• Title/Summary/Keyword: LED unit

Search Result 457, Processing Time 0.028 seconds

A Mixed Integer Linear Programming Approach for the Profit Based Unit Commitment Problem under Non-Linear Fuel Consumption Constraint and Maintenance Cost (비선형 연료 제약 및 유지보수 비용을 고려한 Mixed Integer Linear Programming 기반 발전기 주간 운용계획 최적화)

  • Song, Sang-Hwa;Lee, Kyung-Sik
    • Korean Management Science Review
    • /
    • v.25 no.1
    • /
    • pp.43-53
    • /
    • 2008
  • This paper considers a profit-based unit commitment problem with fuel consumption constraint and maintenance cost, which is one of the key decision problems in electricity industry. The nature of non-linearity inherent in the constraints and objective functions makes the problem intractable which have led many researches to focus on Lagrangian based heuristics. To solve the problem more effectively, we propose mixed integer programming based solution algorithm linearizing the complex non-linear constraints and objectives functions. The computational experiments using the real-world operation data taken from a domestic electricity power generator show that the proposed algorithm solves the given problem effectively.

Development of a Tracked Vehicle Model for Real-time Simulation of Semi-active Suspension System (반능동 현수장치의 실시간 시뮬레이션용 궤도차량 모델 개발)

  • 손영일;이종호;송병석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.135-143
    • /
    • 2003
  • In this study, a real-time simulation model was developed for tracked vehicles with in-arm type semi-active hydro-pneumatic suspension unit using MATLAB S-functions. Since the vehicle model uses relative coordinates and massless link elements, the developed model has an enhanced analytic time performance. Through the comparison of simulation results with multi-body software(DADS), the vehicle model is verified. A controller using on-off skyhook control algorithm is designed with the pilot-centre]led proportional valve based on conventional damper characteristics. Exploiting the developed tracked vehicle model with other subsystem model such as a controller model, a suspension unit model, and a test road model, computer simulations are carried out. Control simulation results with the developed tracked vehicle model show that the semi-active suspension control system has a better performance than the conventional suspension system.

Clinical considerations in the use of dental light curing unit (광중합의 시작, 어떤 광조사기를 어떻게 사용해야할까?)

  • Lee, Chang-Ha
    • The Journal of the Korean dental association
    • /
    • v.57 no.3
    • /
    • pp.175-184
    • /
    • 2019
  • Increasing the aesthetic needs of patients and decreasing the use of amalgam had led to increased demand for dental resin composite. Thereby, light curing unit (LCU) has become an essential equipment in dental clinic. To ensure long-term prognosis of photopolymerized materials, LCU should have a uniform and consistent radiant output and an emission spectrum that includes the active wavelength range of photoinitiators. In addition, when the correct use and thorough maintenance and repair of LCU are performed, the higher success rate of restoration using photopolymerization materials will be achieved.

  • PDF

Design and Development of a Medical Education System Using Information Technology: A Case Report from the Pusan National University School of Medicine (정보기술을 활용한 의학교육시스템의 설계와 개발: 부산대학교 의학전문대학원 사례)

  • Im, Sun Ju;Lee, Sang Yeoup;Baek, Sun Yong;Woo, Jae Seok;Kam, Beesung
    • Korean Medical Education Review
    • /
    • v.16 no.1
    • /
    • pp.16-24
    • /
    • 2014
  • The development of information technology (IT) has led to changes in medical education. IT has been used for e-learning and e-teaching, e-assessment, e-logistics, and e-administration. Pusan National University School of Medicine has developed its own educational information system using IT to support students' learning and assessment and to manage curricular activities. Based on our experience, we propose six suggestions for designing new software, specifically regarding simplifying the design for users, communication with the programmer, a rapid cycle from design to implementation, orientation support for users, backup and security support, and obtaining patents. Collaborating with the Department of Medical Informatics within the School of Medicine has advantages, and an alliance among medical schools can simplify the development of software. In any case, curricular innovation should precede the introduction of technology because all technologies should support curricular goals.

Implementation of Portable Visible Light Receiver using USB OTG (USB OTG를 활용한 휴대용 가시광 수신기 구현)

  • Lee, Dae-Hee;Lee, Jong-Sung;Oh, Chang-Heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.741-743
    • /
    • 2017
  • The visible light communication is a communication method of outputting binary data based on the illumination threshold value at the light receiving diode of the receiving unit, when the LED of the transmitting unit transmits light. However, separate receiver is necessary to receive the optical signal, there is a problem that a device not equipped with such a receiver can not utilize visible light communication. To solve this problem, this paper proposes a portable visible light receiver applicable to devices using USB OTG. Implemented portable visible light receiver converts the binary data received from the LED into a character string of ASCII code and transmits it to another device. Through data transmission experiments using smart phone confirmed that it is possible to transmit ASCII codes in the proposed method.

