• 제목/요약/키워드: L1 Korean

검색결과 46,774건 처리시간 0.077초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

자기폭풍 기간 중 정지궤도 공간에서의 입자 유입률과 Dst 지수 사이의 상관관계 (THE RELATIONSHIP BETWEEN PARTICLE INJECTION RATE OBSERVED AT GEOSYNCHRONOUS ORBIT AND DST INDEX DURING GEOMAGNETIC STORMS)

  • 문가희;안병호
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권2호
    • /
    • pp.109-122
    • /
    • 2003
  • 자기폭풍(magnetic storm)과 서브스톰(substorm)의 인과관계를 규명하기 위하여 서브스톰 확장기 활동(substorm expansive activity)의 전형적인 지시자로 알려진 정지궤도 위성에서 관측된 양성자 플럭스(proton flux)의 무분산 입자유입률(dispersionless particle injection rate)과 Dst 지수와의 상관관계를 조사하였다. 본 연구에 이용된 자기폭풍은 1996년에서 2000년까지 5년 동안에 일어난 것으로 자기폭풍 기간 중 Dst의 최소값인 $Dst_{min}$의 크기에 따라 대규모($-200nT{$\leq$}Dst_{min}{$\leq$}-100nT$), 중규모($-100nT{\leq}Dst_{min}{\leq}-50nT$), 소규모 자기폭풍($-50nT{\leq}Dst_{min}{\leq}-30nT$)의 3단계로 구분하였다. 양성자 플럭스는 LANL의 정지궤도 위성에서 관측된 자료 중에서 주로 환전류(ring current)를 구성하는 입자의 에너지에 해당하는 50keV에서 670keV 범위의 6개 에너지 채널의 자료를 이용하였다. 그리고 입자유입은 자정 부근에서 주로 일어나므로 18:00~04:00MLT구간에서 관측된 자료만을 이용하였다. 한편 내부 자기권으로 유입되는 입자에너지를 추정하기 위하여 양성자 플럭스 비($f_{max}/f_{ave}$)를 조사하였다. 여기서, $f_{ave}$$f_{max}$는 각각 입자유입이 일어나기 전 후의 양성자 플럭스의 양을 나타낸다. 한편 자기폭풍 기간 동안에 1 ~ 2개의 인공위성 관측으로부터 내부 자기권으로 유입되는 총 에너지량을 추정하는 것이 불가능하다는 것이 알려졌다. 그러나 총 에너지 유입량은 적어도 플럭스 비와 유입횟수에 비례할 것이다. 따라서 내부 자기권으로 유입되는 에너지의 양을 간접적으로 추정하기 위해서 이들의 곱으로 정의되는 총 에너지 유입률 지수(total energy injection parameter, TEIP)를 제안하였다. 특히 서브스톰이 자기폭풍의 발달에 기여하는 정도를 알기 위하여 자기폭풍을 두 구간, 즉 주상(main phase)과 회복기(recovery phase)로 나누어 조사하였다. 양성자의 무분산 유입자료와 자기폭풍 기간 중 Dst$_{min}$ 값을 비교해 본 결과 다음과 같은 특성이 확인되었다. 첫째, 주상기간 중 입자들의 평균 유입횟수는 자기폭풍의 크기에 비례하여 증가하는 경향을 나타내며 유입휫수와 $Dst_{min}$ 사이에는 높은 상관관계(0.83)가 있었다. 둘째, 주상기간 중 자기폭풍의 크기가 클수록 플럭스 비 ($f_{max}/f_{ave}$는 대체로 증가하는 경향을 나타냈다. 그리고 75~113keV 에너지 채널에서의 $Dst_{min}$ 값과 플럭스 비의 상관계수는 0.74로서 가장 높았으며 나머지 에너지 채널 역시 비교적 높은 상관관계를 나타냈다. 셋째, 주상기간 중 총 에너지 유입률 지수와 $Dst_{min}$ 사이에 높은 상관관계가 확인되었다. 특히 환전류를 구성하는 주요 입자의 에너지 영역(75~l13keV)에서 가장 높은(0.80) 상관계수를 기록했다. 넷째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.

