM without suicidal ideation, BFM with suicidal ideation showed a higher FAA with right dominance. Significant differences in psychological symptoms were observed between the groups. In BFM with suicidal ideation, the low: high frequency (LF:HF) ratio correlated with social resources and support. Conclusion The FAA and LF:HF ratio may be biomarkers that represent the pathological conditions of BFM with suicidal ideation. If researched further, they may shed light on the interaction between bereavement with suicidal ideation and social resources for therapeutic intervention.

KOMPSAT-2 NON-UNIFORMITY CORRECTION ALGORITHM (다목적 실용위성2호의 NON-UNIFORMITY CORRECTION 알고리즘)

  • Park, Su-Young;Song, Jeong-Heon;Lee, Dong-Han;Seo, Doo-Chun;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.305-307
    • /
    • 2007
  • KOMPSAT-2(K-2) 의 MSC 는 CCD pixel 별 band 별 특성, 감도 및 시간에 따른 변화, CCD Geometry 등에 의해 왜곡 현상이 일어나며 위성 발사 전에 실험실에서의 충분한 실험과 Calibration 작업 을 통해 얻어진 값들을 사용하여 Image Restoration, 상대 복사 보정, 절대 복사 보정 등의 작업들을 거쳐서 왜곡 현상을 보정하게 된다. 그 중 복사 보정에 해당하는 NUC(NonUniformity Correction)은 MSC 각각의 픽셀들이 상이한 특성을 나타내는 것을 균일한 이미지로 보정하는 작업으로 무엇보다 우선시 되는 검보정 작업이다. K-2 NUC table 생성에는 시스템 특성상 몇 가지 사항을 고려 하여 위성에 upload 하는 high frequency NUC(HF NUC)과 지상국에서 처리할 수 있는 low frequency NUC(LF NUC)으로 구분하여 알고리즘을 생성하였다.

  • PDF

A Low-Jitter 2.5V 300MHZ CMOS PLL for Frequency Synthesizer (주파수 동기를 위한 저 잡음 2.5V 300Mhz CMOS PLL)

  • 권진규;이종화;조상복
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1189-1192
    • /
    • 2003
  • 본 논문에서는 노이즈를 고려한 PLL를 설계하였다. 30Mhz∼300Mhz으로 동작하는 VCO를 설계하였다. VCO를 평균 250Mhz으로 동작하도록 하고 reference 주파수, 62.5Mhz로 locking하는 PLL를 설계를 하였다. 300Mhz PLL의 기본적인 구조로 PLL은 PFD(Phase frequency detector), CP(Charge Pump), LF(Loop filter), VCO(Voltage controlled Oscillator)와 Divider로 구성되었다. PFD과 CP는 Dead Zone를 줄이고, 큰 gm를 가지도록 설계를 하였다. PLL에서 가장 중요한 블락인, VCO는 One Chip으로 설계하기 위해 Ring Oscillator로 설계를 하였다. 2.5V 62.5MHZ의 외부 신호를 300MHZ을 발진하는 VCO에서 분주하여 clock synthesizer를 설계하였다. 본 논문은 Hynix0.25공정을 사용하여 설계를 하였으며, 2.5V의 공급 전원을 사용하였다.

  • PDF

High Frequency Link PCS for Interfacing with Power Utility System (고주파 링크 전력계통 연계형 PCS)

  • Kim, E.S.;Yoon, G.H.;Kang, S.I.;Cha, I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • Recently, new technologies of the PCS (Power Conditioning System) for energy generating using solar cells or fuel cell are required for smaller unit with low cost and high performance. In this paper, the proposed high frequency AC linked DC/AC converter which consisted of LLC resonant and LF cycloconverter is presented, described and verified through the experimental results of 1kW PCS.

  • PDF

Improvement of Solder Joint Strength in SAC 305 Solder Ball to ENIG Substrate Using LF Hydrogen Radical Treatment (SAC 305솔더와 ENIG 기판의 접합강도에 미치는 저주파 수소라디칼처리의 영향)

  • Lee, Ah-Reum;Jo, Seung-Jae;Park, Jai-Hyun;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.99-106
    • /
    • 2011
  • Joint strength between a solder ball and a pad on a substrate is one of the major factors which have effects on electronic device reliability. The effort to improve solder joint strength via surface cleaning, heat treatment and solder composition change have been in progress. This paper will discuss the method of solder ball joint strength improvement using LF hydrogen radical cleaning treatment and focus on the effects of surface treatment condition on the solder ball shear strength and interfacial reactions. In the joint without radical cleaning, voids were observed at the interface. However, the specimens cleaned by hydrogen-radical didn't have voids at the interface regardless of cleaning time. The shear strength between the solder ball and the pad was increased over 120%(about 800gf) when compared to that without the radical treatment (680gf) under the same reflow condition. Especially, at the specimen treated for 5minutes, ball shear strength was considerably increased over 150%(1150gf). Through the observation of fracture surface and cross-section microstructure, the increase of joint strength resulted from the change of fracture mode, that is, from the solder ball fracture to IMC/Ni(P) interfacial fracture. The other cases like radical treated specimen for 1, 3, 7, 9min. showed IMC/solder interfacial fracture rather than fracture in the solder ball.