• Title/Summary/Keyword: LC-ESI-MS/MS

Search Result 213, Processing Time 0.029 seconds

Quantification Analysis and Antioxidant Activity of Leejung-tang (LC-MS/MS를 이용한 이중탕(理中湯)의 정량분석 및 항산화 활성)

  • Seo, Chang-Seob;Kim, Ohn Soon;Kim, Yeji;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.177-185
    • /
    • 2013
  • Objectives : Leejung-tang (Lizhong-tang) has been used for treatment of gastrointestinal disorders in Korea. In this study, we performed quantification analysis of five marker components, liquiritin, ginsenoside Rb1, ginsenoside Rg1, glycyrrhizin, and 6-gingerol in Leejung-tang using a ultra performance liquid chromatography- electrospray ionization-mass spectrometer (UPLC-ESI-MS). In addition, we evaluated antioxidant activity of Leejung- tang. Methods : The column for separation of five constituents used a UPLC BEH C18 ($100{\times}2.1mm$, $1.7{\mu}m$) maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in H2O (A) and CH3CN (B) by gradient flow. The flow rate was 0.3 mL/min with detection at mass spectrometer. The antioxidative activities conduct an experiment on 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 2,2-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activities of Leejung-tang. Results : Calibration curves of five marker compounds were acquired with r2 values > 0.99. The amount of the five compounds in Leejung-tang were 0.07 - 0.84 mg/g. The concentration required for 50% reduction (RC50) against ABTS radical was 119.02 ug/mL. In addition, the scavenging against DPPH radical of Leejung-tang was 11.4%, 14.5%, 19.8%, 29.6%, and 49.2% at 25 ug/mL, $50{\mu}g/mL$, $100{\mu}g/mL$, $200{\mu}g/mL$, and $400{\mu}g/mL$, respectively. Conclusions : The established LC-MS/MS method will be helpful to improve quality control of Leejung-tang. In addition, Leejung-tang is a potential antioxidant therapeutic agent.

Simultaneous Determination of Three Compounds in Ejung Tang by HPLC-DAD and LC-ESI-MS (HPLC를 이용한 이중탕 중 3종 활성성분의 동시분석법 확립)

  • Lee, Bo-Hyoung;Ma, Jin-Yeul;Weon, Jin-Bae;Yang, Hye-Jin;Yun, Bo-Ra;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • An accurate and sensitive analysis method was established for simultaneous determination of three bioactive compounds (glycyrrhizin, 6-gingerol and ginsenoside Rg3) in the Ejung Tang with high-performance liquid chromatography (HPLC)-photodiode array detection (DAD)-electrospray ionization (ESI)-Mass spectrometry (MS). The optimizing chromatographic separations a were acquired by an $C_{18}$ column ($5{\mu}m$, $4.6I.D{\times}250mm$, SHISHEDO) using gradient elution with water comprising 0.1% TFA(trifluoroacetic acid) and acetonitrile at a performing temperature of $35^{\circ}C$. Flow rate was 1.0 ml/min. A detection UV wavelength set at 205 nm and 250 nm. The three compounds were identified by electrospray ionization mass spectrometry. All calibration curves indicated great linear regression within test ranges ($R^2>0.9997$). The established method provided acceptable precision and accuracy. The relative standard deviations (RSDs) of intra-day and inter-day were less than 2.00% and 3.00%, respectively. The recoveries were found to range from 94.49 to 101.10% for the three compounds analyzed. These results showed that this method was effective and reliable for quality control of Eiung-Tang.

