• Title/Summary/Keyword: L20법

Search Result 1,232, Processing Time 0.027 seconds

A Study on the Stability of Langmuir-Blodgett(LB) Films of L-${\alpha}$-Phosphatidylethanolamine Monolayer (L-${\alpha}$-Phosphatidylethanolamine 단분자층 LB막의 안정성에 관한 연구)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.44-49
    • /
    • 2014
  • We were investigated by cyclic voltammetry to the stability through the electrochemical characteristics of phospholipid(L-${\alpha}$-phosphatidylethanolamine, LAPE) monolayer LB films. LAPE monolayer LB films was deposited by the LB method on the indium tin oxide(ITO) glass. The electrochemical properties was measured by cyclic voltammetry with a three-electrode system in 0.5 N, 1.0 N, 1.5 N and 2.0 N $KClO_4$ solution. The measuring range is continuously oxidized to 1650 mV, with an initial potential of -1350 mV was reduced. Scanning rates of 50, 100, 150, 200, and 250 mV/s was set. As a result, LB monolayer films of LAPE was appeared on irreversible processes by the oxidation current from the cyclic voltammogram. Diffusion coefficient (D) of LAPE was calculated 195, 15.9, 5.75, 1.38 and $0.754cm^2s^{-1}{\times}10^{-9}$ at 0.01 N, 0.05 N, 0.10 N, 0.15 N and 0.20 N $KClO_4$ solutions, respectively.

Development of Simultaneous Analysis for Multiple Agricultural Pesticides in Raw Milk Products using GC-MS/MS (GC-MS/MS를 이용한 원유 원료 중 농약 동시분석법 확립)

  • Young Nae Choi;Yoon ho Shin;Hwangeui Cho;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.420-429
    • /
    • 2023
  • GC-MS/MS using liquid-liquid extraction (LLE) and C18 cartridges was used to identify and quantify levels of chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin and permethrin in bulk raw milk. A calibration curve spanning 10 ng/mL to 200 ng/mL was obtained with a satisfactory correlation coefficient of 0.99. The limits of detection (LOD) and limits of quantitation (LOQ) for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in the matrix ranged from 0.06 to 1.81 ng/mL and 0.19 to 6.04 ng/mL, respectively. The recoveries of 5 pesticides from spiked samples at 37.5-125 ng/mL ranged from 86.1 to 102.1%. The measurement of uncertainty of the GC-MS/MS method for these five pesticides was developed based on the analytical process and quantification. An analysis method that is easier and faster than the method specified in the Korean food standards codes for analyzing these five pesticides in raw material milk was developed. Moreover, the analytical method for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in bulk raw milk by GC-MS/MS was established.

Measurement of Nondestructive Residual Stress by Acoustoelasticity (음탄성에 의한 비파괴적 잔류응력 측정)

