• Title/Summary/Keyword: LAMP2

Search Result 1,123, Processing Time 0.03 seconds

A study on the removing of contaminants by TiO2 coating and CaO additive (TiO2 코팅과 CaO 첨가에 따른 독성물질 제거에 관한 연구)

  • Woo, Insung;Lee, Geonduk;Hwang, Myungwhan;Lee, Hongju
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • This study shows an air-purification test by the UV lamp on which TiO2 catalyst is deposited with glass fiber in the reactor chamber. This test was based on the fundamental data of air-purifier as assessing a removing ability on various contaminants such as CH3COOH, NH3, NO and SO2 as variation of the TiO2 coating, the wave of UV lamp, and the additive CaO. As a result, the highest decomposing removal ratio was shown when 5-times coated glass fiber was used. It can be due to the recombination reaction of electrons and electron-hole in the loaded CaO. Thus, the decomposing removal ratio increased as the recombination ratio decreased. In addition, it was confirmed that the decomposing removal ratio lowered when CaO was considerably deposited because it hided the lamp of OH-1 radical.

Photochemical Degradation of Dimethyl Phthalate by Fe(III)/tartrate/H2O2 System

  • Feng, Xianghua;Ding, Shimin;Xie, Faping
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3686-3690
    • /
    • 2012
  • Photochemical degradation of dimethyl phthalate (DMP) in Fe(III)/tartrate/$H_2O_2$ system was investigated utilizing fluorescent lamps as the primary light source. Effects of initial pH, light source, and initial concentration of each reactant on DMP photodegradation was examined. The results show that the system was able to effectively photodegrade DMP utilizing visible light. Fluorescent lamp, halide lamp, UV lamp and sunlight could all be used as the light sources. The optimal pH ranged among 3.0-4.0 for the system. Increases of the initial concentrations of Fe(III) and $H_2O_2$ accelerated the photodegradation of DMP, whereas excessively high initial tartrate concentration resulted in the decrease of photodegradation efficiency and rate of DMP.

The analysis of neutral particle in Mercury discharge lamp

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2421-2423
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm $(6^3S_1{\rightarrow }6^3P_2)$ were larger than 404.8nm $(6^3S_1{\rightarrow}6^3P_1)$. According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

Electron Mobility Calculations for the Positive Column of a Fluorescent Lamp (형광램프 양광주 내의 전자이동도 계산)

  • 지철근;장우진;이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.2
    • /
    • pp.55-58
    • /
    • 1988
  • Electron mobility which is a basic parameter to represent gas state, is calculated for 38mm 20W fluorescent lamp. 2 Electron Group Model is u&ed for electron distribution function. To prove this result electron mobility in 38mm 20W fluorescent lamp is measured at various wall temperatures. In order to obtain electric field strength of positive column, the sum of anode and cathode fall voltages assumed to be 15(VJ) and dual slit is used to measure positive column length. The measured and calculated result is potted under $10-80^{\circ}C$ wall temperature.

  • PDF

A Study on the Numerical Analysis of Heat Sink for Radiant Heat of Automotive LED Head Lamp (자동차 LED Head Lamp의 방열을 위한 Heat Sink의 수치해석적 연구)

  • Choi, Byung-Hui;Kim, Chang-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4398-4404
    • /
    • 2012
  • This thesis was conducted a numerical analysis on the radiant heat performance according to factors of design of heat sink for cooling of the automotive LED head lamp. The heat sinks were designed with 5 different types to fit the limited internal space by formula based on an existing product (Type 1). Designed heat sinks of five types were analyzed by ANSYS CFD V12.1, and the analysis results were compared with the existing type. The results of simulation were analyzed temperature distribution and average temperature, air flow characteristic, heat flux etc. This thesis was researched on the correlation of the cooling performance according to the heat sink structure and the fin shape. Through numerical analysis, could be confirmed heat sink Type 2 as the best results.