High Accuracy Mass Measurement Approach in the Identification of Phospholipids in Lipid Extracts: 7 T Fourier-transform Mass Spectrometry and MS/MS Validation

  • Yu, Seong-Hyun;Lee, Youn-Jin;Park, Soo-Jin;Lee, Ye-Won;Cho, Kun;Kim, Young-Hwan;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1170-1178
    • /
    • 2011
  • In the present study, the approach of high accuracy mass measurements for phospholipid identifications was evaluated using a 7 T ESI-FTMS/linear ion trap MS/MS. Experiments were carried out for porcine brain, bovine liver, and soybean total lipid extracts in both positive and negative ion modes. In total, 59, 55, and 18 phospholipid species were characterized in the positive ion mode for porcine brain, bovine liver, and soybean lipid extracts, respectively. Assigned lipid classes were PC, PE, PEt, PS, and SM. In the negative ion mode, PG, PS, PA, PE, and PI classes were observed. In the negative ion mode, for porcine brain, bovine liver, and soybean lipid extracts, 28, 34, and 29 species were characterized, respectively. Comparison of our results with those obtained by other groups using derivatization-LC-APCI MS and nano-RP-LC-MS/MS showed that our approach can characterize PC species as effectively as those methods could. In conclusion, we demonstrated that high accuracy mass measurements of total lipid extracts using a high resolution FTMS, particularly, 7T FTMS, plus ion-trap MS/MS are very useful in profiling lipid compositions in biological samples.

Quality Characteristics of Dolsan Leaf Mustard according to Various Blanching Conditions and Liquid Chromatography with Photodiode Array and Tandem Mass Spectrometry Analysis (다양한 데침조건에서 돌산갓의 이화학적 특성 및 LC-PDA/MS/MS 분석)

  • Son, Hae-Reon;Oh, Sun-Kyung;Tsukamoto, Chigen;Choi, Myeong-Rak
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study aims to examine the optimum blanching conditions as a pretreatment condition to improve the storage stability of Dolsan leaf mustard pickle. The effects of the blan- ching temperature and time were investigated at a temperature range of $80-100^{\circ}C$. Sampling was done for 1 month after a 5 days interval. The L value of the Dolsan leaf mustard was found to be the highest at $80^{\circ}C$. The cutting force increased as the blanching temperature increased. The tensile strength decreased at $95^{\circ}C$ and $100^{\circ}C$. In addition, the sensory evaluation scores were the best at $80^{\circ}C$. The storage stability was assessed at various blanching temperatures to increase the sinigrin content during storage. Liquid chromatography with photodiode array and tandem mass spectrometry (LC-PDA/MS/MS) analysis was conducted to identify and quantify the sinigrin content in the Dolsan leaf mustard. Sinigrin as an internal standard was co-injected into each sample solution. The sample was monitored by recording the ultraviolet absorbance at 228 nm and by electrospray ionization (ESI) positive ion mode in the m/z 50-1,500 range. Blanching the sample at $80^{\circ}C$ showed the highest sinigrin concentration during storage among various temperatures and the maximum concentration was 350 ppm at 15 days storage. Study on utilization of vegetable from food processing of leaf mustard and preservation conservation results suggest that blanching at $80^{\circ}C$ is expected to improve the palatability of the pickle.

Structural characterization and degradation efficiency of degradation products of iopromide by electron beam irradiation (전자선 처리 후 생성된 Iopromide의 분해산물 구조 규명 및 분해 효율)

  • Ham, Hyun-Sun;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.292-299
    • /
    • 2014
  • Iopromide is an X-ray contrast agent that has been detected frequently with high concentration level in surface waters. Structural characterization of degradation products and measurement of degradation efficiency of iopromide by an electron beam irradiation were performed. For the fortified sample with iopromide, electron beam irradiation (UELV-10-10S, klysotrn, 10 MeV, 1 mA and 10 kW) was performed. The chemical structures of I_D_665 and I_D_663, which are degradation products of iopromide, were proposed by interpretation of mass spectra and chromatograms by LC/ESI-MS/MS. The mass fragmentation pathways of mass spectra in tandem mass spectrometry were also proposed. Iopromide was degraded 30.5~98.4% at dose of 0.3~5 kGy, and 97.8~30% in the concentration range $0.5{\sim}100{\mu}g/kg$ at electron beam dose of 0.3 kGy, respectively. Thus, increased degradation efficiency of iopromide by electron beam irradiation was observed with a higher dose of electron beam and lower concentration.