기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성 (The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation)

  • 나주옥;임채만;심태선;박주헌;이기만;아상도;김우성;김동순;김원동;고윤석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권3호
    • /
    • pp.350-362
    • /
    • 1999
  • 연구배경: 침습적 기계 호흡 이탈에 성공하여 기관내 관을 제거하였으나 48시간 이내에 급성 호흡 부전이 경우 또는 환자 스스로 기관내 관을 제거한 후 발생된 급성 호흡 부전은 이탈 실패의 중요한 원인이며, 발생시 기관내 관의 재삽관을 통한 호흡 보조가 표준적 치료이다. 비침습적 양압 환기법(noninvasive positive pressure ventilation이하 NIPPV)은 비 혹은 안면마스크를 통해 양압 환기를 시행하므로 기관내 삽관을 회피할 수 있다. 본 연구는 기계 호흡 이탈 후 기관내 관을 제거한 환자들에게 발생된 급성 호흡 부전 시 NIPPV 적용이 기관내 삽관을 통한 양압 환기 치료를 대체할 수 있는지를 알아보고자 하였다. 방 법: 대상은 아산 재단 서울 중앙병원 내과계 중환자실에 입원하여 기계적 환기 치료를 받고 이탈 과정에서 기관내 관 제거 후 48시간 이내에 급성 호흡 부전이 발생한 환자 21명 및 스스로 기관내 관을 제거한 후 급성 호흡 부전이 발생한 환자 7명과 기관내 관이 기도내 분비물로 막혀 기관내 관을 제거한 환자 2명등 총 31명에게 NIPPV를 적용하였다. NIPPV는 환자 상태에 따라 기계 환기 양식, 압력 보조 수준 및 흡입 산소의 양이 조절 되어졌으며, 압력 보조 8cm $H_2O$미만에서 임상적으로 안정된 상태를 유지하는 경우 완전히 NIPPV에서 이탈하였다. 성공군은 NIPPV 이탈후 48 시간 이상 자발 호흡을 유지한 경우로 정의하였고, 실패군은 NIPPV 시행 후 호흡 부전 소견이나 동맥혈 가스검사의 호전이 없어 다시 기관내 삽관을 시행하여 기계호흡을 시행한 환자로 정의하였다. 각 군에서 NIPPV적용 직전, 적용 후 30분, 6시간, 24시간, NIPPV 이탈 작전 또는 실패하여 기관내 재삽관으로 전환 직전의 심박동수, 분당 호흡수, 동맥혈 가스검사, 압력 보조 수준 및 호기말 양압등을 비교하였다. 결 과: 총 31명에서 NIPPV를 적용하였고, 이 중 성공군은 14명(45%)이었다. 성공군과 실패군을 비교 시 나이, 중환자실 입원 당시의 APACHE III 점수, 기관 내 삽관 기간, 기관내 관 제거 후 NIPPV적용시까지의 시간 및 NIPPV 시행 직전의 분당 호흡수, 심박동수, 동맥혈 가스검사, $PaO_2/FiO_2$ 등은 양군간에 유의한 차이가 없었다. 모든 환자에서 NIPPV적용 30분후부터 분당 호흡수 및 심박동수는 감소하였고 동맥혈 산소 포화도는 증가하였다.(p<0.05) 그러나, 실패군에서는 NIPPV 시행중에 상태가 악화되어 기관내 재삽관을 시행하였고, 재삽관 작전의 분당 호흡수 및 심박동수는 다시 증가하였으며 동맥혈 산소포화도는 감소하였다(p<0.05). 기저 질환이 COPD 이면서 기관내 관 제거 후 급성 호흡부전이 발생한 환자 8명에게 NIPPV 적용 시 COPD가 아닌 다른 환자들에 비해 NIPPV의 성공률이 의미 있게 높았다(62% 대 39%)(p=0.007). NIPPV를 이용한 이탈 시 실패의 원인으로는 기저 질환의 악화 없이 동맥혈 가스 소견이 악화되었던 예가 9예, 그 외 기저 질환 악화 5예, 마스크 부적응이 2예, 기도내 분비물 축적이 1예였다. 결 론: NIPPV는 침습적 기계 호흡이탈과정에서 특히 기저질환이 COPD인 환자들의 경우 기관내 관 제거 후 발생한 급성 호흡 부전 시 기관내 관의 재삽관을 피할 수 있는 유용한 치료적인 방법으로 사료된다.

