• Title/Summary/Keyword: LC Resonant

Search Result 143, Processing Time 0.046 seconds

Vector Control of IM with The Cycloconverters using High Frequency LC Resonant Circuits (LC 고주파공진회로를 이용한 사이크로콘버터에 의한 유도전동기의 벡터제어)

  • Choi, Jung-Soo;Cho, Kuy-Min;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.680-682
    • /
    • 1993
  • In this paper, rotor flux feedforward control of induction motor fed by cycloconverters with high frequency LC resonant circuits is presented. The cycloconverter using new current control algorithm as a power source of induction motor drive system is proposed. And then its validity of the application to induction motor control system is verified by experimental results.

  • PDF

A High Efficiency Bidirectional Resonant Converter With Auxilary LC Circuit for V2G System (V2G 시스템을 위한 보조 LC 회로를 가진 고효율 양방향 공진형 컨버터)

  • Tranand, Duc-Hung;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.323-324
    • /
    • 2016
  • In this paper a high efficiency bidirectional resonant converterfor Vehicle-to-Grid applications (V2G) is proposed.The proposed converter has adopted an LC auxiliary circuit in the third winding of the transformer. With the proposed method full softswitching can be ensured in all switches over a wide range of loadsand the secondary ringing can be removed with no additional snubber or clamp circuitry.In addition, since the proposed resonant converter is able to operate at an almost constant resonant frequencyregardless of the load, CC/CV charge of the battery can be simply implemented with high efficiency. A 3.3 kW bidirectional converter for On-Board Charger of Electric Vehicle is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both charge and discharge mode. The maximum efficiency of the proposed system was 98.13 % at 2.3 kW during the constant voltage mode charge operation.

  • PDF

Design and Fabrication of Implantable LC Resonant Blood Pressure Sensor (인체 삽입용 LC 공진형 혈압 센서 디자인 및 제작)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.171-176
    • /
    • 2013
  • In this paper, we present a MEMS (micro-electro-mechanical system) implantable blood pressure sensor which has designed and fabricated with consideration of size, design flexibility, and wireless detection. Mechanical and electrical characterizations of the sensor were obtained by mathematical analysis and computer aided simulation. The sensor is composed of two coils and a air gap capacitor formed by separation of the coils. Therefore, the sensor produces its resonant frequency which is changed by external pressure variation. This frequency movement is detected by inductive coupling between the sensor and an external antenna coil. Theoretically analyzed resonant frequency of the sensor under 760 mmHg was calculated to 269.556 MHz. Fused silica was selected as sensor material with consideration of chemical and electrical reaction of human body to the material. $2mm{\times}5mm{\times}0.5mm$ pressure sensors fitted to radial artery were fabricated on the substrates by consecutive microfabrication processes: sputtering, etching, photolithography, direct bonding and laser welding. Resonant frequencies of the fabricated sensors were in the range of 269~284 MHz under 760 mmHg pressure.

A Study on the Polarity Changing Method without Dead Time of a Cycloconverter with an LC Resonant Circuit (LG 공진회로를 이용한 사이크로컨버터의 휴지기간 없는 극성절환 방법에 관한 연구)

  • Choi, Jung-Soo;Cho, Kyu-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.9
    • /
    • pp.111-117
    • /
    • 1998
  • This paper presents a polarity changing method without dead time of a cycloconverter with an LC resonant circuit. According to the proposed method, dead time to prevent short circuit for the polarity changing is not required. Therefore the delay of control and the harmonic components of output currents can be decreased. And the proposed method can be expanded for the other natural commutated cycloconverters of noncirculating current type. In this paper, the switching method of the proposed polarity changing without dead time is studied, and in order to confirm the validity of the proposed method the experiment is carried out with a cycloconverter with an LC resonant circuit.

  • PDF

The Study of Ripple Reduction of the PFC CCM Flyback Converter without Electrolytic Capacitor for LED Lightings using LC Resonant Filter (LC 공진 필터를 이용한 전해 커패시터 없는 LED 구동용 PFC CCM 플라이백 컨버터의 출력 전류 리플 저감에 관한 연구)

  • KIm, Choon-Tack;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.601-610
    • /
    • 2016
  • The light-emitting diode (LED) has been used in a variety of industrial fields and for general 0lighting purposes on account of its high efficiency, low power consumption and long lifespan. The LED is driven by direct current; therefore, an AC/DC converter is typically required for its use. An electrolytic capacitor is generally used for stabilizing DC voltage during use of the AC/DC converter. However, this capacitor has a short lifespan, which makes it a limiting factor in LED lighting. Furthermore, LED lighting requires a dimmable control to enable energy savings and fulfil a growing consumer demand. In this paper, the dimmable single-stage power factor correction (PFC) continuous conduction mode (CCM) flyback converter that employs no electrolytic capacitor is presented. The LC resonant filter is alternatively applied to reduce the 120[Hz] ripple on the output. And the optimum value of the LC resonant filter parameters considering both efficient and performance is analysed. Simulation and experimental results verify the satisfactory operation of the converter.