Electrospray Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Gliquidone in Human Plasma (Electrospray Tandem Mass를 이용한 혈중 글리퀴돈의 정량법 개발 및 생체이용률시험)

  • Moon Chul-Jin;Lee Eun-Hee;Yang Song-Hyun;Moon Hae-Ran
    • YAKHAK HOEJI
    • /
    • v.49 no.3
    • /
    • pp.212-216
    • /
    • 2005
  • A rapid, sensitive and selective electrospray tandem mass spectrometric (ESI-LC/MS/MS) method for the quantitation of gliquidone in human plasma was developed. A bioavailability study of gliquidone tablet (30 mg gliquidone, Boehringer Ingelheim Korea Co.) was performed using the validated ESI-LC/MS/MS method. The dose of 30 mg of gliquidone (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, 24, and 33 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $10\~1000 ng/ml$. The coefficient of variation for intra- and inter-day assay were $8.30\~18.86$, and $2.19\~12.92\%$, respectively. The lower limit of quantification for gliquidone was 10 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 3861.17$\pm$1328.61 ng-hr/ml, $C_{max}$ was 831.02$\pm$227.99 ng/ml, $T_{max}$ was $2.94{\pm}0.77 hr,\;K_e$, was 0.19$\pm$0.06 1/hr, and $t_{l/2}$ was 4.47$\pm$3.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of gliquidone dosage forms was prepared successfully and could be used for the bioequivalence test of gliquidone preparation.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

Isolation and Identification of an Unauthorized Sildenafil Analogue in a Commercial Functional Food (시판 기능성식품으로부터의 실데나필 유도체 부정첨가물질의 분리 및 구조규명)

  • Baek, Du-Jong
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.443-446
    • /
    • 2010
  • HPLC analysis of a commercial herb drink marketed as a functional food revealed to contain an unauthorized substance similar to sildenafil, the active ingredient of the prescription drug Viagra$^{(R)}$ approved for the treatment of male erectile dysfunction. In order to identify the illegal additive, the herb drink was extracted with methylene chloride, and the extract was purified further using semipreparative HPLC. The chemical structure of the isolated substance was elucidated based on IR, LC/MS-ESI, and NMR spectroscopy, which showed the characteristics similar to sildenafil with minor modification. The only difference was the substitution of the methylpiperazine moiety of sildenafil to the hydroxyethylpiperazine group of the illegal additive.

Simultaneous determination of preservatives in sausages using liquid chromatography with electrospray ionization tandem mass spectrometry (LC-MS/MS를 이용한 소시지 중 보존료 동시분석)

  • Koh, Ba-Ra-Da;Kim, Ji-Yeon;Jang, Mi-Sun;Seo, Doo-Ri;Jung, Bo-Ram;Shin, Ji-Hyun;Lim, Jin-Taek;Kim, Yong-Hwan;Kim, Eun-Sun
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • A simultaneous determination method was developed for nine preservatives (benzoic acid, sorbic acid, dehydroacetic acid, methyl-, ethyl-, isopropyl-, propyl-, isobutyl- and butyl-parabens) in sausage by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Each parameter was established by multiple reaction monitoring in negative mode. Separation was achieved on a phenyl-hexyl ($2.5{\mu}m$, $2.1{\times}150mm$, Waters) with A-20 mM ammonium acetate containing 0.1% acetic acid in water, B-Acetonitrile as mobile phase with gradient mode at a flow rate of 0.3 mL/min. The developed method was validated for specificity, linearity, accuracy and precision in sausages samples. Linearity was over 0.998 with calibration curve of the mixed standards. The mean recoveries from sausages fortified at the level of 2.0~10.0 mg/L were in range of 98.60~109.16% with RSDs lower than 8.93%. The limits of detection (LOD) and the limits of quantification (LOQ) were in the range between 0.0003~0.085 mg/L and 0.01~0.257 mg/L, respectively. Intra-day precision and inter-day precision were 0.45~6.16% and 2.81~13.33%, respectively. Using presently developed determination method, 33 field sausage samples from Gwangju city in Korea were screened over nine preservatives. As a result, no preservatives were detected in all samples.