  • PDF

포장재배(圃場栽培) 수도(水稻)의 무기영양(無機營養) -[I] 삼요소이용률(三要素利用率)과 양분흡수량(養分吸收量), 수량(收量) 및 건물생산량(乾物生産量)과(乾物生産量)의 관계(關係)- (Mineral Nutrition of the Field-Grown Rice Plant -[I] Recovery of Fertilizer Nitrogen, Phosphorus and Potassium in Relation to Nutrient Uptake, Grain and Dry Matter Yield-)

  • 박훈
    • Applied Biological Chemistry
    • /
    • 제16권2호
    • /
    • pp.99-111
    • /
    • 1973
  • 전국적(全國的)으로 실시한 삼요소(三要素) 시험중(試驗中) 1967년(年) 51개소(個所) 68년(年)에 32개소(個所)에서 N 8, 10, 12, 14kg/10a 수준(水準)과 $P_2O_5$$K_2O$ 각(各) 6과 8kg 시비수준(施肥水準)에 대(對)한 삼요소(三要素) 이용율(利用率)을 조사(調査)하였다. 삼요소(三要素) 이용율(利用率)과 수량(收量) 및 건물생산량(乾物生産量), 삼요소(三要素) 및 규산흡수량(珪酸吸收量)과의 아래와 같은 관계에서 무기양분(無機養分)의 생산(生産)에 기여하는 양상(樣相)이 시용(施用)한 P가 1차적(次的)으로 Si흡수(吸收)를 이차적(二次的)으로 Si가 N흡수(吸收)를 조장(助長)하여 기여하는 P형(型)과 시용(施用)한 K가 P흡수(吸收)를, 이차적(二次的)으로 P가 N흡수(吸收)를 조장(助長)하여 기여하는 K형(型)으로 연도별(年度別) 주도형(主導型)을 구분(區分)할 수 있었다. 1. 질소(窒素)는 전포장수(全圃場數)의 4%, 인산(燐酸)은 48%, 가리(加里)는 38%가 0 또는 부(負)의 이용율(利用率)을 보였으며 이용율(利用率)의 발현빈도(發現頻度) 백분분포(百分分布)가 N는 30 내지 40에서 최고빈도(最高頻度)를 보이는 정규분포(正規分布)에 가깝게, P와 K는 0 이하(以下)에서 최고빈도(最高頻度)를 갖고 점차 감소하는 편의 분포(分布)를 갖는다. 2. 삼요소(三要素) 이용율(利用率) (0 이상(以上)만)은 67년(年)에 N는 33(10kg 시비(施肥) 수준이상(水準以上)) P는 27, K는 40이고 68년(年)엔 40, 20, 46%이고 부(負)의 이용율(利用率)을 0으로한 2개년(個年) 평균(平均)은33(8kg 이상(以上)) 13, 27이었다. 3. 이용율(利用率)의 표준편차(漂準偏差)는 P와 K에서 이용율(利用率)보다 크고 P이용율(利用率)의 변이(變異)가 가장 크다. 4. 이용율(利用率)과 수량(收量) 또는 건물생산량(乾物生産量)과의 유의상관(有意相關) 출현빈도(出現頻度)는 N>K>P의 순(順)이며 10kg 수준의 N이용율(利用率)은 67년(年)엔 P이용율(利用率)과만 63년(年)엔 K이용율(利用率)과만 유의상관(有意相關)을 갖는다. 5. P이용율(利用率)은 그것이 높고 K이용율(利用率)이 낮았던 67년(年)에만, 그리고 K이용율(利用率)은 그와 반대였던 68년(年)에만 모든 처리구의 건물생산량(乾物生産量)과 유의상관(有意相關)을 보이고, 유의상관(有意相關)이 없는 해에는 무비구(無肥區) 및 결비구(缺肥區)區에서 부상관계수(負相顯係數)를 보이고 있다. 6. 