  • 박인근;이철구
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.25-28
    • /
    • 1999
  • 국내에 건설되어 거의 20∼30년 가동되고 있는 발전설비, 석유화학 플랜트 등 거대설비 기기의 건전성(integrity) 및 신뢰성 확보와 잔존수명 예측을 위해서는 구조물 내부 또는 표층부에 존재하는 결 함의 특성을 아는 것과 함께 그 재료의 특정 부위에 어느정도의 응력이나 변형이 있는가를 아는 것이 매우 중요하다. 일반적으로 강 용접부의 비파괴적 결함검출에는 주로 SV파(vertically shear wave)와 SH파(horizontally shear wave)라 불리는 횡파를 이용한 초음파사각탐상법이 실용화되어 이용되고 있다. 그러나 비파괴적인 방법에 의한 실험적인 잔류응력 측정, 변형해석법에는 전기 저항 및 자기 스트레인 게이지법, X선회절법, 광탄성법(photoelasticity), 모아레(Mohr's)법, 레이저스펙클(Laser speackle)법, 응 력도료법, Barkhausen Nosise법, Caustics법 등이 제시되어 있으나 그 유용성 면에서는 아직 해결되야할 문제가 많이 남아 있는 실정이다. 응력이나 변형을 해석하는 방법으로 이론적 방법, 계산적 방법 실험적 방법이 잇다. 이론적 방법에는 재료 역학적으로 취급하는 방법, 탄성론 등이 있고, 계산적인 방법에는 유한요소법이 있지만, 이론적 방법이나 계산적 방법만으로는 해석이 불가능한 경우가 많기 때문에 실험 적 방법이 필요하게 된다. 이 글에서는 파괴 시험 또는 다른 비파괴평가기술에 비해 간편한 측정, 높은 측정정도, 시험결과 도출의 신속성, 검사비용의 절감 등 많은 장점을 가지고 있고 실험적으로 유용성이 일부 검증되고 있는 음탄성법(Acoustoelasticity)에 의한 잔류응력 측정법에 관해 소개하고자 한다.TEX> mg/L(평균 49 mg/L)로 비교적 안정적인 처리효율을 보여주었다. 본 연구결과 HVC 공정은 화학약품 사용량의 절감 및 이에 따른 화학슬러지 발생량의 감소를 기대 할 수 있는 친환경기술로 유지관리비를 최소화할 수 있는 장점이 있었다. 않은 사람들 중 미래의 검진실행의지에 건강소식지가 영향을 미친 경우는 48.7%였다. 보건교육을 받은 후 유방암 자가검진 실천율은 사업군에서 53.9%로 받기 전의 27.3%보다 증가하였으나 대조군의 경우는 별 차이가 없었다. 연령별로는 60대가 가장 높았고 사업군에서 검진율의 증가분은 30대가 가장 컸다. 교육수준별로는 사업군은 고졸이, 대조군은 전문대졸이 가장 높았고 사업군에서 검진율의 증가분은 고졸에서 가장 컸다. 보건교육 후 유방암과 관련된 건강지식의 정도는 사업군이 3.7점으로 대조군보다 유의하게 높았으며, 유방암 자가검진법을 실천하는 사람들의 동기는 ‘일반 대중매체의 영향’이 가장 많았으며 건강소식지가 동기인 경우도 20.4%였다. 사업군에서 건강소식지가 유방암 자가검진법 실천에 영향을 미친 경우가 79.6%였으며 유방암 자가검진법에 관한 보건교육을 받고 실천하지 않은 사람들 중 미래의 실천의지에 건강소식지가 영향을 미친 경우는 43.6%였다. 이상의 소견에서 지역주민을 대상으로 인쇄매체를 통한 보건교육은 인쇄물만으로도 쉽게 실천 할 수 있는 유방암 자가검진법이 가장 효과적이었으며, 자궁암검진에 관해서도 검진을 받을 수 있도록 지역사회의 보건의료의 하부구조를 정비하여 제도적 장치를 마련하고 정보를 제공한다면 자궁암검진 실천율도 증가할 것이다.고 12.9% 의 발달율을 보여 유의적인 차이를 보이지 않았다. 이상의 결과로 보아 핵이식 수정란을 효율적으로 생산하기 위하여

  • PDF

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

The effect of Sowing Dates on Major Agronomic Characteristics of Dendropanax morbifera $L_{EV}$ in Southern Area of Korea (남부 도서지역에서 황칠나무의 파종기에 따른 주요 형질변이)

  • 최성규;윤경원
    • Korean Journal of Plant Resources
    • /
    • v.14 no.1
    • /
    • pp.60-64
    • /
    • 2001
  • This study was carried out to investigate effects of sowing dates and method on major agronomic characteristics of Dendropanax morbifera $L_{EV}$. in southern area of Korea. The number of days from sowing to emergence was recognized liner negative correlation between sowing days. Dendropanax morbifera was sowed at seven different dates(from Dec.20 to Feb.20 at 30 days interval, from Mar, 1 to Apr. 15 at 15 days interval) in pot culture. In sowing date at Mar. 15, germination rate and early growth were good in pot. Dendropanax morbifera was sowed at five different dates(from Dec.20 to Apr.15 at 15 days interval) in field culture. In sowing date at Apr.15, germination rate and early growth were good in field culture.

  • PDF

Effects of PNF Stretching on Balance During Single-Leg Standing in Older Adults (PNF 스트레칭이 노인의 한발서기 균형에 미치는 영향)

  • Park, Jung-Seo
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.351-358
    • /
    • 2022
  • Purpose: This study aims to determine the correlation between the effects of contract-relax-antagonist-contract (CRAC) and contract-relax (CR) forms of proprioceptive neuromuscular facilitation (PNF) stretching on balance during single-leg standing in elderly people. Methods: The participants were 20 elderly people in healthy condition and divided equally into two groups: the CRAC stretching group and the CR stretching group. Subjects were made to walk on a treadmill for 6 minutes before the stretching as a warm-up. CR and CRAC stretching were performed on the soleus. The dependent variables used to assess single-leg standing balance were overall stability(OSI), anterior/posterior(A/P) movement, and medial/lateral(M/L) movement. The statistical methods used to assess the differences between groups were verified using the Mann-Whitney U test and the Wilcoxon signed-rank test. Results: The CRAC group had significantly increased OSI, A/P and M/L after the PNF stretching intervention (p < 0.05). The CR group had significantly increased OSI and A/P after the PNF stretching intervention (p < 0.05), but M/L did not significantly increase (p > 0.05). There was no significant difference in stretching between CRAC and CR (p > 0.05). Conclusion: The results of this study revealed that CR and CRAC PNF stretching improved single-leg standing balance. CARC stretching before exercise is helpful for elderly people, as it improves balance.