Sensitive and Rapid Detection of Giardia lamblia Infection in Pet Dogs using Loop-Mediated Isothermal Amplification

  • Li, Jie;Wang, Peiyuan;Zhang, Aiguo;Zhang, Ping;Alsarakibi, Muhamd;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.2
    • /
    • pp.237-241
    • /
    • 2013
  • Giardia lamblia is recognized as one of the most prevalent parasites in dogs. The present study aimed to establish a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of G. lamblia from dogs. The fecal samples were collected and prepared for microscopic analysis, and then the genomic DNA was extracted directly from purified cysts. The concentration of DNA samples of G. lamblia were diluted by 10-fold serially ranging from $10^{-1}$ to $10^{-5}ng/{\mu}l$ for LAMP and PCR assays. The LAMP assay allows the amplification to be finished within 60 min under isothermal conditions of $63^{\circ}C$ by employing 6 oligonucleotide primers designed based on G. lamblia elongation factor 1 alpha ($EF1{\alpha}$) gene sequence. Our tests showed that the specific amplification products were obtained only with G. lamblia, while no amplification products were detected with DNA of other related protozoans. Sensitivity evaluation indicated that the LAMP assay was sensitive 10 times more than PCR. It is concluded that LAMP is a rapid, highly sensitive and specific DNA amplification technique for detection of G. lamblia, which has implications for effective control and prevention of giardiasis.

Effects of Light Trap Structure and Lamp Type on the Attraction of Chestnut Pests in an Orchard (밤재배원에서 유살등 구조 및 램프의 종류가 해충 유인력에 미치는 영향)

  • Kim, Young-Jae;Kim, Hyun Kyung;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.3
    • /
    • pp.217-223
    • /
    • 2014
  • The effects of insect capture were studied in a chestnut orchard using three different light traps (A, B, and C type) with various lamps. The mercury lamp trap captured 125 insect species, out of which 115 were chestnut pests. The B and C type light traps, comprising a Dulux-EL white lamp, were examined for their capturing ability. The type B trap attracted Coleopteran insects (83%), while type C captured Lepidopteran insects (73%). The mercury clarity lamp along with the type B light trap was most effective in attracting Curculio sikkimensis adults (mean, 9.8 adults), while the Dulux-EL lamp captured the highest number of Dichocrocis punctiferalis adults (mean, 10.2 adults) using the type C light trap. These results suggest that selection of the appropriate types of light traps and lamps based on the target pest species is critical in ensuring effective and eco-friendly control of the pest population.

Effectiveness of Photocatalytic Techniques for Disinfection of Indoor Bioaerosols (실내 미생물 입자 살균을 위한 광촉매 기술의 효율)

  • Shin, Seoung-Ho;Kim, Mo-Geun;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.785-791
    • /
    • 2007
  • The current study evaluated the technical feasibility of the application of titanium dioxide ($TiO_{2}$) photo-catalytic air cleaners for the disinfection of bioaerosols present in indoor air. The evaluation included both laboratory and field tests and the tests of hydraulic diameter (HD) and lamp type (LT). Disinfection efficiency of photocatalytic oxidation (PCO) technique was estimated by survival ratio of bacteria or fungi calculated from the number of viable cells which form colonies on the nutrient agar plates. It was suggested that the reactor coating with $TiO_{2}$ did not enhance the adsorption of bioaerosols, and that the UV irradiation has certain extent of disinfection efficiency. The disinfection efficiency increased as HD decreased, most likely due to the decrease in the light intensity since the distance of the catalyst from the light source increased when increasing the HD. It was further suggested that the mass transfer effects were not as important as the light intensity effects on the PCO disinfection efficiency of bioaerosols. Germicidal lamp was superior to the black lamp for the disinfection of airborne bacteria and fungi, which is supported by the finding that the disinfection efficiencies were higher when the germicidal lamp was used compared to the black lamp in the laboratory test. These findings, combined with operational attributes such as a low pressure drop across the reactor and ambient temperature operation, can make the PCO reactor a possible tool in the effort to improve indoor bioaerosol levels.