• Title/Summary/Keyword: L20 method

Search Result 2,325, Processing Time 0.031 seconds

Analysis of Nursing Care Activities of Nursing Students in Clinical Experience (간호학생의 임상실습 간호활동시간 분석)

  • Lee Chung-Hee;Sung Young-Hee;Jung Yoen-Yi;Kim Jung-Suk
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.4 no.2
    • /
    • pp.249-263
    • /
    • 1998
  • The competence of newly graduated nurses is based on various clinical expriences gained when they were students. Therefore, instructors of nursing students, professors in nursing schools or directors in hospitals must play a critical role in assisting them to obtain various knowledge and experienced nursing skills. The purpose of this study was to investigate nursing care activities and nursing care hours practiced by nursing students in a general hospital. The subject students were total 214 nursing students, 2nd graders(sophomores) and 3rd graders(juniors) from 5 Junior Nursing Colleges in Seoul and they practiced at S general hospital to gain clinical experience. The data were collected for 4 days. The tools for this study were the direct nursing care activity list consisted of 15 nursing areas and the indirect nursing care activity list consisted of 9 nursing areas. The subject students were supposed to record their own score. The results of this study are ; 1. The nursing care hours per nursing student 1) The average total nursing care hours a day per each nursing student are 362.65 mins(6.04hr), the direct nursing care hours per each nursing stuent are 202.09 mins(direct nursing care rate 56.0%) and it is higher than the indirect nursing care hours, 159.75mins(indirect nursing care rate 44.0%). The direct nursing care rate of each student by a team approach in the evening shift(56.3%) is higher than that in the day shift(55.8%). 2) The hours of checking vital signs are the longest(47.35mins) among the direct nursing care activites and next is in order of counseling 8l emotional support, nurse rounds, and accompaning a patient during examination. The hours of reporting are the longest(32.39mins) among the indirect nursing care activites, and next is the activities related to education such as reviewing chart, looking up references, etc. 3) The freqency of checking vital signs practiced by nursing student is the highest(the average of 55.7 times) among the direct nursing care activities and next is in order of nurse rounds, assistance of feeding, and counseling & emotional support. The required time for nursing students to accompany their patient during examination is the longest(20.7mins) and next are in order of restriction on patient' activity, orientated by a head nurse, skin care, sitz bath, bathing & hair shampoo, and assisting with patients' exercise. 2. The nursing care hours per grader 1) The average hours of total nursing care per a nursing student are 369.2mins(6.2hrs) to 2nd graders, 355.9mins(5.9 hrs) to third graders. The direct nursing care rate per each nursing student to 3rd graders(59.3%) was higher than that to End graders(52.8%). 2) For 2nd graders, the highly marked nursing activities are teaching associated with direct nursing care activities such as drawing up papers, looking up references, reviewing charts, and being orientated by staff nurses. For 3rd graders, measurments, observations, and nurse rounds in indirect nursing care activities are taken highly 3) The most frequent practice of the nursing care activites is checking vital signs : 65 times to 3rd graders and 46.5 times to 2nd graders. Our suggestions based on the results of this study are : 1. It is recommanded to repeat the same designed study in a variety of clinical fields for further study. 2. It is recommanded to collect data not by self-record method but by observated method. 3. It is needed for nursing instructors in Nursing Schools and in hospitals to develop the guidelines and check-list of clinical practice courses.

  • PDF

A Simultaneously Analytical Method of Phthalate and Adipate Plasticizers in Food Packaging by Dual-Column GC-FID System (Dual-Column GC-FID System을 이용한 식품 포장재 중 Phthalate류 및 Adipate류 가소제의 동시 분석법)

