L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성 (Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT)

  • 고현수;박순기;김은혜;최종숙;정우영;이동윤
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가 (Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations)

  • 김지현;박훈희;이주영;남궁식;손현수;박상륜
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.49-61
    • /
    • 2014
  • 인구의 고령화와 함께 골다공증성 척추압박골절 환자의 발병률은 매년 증가하는 추세이며 경피적 척추성형(percutaneous vertebroplasty, PVP)은 가장 많이 시행되는 표준화된 치료 방법이다. 시술 전 후의 정확한 진단평가에 있어 SPECT/CT 검사의 유용성이 우수하다는 연구 보고가 있으나 시술에 사용되는 골 시멘트(bone cement) 물질은 CT 영상에서 인공물(artifact)을 생성하여 영상품질에 영향을 미친다. 이에 본 연구에서는 골 시멘트가 SPECT/CT 영상에 미치는 영향을 평가하는 데 목적을 두었다. NEMA-1994 팬텀(phantom)에 배후방사능(3.6 kBq/ml), 열소(29.6 kBq/ml), 냉소(물)를 설정한 후 각 원통(cylinder)에 모형 시멘트를 삽입하여 영상 획득하였다. Astonish (Iterative: 4, Subset: 16)으로 재구성하였고, CT 보정 방법은 비감쇠보정(NAC), 감쇠보정(AC+SC-), 감쇠 및 산란보정(AC+SC+) 3가지 방법을 사용하였다. 각각의 보정방법에 따른 평균계수와 시멘트물질의 유 무에 따른 계수 변화율을 비교하고 대조도 회복 계수(contrast recovery coefficient, CRC)를 구했다. 또한, 압박골절 진단을 받은 환자 107명 중 PVP를 시행한 20명을 선별하여 추체를 골절, 정상, 시멘트로 나누고 연조직(척추기립근)을 포함 4곳의 평균 계수를 측정한 후, 뼈/연조직 간 계수 비(bone/soft tissue ratio, B/S ratio)을 구했다. NAC를 기준으로 AC+SC-, AC+SC+의 평균계수는 증가하였고, AC+SC-의 평균계수가 가장 높았으며, AC+SC+는 AC+SC-에 비해 상대적으로 낮았다. 시멘트 물질의 유 무에 따른 평균계수는 시멘트가 존재할 때 NAC, AC+SC-, AC+SC+에 따라 팬텀의 열소에서 12.4%, 6.5%, 1.5%, 냉소 75.2%, 85.4%, 102.9%, 배후방사능 13.6%, 18.2%, 9.1%, 임상영상의 골절부에서 33.1%, 41.4%, 63.5%, 정상부 53.1%, 61.6%, 67.7%, 연조직 10.0%, 4.7%, 3.6%의 증가율을 보였다. 반면 원통 내부의 시멘트 인접부에서 상대적 계수감소를 확인할 수 있었고, 병소에 대한 팬텀영상과 임상영상간의 계수 증가율은 상반된 양상을 보였다. 대조도 비를 나타내는 CRC와 B/S ratio는 NAC, AC+SC-, AC+SC+순으로 향상되었고, 팬텀의 냉소에서는 큰 변화 없이 일정하였다. 정량적 계수는 AC+SC-가, 대조도 비는 AC+SC+가 가장 높게 분석되었다. PVP 시행 환자의 척추 뼈 SPECT/CT 검사에서 AC+SC- 의 사용은 영상계수를 대폭 향상시켜 특히 병소의 농도가 높은 영상을 얻는 반면에 골 시멘트의 영향과 함께, 연부조직 및 산란영역의 영상잡음 계수까지 증가시키므로 대조도비를 향상시키는 AC+SC+의 적용을 병행한다면 임상진단에 유용할 것으로 사료된다.

  • PDF