  • PDF

Analysis of Quality Improvement of a Floating Image Using a Hybrid Retroreflective Mirror Array Sheet (혼성-병풍형 구조의 재귀반사 거울 배열판을 이용한 부양영상 개선 분석)

  • Yu, Dong Il;Baek, Young Jae;Yong, Hyeon Joong;O, Beom Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.142-145
    • /
    • 2019
  • Normally, a corner cube retroreflector (CCRR) sheet is used as a retroreflective mirror array (RRMA) in a volumetric display. Each CCRR unit reflects light in the retroreflective direction, which is parallel to the incident light, and it makes a blurred image, as it shifts the position of light within its dimensions. Adopting a "curved planar wall" and "parabolic focusing" (x-axis), a hybrid-t(transverse direction)-RRMA is proposed, to improve the image quality and brightness. The improvement of image contrast is achieved by tuning a "linear v-shaped groove" structure to a "parabolic v-shaped groove". Also, the system has been simplified and the brightness enhanced 4 times by removing the half mirror.

Backlight Unit adopting high power RGB-LEDs (고출력 RGB-LED를 사용한 Backlight 개발)

  • Lee, Han-Jin;Park, Doo-Sung;Han, Jeong-Min;Park, Jeong-Kuk;Bae, Kyung-Woon;Kim, Seo-Yoon;Kim, Yun-Ho;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1038-1042
    • /
    • 2003
  • LED(Light Emitting Diodes)를 이용한 LCD 백라이트는 현재까지 모바일용의 $2{\sim}3$ 인치정도의 소형모델에서 상용화되고있다. 현재 동종분야에서 $5{\sim}7$ 인치 이상의 중대형에서는 아직 검토나 개발단계인 것으로 파악되고 있다. LED의 특징인 장수명, 고색순도, Robustness 등의 장점에도 불구하고 광효율이나 경제적측면에서 아직 형광램프 Type 에 비해 개선점이 남아있는 것도 개발지연 이유중의 하나다. 최근에 일부 광원업체에서 소비전력 5W로 높은 출광효율을 갖는 고휘도를 가진 LED가 개발되고있다. 고색재현성을 요구하는 TV등의 민수용 디스플레이시장이 커지는 현 추세에 한 방법으로 3색의 고휘도 LED광원을 사용한 백 라이트를 개발했다. R(Red), G(Green), B(Blue)의 3색 점광원 다수를 이중도광판 구조의 장변에 일정 간격으로 배열하여 최종 출사면에서 백색이 되도록 소정의 구성비로 설계하였다. 점광원간의 간격으로 인해 발생되는 혼색도를 보완하기위해 광원과 출사면까지의 광경로를 점광원이 아닌 튜브형의 형광광원 사용시보다 일정량 길게 설계해야 되는데, 이것으로 인해 출광효율이 형광램프구조에 비해 떨어지는 결과로 나타났다. 본 연구에서는 17인치 모니터구조의 백라이트에서 색재현성 105%와 소비전력 67W에서 표면휘도 $2000cd/m^2$ 정도를 달성하였다.

  • PDF

Estimation of Spatial Variations in a Light Source by Optical Fiber Sensory System (광섬유를 이용한 광원 위치의 미세 변위 추정)

  • Kim, Ji-Sun;Jung, Gu-In;Lee, Tae-Hee;Choi, Ju-Hyeon;Oh, Han-Byeol;Kim, A-Hee;Park, Hee-Jung;Kim, Kyung-Seop;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1283-1289
    • /
    • 2013
  • The purpose of this study is to find the new method for estiming the spatial variations in a light source with utilizing the optical fiber sensory system. With this aim, firstly the asymmetry in the beam profile of a light source is evaluated by using the tipped optical fiber with 0, 10, 20, 30, 40, 45-degree angle. Secondly the variation of position in a light source is estimated by adjusting the relative position between the light source unit (XYZ stage, LED, Optical fiber) and the receiver unit (Photodiode, XYZ stage). Our experimental results show that the spatial variation of a light source can be resolved in terms of the variations in beam profile with varying the tip angle of an optical fiber and adjusting the relative distance between the light source unit and the receiver.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Effect of infection control barrier thickness on light curing units (감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향)

  • Chang, Hoon-Sang;Lee, Seok-Ryun;Hong, Sung-Ok;Ryu, Hyun-Wook;Song, Chang-Kyu;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • Objectives: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. Materials and Methods: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eightfold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. Results: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). Conclusions: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.