  • Kang Gil-Jin;Kwak In-Shin;Eom Mi-Ok;Jeon Dea-Hoon;Kim Hyung-il;Sung Jun-Hyun;Choi Jung-Mi;Kim Eun-Kyung;Lee Young Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.277-283
    • /
    • 2005
  • A plasticizer is a substance which is added to a material to improve its processability, flexibility and stratchability. Phthalates and adipates are the most frequently used plasticizers of poly(vinyl chloride) (PVC). However, they can migtate into food from PVC food packaging, and some of them are especially suspected as endocrine disruptors. In this study, Simultaneous analysis of 13 phthalates and 9 adipates were carried out by dual-column gas chromatography system equipped wi two FID detectors for rapid confirmation and quantification. The Proposed method was validated with > 0.993 of linearity in the ranges of 10-500 mg/l, < $3.5\%$ RSD of reproducability in 10 inter-days sample preparations, and > $98.1\%$ of recoveries for all the plasticizers. DEHA was detected in all the 3 PVC wraps at levels of 176.9-198.5mg/g. Among the 51 samples of PVC gaskets, the targeted plasticizers were detected in 41 samples. Of these plasticizer detected samples,40 contained DIDP at the levels of 157.3-374.7 mg/g and one contained DMP at the levels of 165.6 mg/g. Also, some plasticizers were detected in other packaging materials such as PET, PP, PE, Pulp. But it might be attributed to contamination in manufacturing.

Consideration About the Bacterial Endotoxin Test Showing False Positive Test Result When Performing LAL Test (LAL Test에서 위양성을 나타내는 원인들에 대한 고찰)

  • Hwang, Ki-Young;Cho, Yong-Hyun;Lee, Yong-Suk;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.156-158
    • /
    • 2009
  • Purpose: Since radiopharmaceuticals are intended for human administration, it is imperative that we should undergo quality control very strictly. Now almost all the PET laboratories have adopted Bacterial Endotoxin Test as the stand quality control method to monitor whether pyrogen is free or not in the product vial containing crude solution. The aim of this study is to find out the reason why false positive result is observed when using commercially available test vial. Materials and Methods: For this experiment, we used commercially available single test kit (Associates of Cape Code. Inc. USA) and we made pH samples by mixing each buffer whose pH ranges are 1.0 to 12.0. Otherwise we made Ethanol samples diluted with distilled water. After making test samples, it added 0.2 mL to the test vial. Assay mixture in the test vial was incubated in a water bath (Chang Shin Co. KOR) for 60 min at $35{\pm}2^{\circ}C$. Results: After incubation period ($60{\pm}1^{\circ}C$), we inverted the test vial about $180^{\circ}$ To know what pH and how many percentage of Ethanol (Fisher Scientific Korea. Ltd) will affect the reaction. With pH buffer, false positive result was observed at pH 1.0 to 5.0 and 7.7 to 12.6 but at pH 5.2 to.7.5, the test results show negative. It's very strange that we couldn't observe negative test result with Tris buffer at pH 8.4, 8.6, 8.8, 9.0. in other case Ethanol, the test result was seen with 5 to 10% Ethanol. But to my surprise we could see very thick gel formation with 100% Ethanol. Conclusions: In this study, we could notice that pH which is too much acidic or alkalic or high concentrated Ethanol would affect Bacterial Endotoxin Test result. As you know, LAL test is sensitive and very reliable method. Therefore, we are needed to elicit the accurate test result as possible as we can.

  • PDF

Characteristics of Low Density Fiberboards Bonded with Different Adhesives for Thermal Insulation (II) - Formaldehyde·Total Volatile Organic Compounds Emission Properties and Combustion Shapes - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(II) - 폼알데하이드·총휘발성유기화합물 방출 특성 및 연소 형상 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.580-587
    • /
    • 2017
  • Woodfiber insulation board can be considered as a one of the key material for low energy consumption, comfortable and safety construction of residential space because of its eco-friendly and high thermal insulation performance. This study was carried out to investigate the formaldehyde (HCHO) total volatile organic compounds (TVOC) emission properties and combustion shapes by flame test of low density fiberboards (LDFs) prepared with different adhesives. HCHO TVOC emission and combustion properties of LDFs prepared by melamine urea formaldehyde (MUF), phenol formaldehyde (PF), emulsified methylene diphenyl diisocyanate (eMDI) and latex resin adhesives were measured by desiccator method, 20 L chamber method, and flame test, respectively. As results, LDFs manufactured by MUF, eMDI and latex resin adhesives satisfied the Super $E_0$ grade of HCHO emission performance except PF resin. Furthermore, TVOC emission of all LDFs were satisfied the Korean indoor air quality standard (below $400{\mu}g/m^2{\cdot}h$). Especially, LDF with eMDI resin adhesive showed the lowest HCHO and TVOC emissivity, that $0.14mg/{\ell}$, $12{\mu}g/m^2{\cdot}h$, respectively. However, eMDI emitted the small amount ($3{\mu}g/m^2{\cdot}h$) of toluene in VOC components. In the flame test, LDF with MUF resin adhesives showed the most favorable shape after flame test compare to LDFs prepared other adhesives. Based on HCHO and TVOC emission, and combustion shapes, MUF resin adhesive may be recommended to prepare LDF for insulation purpose.