이용율(利用率)과 수량(收量)과의 상관(相關)은 이용율(利用率)과 건물생산량(乾物生産量)과의 상관(相關)과 경향은 유사하나 유의성이 적어삼요소(三要素) 영양(營養)은 건물생산(乾物生産)에서 잘 표현된다. 7. N이용율(利用率)은 N시비구(施肥區)의 N흡수량(吸收量)과 많은 경우 유의상관(有意相關)을, 무(無)N구(區)의 흡수량(吸收量)과는 유의부상관(有意負相關)을 보이며, N시비구(施肥區)의 P, K또는 Si흡수량(吸收量)과도 여러 경우 유의상관(有意相關)을 보였다. 8. P이용율(利用率)은 그것이 높았던 67년(年)만 모든 처리구에서 Si흡수량(吸收量)과, 그리고 무(無)P구(區)를 제(除)한 모든 처리구의 N 흡수량(吸收量)과 유의상관(有意相關)을 보여 P는 일차적(一次的)으로 Si흡수(吸收)를 돕고 이차적(二次的)으로 Si흡수(吸收)가 N흡수(吸收)를 조장(助長)함을 나타낸다. P이용율(利用率)은 N시비구(施肥區)의 P흡수량(吸收量)과 K흡수량(吸收量)과도 많은 경우 유의상관(有意相關)을 보였다. 9. K이용율(利用率)은 그것이 컸던 68년(年)에 모든 처리구의 P흡수량(吸收量)과 무(無)N구(區)을 제(除)한 모든 처리구의 N흡수량(吸收量)과 그리고 무(無)P구(區)를 제(除)한 모든 처리구의 K흡수량(吸收量)과 유의상관(有意相關)을 보이며 무(無)K구(區)의 K흡수량(吸收量)과는 부상관(負相關)이고 K이용율(利用率)이 적었던 67년(年)에는 무비구(無肥區)나 결비구(缺肥區)의 P흡수량(吸收量)과 유의성(有意性)은 없으나 부상관(負相關)이었다. K이용율(利用率)은 N나 P와는 달리 K흡수량(吸收量)과 보다 수량(收量)이나 건물생산량(乾物生産量)과의 상관(相關)이 더 크며 K이용율(利用率)이 컸던 해에만 Si흡수량(吸收量)과 무(無)N구(區)와 최고시비구(最高施肥區)에서 유의상관(有意相關)을 갖고 무(無)K구(區)에서 유의부상관(有意負相關)을 보였다. 이로서 K는 일차적(一次的)으로 P흡수(吸收)를 돕고 이차적(二次的)으로 P가 N흡수(吸收)를 도와서 생산(生産)에 기여하는 것 같다. 10. N이용율(利用率)과 수량(收量)이나 건물생산량(乾物生産量)과의 상관(相關)이 무(無)P구(區)에서 보다 무(無)K구(區)가 높고 무(無)K구(區)보다 시비구(施肥區)에서 높으며 이러한 경향은 N이용율(利用率)과 N흡수량(吸收量)사이에서도 동일(同一)하였다. 이 사실과, K이용율(利用率)과 건물생산량(乾物生産量)과의 관계는 P가 N흡수(吸收)를 돕고 N나 P가 부족(不足)할 때에는 K가 N흡수(吸收)를 경쟁적으로 억제하여 생산(生産)을 저하(低下)시키는 것을 나타낸다. 11. 삼요소(三要素) 이용율(利用率)은 67년(年)에는 무(無)P구(區)의 상대건물생산량(相對乾物生産量)과, 68년(年)에는 무(無)K구(區)의 상대수량(相對收量)과 유의상관(有意相關)을 갖는다. 이는 P가 분얼 즉 영양생장단계에, K가 곡실형성 즉 생식 생장단계에 더 작용(作用)하였음을 나타내고 있다. 12. 삼요소(三要素) 이용율(利用率)과 결비구(缺肥區)의 상대생산량(相對生産量)이나 무비구(無肥區)의 결비구(缺肥區)에 대(對)한 상대생산량(相對生産量)과의 상관(相關)에서 어느 경우에도 N가 수도생산(水稻生産)에 가장 큰 역할(役割)을 하고 있음을 보였다. 13. 이상의 결과에서 40 내지 50%의 포장(圃場)은 P와 K를 시비(施肥)하지 아니해도 되며 시비량(施肥量)도 연도(年度)및 포장에 따라 변이(變異)가 커야 할 것이며 특히 P에서 그러하다.

  • PDF