Distributions of Nicotine and Toluene in Teenagers' Urine (청소년의 뇨 중에서 nicotine과 톨루엔의 분포에 관한 연구)

  • Park, Sungwoo;Seo, Baeseck;You, Jaehoon;Kim, Namyee;Shin, Hosang;Han, Wansoo;Kim, Ilkwang
    • Analytical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • We identified nicotine, cotinine and toluene in high school volunteer's urine by using GC/NPD, GC/FID and GC/MS. To analyze of nicotine and cotinine, urine samples were extracted with diethylether and centrifuged on a benchtop centrifuge for 5 min. The upper organic layer was injected into a GC. The distributions of nicotine and cotinine were $4{\sim}630{\mu}g/L$ and $63{\sim}1,602{\mu}g/L$ in smoking-group, respectively. To analyze of toluene, head space vial was filled with 2mL sodium citrate solution and 1mL of urine. The vial was warmed in a water bath at $55^{\circ}C$ for 20min, and then $250{\mu}L$ of head space air was injected into a GC. The result show that toluene was not detected in all of the volunteers' samples. However, the range of toluene was 0.1~28.0mg/L in glue sniffer's urine samples(NISI data).

  • PDF

The Comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$ Method (방사선 선량의 표준 측정법(한국의학물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법의 비교)

  • Yi, Byong-Yong;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.337-342
    • /
    • 1991
  • The comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$(ICRU-21 and SCRAD protocol) method is studied. The therapetutic range of radiation (photon 4MV-l5MV and electron 6 MeV-20MeV) and three kinds of the chambers were used in the water phantom. The results from 7G-21 and KAPM protocol did not show much differences (less than 1$\%$) throughout the whole energy range; $N_D$ from KAPM protocol and Ngas from TG-21 showed 0.2$\%$ deviation mainly from W/e difference between two protocols. But the results from KAPM protocol (1990) and those from $C_{\lambda}/C_E$ Method showed $-1.9{\pm}0.6\%$ (KAPM protocol is higher) deviation for photom beam and $+3.3{\pm}1\%$ (KAPM protocol is lower) deviation for electron beams.

  • PDF

Studies on the Pulp Bleaching for Reducing AOX(I) - The Pulp Bleaching Method Using A and $D_{(H/L)}$ Treatment - (AOX 감소를 위한 새로운 표백법 (제1보) - A처리 및 $D_{(H/L)}$ 처리를 이용한 표백법 -)

  • 윤병호;김기선;이선호
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 1997
  • This study was aimed to decrease AOX(Adsorbed Organic Halide Compounds) by applying bleaching methods of A(HNO$_3$ + NaNO$_2$) and $D^{(H/L)}$(dual pH chlorine dioxide bleaching) to conventional OCEDED bleaching stages. And so we investigate the effects of NSA treatment and the influence of production rate of ion species in chlorine dioxide and pulp mixtures according to various pH as well as dual pH on pulp bleaching. Finally the effects of AOC_DED^{(H/L)}ED^{(H/L)}$ bleaching stage were investigated by measuring AOX, brightness, kappa number and viscosity of pulps. A stage was treated by using 4% $HNO_3$ and 0.05~2.0% $NaNO_2$ on pulp and $D^{(H/L)}$ stage was like that pulp mixed with chlorine dioxide solution was adjusted at pH 7.0 and reacted in pulp cosistency 3%, S~20min, $70^{\circ}C$, and then successively for 160~175min at pH 4.0. It was found that suitable $NaNO_2$ addition rate was at 0.6% where the brigtness of pulp was most higher and pulp viscosity was not decreased much. Chlorate ($CIO_3$) was decreased according to pH increase but chlorite($CIO_2$) was highly decreased according to pH increase. And chloride was slightly increased with pH increase. The applying of A and D^{(H/L)}$ bleaching stages to some various multiple bleaching stages ($AOC_DED^{(H/L)}/EopD^{(H/L)} etc.$) had good results that brightness was increased more 2~3% ISO than conventional method(OCEDEopD), but viscosity was dropped by only 1~2cps.

  • PDF

Determination of terbutaline in human plasma by coupled column chromatography (커플드칼럼크로마토그래피에 의한 사람 혈장 중 테르부탈린의 정량)

  • Ko, Mi Young;Jeon, Sang-Seol;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • A method was developed and fully validated for the determination of terbutaline, a β2-receptor agonist, in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak silica, followed by high-performance liquid chromatography (HPLC). The terbutaline was pre-separated from the interfering components in plasma on a Luna C18 (2) column, and terbutaline and salbutamol as an internal standard were resolved and determined on a Luna Silica column. The two columns were connected by a switching valve equipped with silica pre-column. The pre-column was used to concentrate the terbutaline in the eluent from the C18 column before back-flushing onto the silica column with fluorescence detection at an excitation/emission wavelength of 276/306 nm. The method was shown to be specific by testing six different human plasma sources. Linearity was established for a concentration range of 0.4-20.0 ng/mL with a correlation coefficient of 0.9999. The lower limit of quantitation was 0.4 ng/mL with a precision of 10.1% as C.V.%.