Effect of Endothelial Cell Growth Factor and Cyclic AMP Increasers on the Proliferation of Human Omental Microvascular Endothelial Cells (사람의 대망미세혈관내피세포 증식에 대한 내피세포성장인자 및 CYCLIC AMP 증가물질의 효과)

  • Kim, Won-Gon;Kim, Jong-Man;Yu, Se-Yeong
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.463-470
    • /
    • 1995
  • Complete prelining of artificial vascular grafts with autologous endothelial cells may be one of the ideal solutions to obtain a nonthrombogenlc blood-contacting surface. To establish an intact endothelial cell monolayer on a prosthetic surface at the time of implantation,a sufficient number of endothelial cells and adequate propagation condition In cell culture are prerequisites. In this experimental study, endothelial cells from microvessels of adult human oriental adipose tissue were enzymatically harvested, and optimal culture conditions for proliferation of the endothelial cells in cell culture were examined. Human oriental adipose tissue was digested with collagenase and endothelial cells were separated from other stromal elements by mesh filtration method. Cultured cells were identified as endothelial cells by immunofluorescent staining for factor VIII-related antigen. Proliferation in usual 20% fetal bovine serum (FBS) medium or medium containing endothelial cell growth factor (ECGF)(5 ng/ml) and heparin (HEP)(1,000 units/ml) were compared,and the effects of adding compounds that increase intracellular cyclic adenosine monophosphate levels, that is,cholera toxin (CT)(1 $\mu\textrm{g}$/ml) and isobutylmethylxanthine (IBMX)(0.2 ml),were also analyzed. In total,following eight media groups were examined. 1) FBS medium + ECGF + HEP, 2) FBS medium + ECGF + HEP+CT, 3) FBS medium+ECGF+HEP+lBMX, 4) FBS medium+ECGF+HEP+CT+ IBMX, 5) FBSmedium, 6) FBS medium +CT, 7) FBS medium + IBMX, 8) FBS medium + CT + IBMX. It was shown that the medium containing ECGF + HEP with or without cholera toxin was most efficient in Stimulating cell proliferation. IBMX was considered to have antagonistic effect to ECGF. Among experimental groups without ECGF and HEP, the addition of cholera toxin and IBMX was shown to significantly potentiate cell proliferation. This results could provide a practical method for use of cultured human endothelial cells for endothelial cell seeding of cardiovascular prosthetic device, particularly in small-diameter vascular grafts.

  • PDF

A Study on the Distinct Element Modelling of Jointed Rock Masses Considering Geometrical and Mechanical Properties of Joints (절리의 기하학적 특성과 역학적 특성을 고려한 절리암반의 개별요소모델링에 관한 연구)

  • Jang, Seok-Bu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1998.05a
    • /
    • pp.35-81
    • /
    • 1998
  • Distinct Element Method(DEM) has a great advantage to model the discontinuous behaviour of jointed rock masses such as rotation, sliding, and separation of rock blocks. Geometrical data of joints by a field monitoring is not enough to model the jointed rock mass though the results of DE analysis for the jointed rock mass is most sensitive to the distributional properties of joints. Also, it is important to use a properly joint law in evaluating the stability of a jointed rock mass because the joint is considered as the contact between blocks in DEM. In this study, a stochastic modelling technique is developed and the dilatant rock joint is numerically modelled in order to consider th geometrical and mechanical properties of joints in DE analysis. The stochastic modelling technique provides a assemblage of rock blocks by reproducing the joint distribution from insufficient joint data. Numerical Modelling of joint dilatancy in a edge-edge contact of DEM enable to consider not only mechanical properties but also various boundary conditions of joint. Preprocess Procedure for a stochastic DE model is composed of a statistical process of raw data of joints, a joint generation, and a block boundary generation. This stochastic DE model is used to analyze the effect of deviations of geometrical joint parameters on .the behaviour of jointed rock masses. This modelling method may be one tool for the consistency of DE analysis because it keeps the objectivity of the numerical model. In the joint constitutive law with a dilatancy, the normal and shear behaviour of a joint are fully coupled due to dilatation. It is easy to quantify the input Parameters used in the joint law from laboratory tests. The boundary effect on the behaviour of a joint is verified from shear tests under CNL and CNS using the numerical model of a single joint. The numerical model developed is applied to jointed rock masses to evaluate the effect of joint dilation on tunnel stability.