Performance Analysis for Auxiliary Resonant Commutated Pole Inverter with Clamping Diodes (클램핑 다이오드를 갖는 ARCP 인버터의 성능 분석)

  • Lee, Yoon-Seok;Kim, Jae-Hyuk;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1611-1618
    • /
    • 2018
  • This paper proposes a new auxiliary resonant commutated pole (ARCP) inverter which has a modified auxiliary circuit. The proposed auxiliary circuit includes two auxiliary IGBT switches, an LC resonant circuit, and two clamping diodes. In order to analyze the performance of proposed ARCP inverter, computer simulations with PSCAD, and hardware experiments were carried out. Through analyzing the experimental results, it is known that the proposed ARCP inverter offers efficiency improvement of 1.5% compared with the hard-switching inverter.

The Analysis of Dual Resonant Iris for Designing Waveguide Band-Pass Filter (대역 통과 도파관 여파기 설계를 위한 이중 공진 아이리스 해석)

  • Choi, Jin-Young;Kim, Byung-Mun;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.904-911
    • /
    • 2011
  • This paper deals with transmission characteristics of a new dual resonant structure for designing waveguide band-pass filter. The structure which has a pass-band between two adjacent stop-bands in a single body consists of circular ridged aperture and four armed conducting patch. The dual resonant behavior of the structure can be represented by a combination of LC series and parallel resonant circuits. Also these resonant properties can be easily controlled by varying the geometry of the aperture and four armed conducting patch. Actually, the structure is fabricated on the microstrip substrate by use of etching technique so that it is formed an iris type resonator which can be easily put into the transverse plane of the waveguide. We use WR-90 standard waveguide, adapters, and VNA(vector network analyzer) to measure the resonant characteristics of the structure. It is very useful to design and to improve the cutoff skirts characteristics in the waveguide band-pass filter design area.

Analysis and Implementation of LC Series Resonant Converter with Secondary Side Clamp Diodes under DCM Operation for High Step-Up Applications

  • Jia, Pengyu;Yuan, Yiqin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.363-379
    • /
    • 2019
  • Resonant converters have attracted a lot of attention because of their high efficiency due to the soft-switching performance. An isolated high step-up converter with secondary-side resonant loops is proposed and analyzed in this paper. By placing the resonant loops on the secondary side, the current stress for the resonant capacitors is greatly reduced. The power loss caused by the equivalent series resistance of the resonant capacitor is also decreased. Clamp diodes in parallel with the resonant capacitors ensure a unique discontinuous current mode in the converter. Under this mode, the active switches can realize soft-switching during both turn-on and turn-off transitions. Meanwhile, the reverse-recovery problems of diodes are also alleviated by the leakage inductor. The converter is essentially a step-up converter. Therefore, it is helpful for decreasing the transformer turn-ratio when it is applied as a high step-up converter. The steady-state operation principle is analyzed in detail and design considerations are presented in this paper. Theoretical conclusions are verified by experimental results obtained from a 500W prototype with a 35V-42V input and a 400V output.

Design Consideration of Half-Bridge LLC Resonant Converter

  • Choi, Hang-Seok
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.13-20
    • /
    • 2007
  • LLC resonant converters display many advantages over the conventional LC series resonant converter such as narrow frequency variation over wide range of load and input variation and zero voltage switching even under no load conditions. This paper presents analysis and design consideration for the half bridge LLC resonant converter. Using the fundamental approximation, the gain equation is obtained, where the leakage inductance in the transformer secondary side is also considered. Based on the gain equation, the practical design procedure is investigated to optimize the resonant network for a given input/output specifications. The design procedure is verified through an experimental prototype of the 115W half-bridge LLC resonant converter.

Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor (LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정)

  • Choi, Won-Seok;Kim, Jin-Tae;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.