  • PDF

Comparison of physicochemical and microorganism characteristics between the air-dried and sun-dried red pepper in south Korea (열풍 건조와 태양 건조한 국내산 고추의 물리화학적 및 미생물학적 품질 특성 비교)

  • Ku, Kyung Hyung;Lee, Kyung-A;Koo, Minseon
    • Food Science and Preservation
    • /
    • v.21 no.4
    • /
    • pp.451-459
    • /
    • 2014
  • The aim of this study was to provide useful information for making guide of quality index of Korean red pepper. The results of physicochemical characteristics analysis showed the moisture content of air-dried and sun-dried red pepper were 10.38~15.60% and 9.46~17.22%, which show that 50% of the 40 samples exceeded the 13% KS moisture standards of red pepper powder. The capsaicinoids content of the air-dried and sun-dried samples were 10.85~126.39 mg% (1,627~18,958 Scoville heat unit) and 0.43~164.09 mg% (64.5~24,613.5 Scoville heat unit). A wide distribution of ASTA values was observed: 49.12~154.69 and 70.08~182.13 for air-dried and sun-dried red pepper, respectively, with 9.29~23.10% free sugar, and 0~1,050 mg% of ascorbic acid. The total viable cells of the air-dried red peppers were 2.01~6.67 log CFU/g and of sun-dried red peppers, 1.74~5.77 log CFU/g. The contamination level of yeast in the samples were 1.03~4.12 log CFU/g of the air-dried samples and 1.05~6.10 log CFU/g of the sun-dried samples. Among the foodborne pathogens, Clostridium perfringens and Bacillus cereus were detected in many red pepper samples regardless drying method. In the principal component analysis, the first (PC1) and second principal components (PC2) accounted for 56.78 % of the total variances (38.47% and 18.31%, respectively). Ascorbic acid, ASTA, color value (L, a, b) were strongly correlated with the PC1, and quality characteristics such as moisture, microorganism, sample (drying method) showed a negative correlation with the PC1.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

Evaluation of the Fiber Separation Method and Differences in the Storage Root Fiber Content among Sweetpotato (Ipomoea batatas L.) Varieties (고구마 괴근의 섬유질 분리 조건 탐색 및 품종별 섬유질 함량 차이)

  • Won Park;Im been Lee;Mi Nam Chung;Hyeong-Un Lee;Tae Hwa Kim;Kyo Hwui Lee;Sang Sik Nam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • Fiber content in the storage roots of sweetpotato varies between different varieties. For examples, the high fiber content of certain types has a poor texture when steamed or roasted. This study was conducted to evaluate the optimal sieve mesh size for separating fibers, the chemical composition of fibers and differences in fiber content among different varieties. We found that the separated fiber content (dry weight) of mashed and steamed sweetpotato was higher after washing three times (143.3 mg/100 g) compared with that washed five times (128.4 mg/100 g). The Hogammi variety remained 85.9% of total fiber content at 10 mesh (2,000 ㎛) and 9.6% of total fiber content at 30 mesh (600 ㎛), and Jinyulmi remained 74.9 and 16.7% of total fiber content , respectively. Therefore, a 30 mesh sieve was considered the most suitable for fiber separation. Among the 10 studied cultivars, Jinhongmi showed the lowest amount of fiber (24.8 mg/100 g) and Hogammi had the highest amount (111.4 mg/100 g), which was 4.5 times larger than that of Jinhongmi. Cellulose, hemicellulose and lignin content of separated fibers showed no difference between the viscous-type Hogammi and powdery-type Jinyulmi varieties, with averages of 32.5, 22.3 and 29.6%, respectively. Correlation results using the Image J program showed a significant correlation between the distribution of the stained area and the fiber content (R = 0.74, p < 0.05). Staining distribution differed among varieties, suggesting that a simple fiber content test could be performed using the staining method on raw sweetpotato. These results provide useful information to help inform farmers on the fiber content of different sweetpotato varieties.