• Title/Summary/Keyword: L-Tube

Search Result 796, Processing Time 0.025 seconds

Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation (화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법)

  • Kim, Bum-Shin;Song, Gee-Wook;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.563-569
    • /
    • 2012
  • The superheater and reheater tubes of a heavy-load fossil power plant boiler can be damaged by overheating, and therefore, the degree of overheating is assessed by measuring the oxide scale thickness inside the tube during outages. The tube temperature prediction from the oxide scale thickness measurement is necessarily accompanied by destructive tube sampling, and the result of tube temperature prediction cannot be expected to be accurate unless the selection of the overheated point is precise and the initial-operation tube temperature has been obtained. In contrast, if the tube temperature is to be predicted analytically, considerable effort (to carry out the analysis of combustion, radiation, convection heat transfer, and turbulence fluid dynamics of the gas outside the tube) is required. In addition, in the case of analytical tube temperature prediction, load changes, variations in the fuel composition, and operation mode changes are hardly considered, thus impeding the continuous monitoring of the tube temperature. This paper proposes a method for the short-term prediction of tube temperature; the method involves the use of boiler operation information and flow-network-analysis-based tube heat flux. This method can help in high-temperaturedamage monitoring when it is integrated with a practical tube-damage-assessment method such as the Larson-Miller Parameter.

Effects of Pitch on Pool Boiling from Horizontal Tube Array (피치가 수평 튜브 배열의 풀비등에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.719-726
    • /
    • 2017
  • An experimental study was performed to investigate the combined effects of the pitch and heat flux of nearby tubes on boiling in a pool as well as the heat transfer from a horizontally-installed tube bundle. For this test, two smooth stainless steel tubes (19 mm outside diameter) were used, and the water was at atmospheric pressure. The pitch of these tubes was varied between 28.5 mm and 95 mm, and the heat flux of the nearby tube altered between 0 and $90kW/m^2$. Enhancements in heat transfer were clearly observed when the heat flux of the nearby tube increased while the heat flux of the test section remained below $40kW/m^2$. The tube pitch was found to have a negligible effect on heat transfer when the pitch was greater than four times larger than the tube diameter. The circulating flow, convective flow, and liquid agitation were all seen to enhance heat transfer; however, the interaction between the flow and coalescence of bubbles was detrimental to heat transfer.

Measurement of Average Pool Boiling Heat Transfer Coefficient on Near-Horizontal Tube (수평 가까운 튜브 표면의 평균 풀비등 열전달계수의 측정)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • An experimental study is performed to obtain an average heat transfer coefficient around the perimeter of a near horizontal tube. For the test a stainless steel tube of 50.8 mm diameter submerged in water at atmospheric pressure is used. Both subcooled and saturated pool boiling conditions are considered and the inclination angle of the tube is changed from the horizontal position to $9^{\circ}$ in steps of $3^{\circ}$. In saturated water, the local boiling heat transfer coefficient at the azimuthal angle of $90^{\circ}$ from the tube bottom can be regarded as the average of the coefficients regardless of the tube inclination angles. However, when the water is subcooled the location for the average heat transfer coefficient depends on the inclination angle and the heat flux. It is explained that the major mechanisms changing the heat transfer are closely related with the intensity of the liquid agitation and the generation of big size bubbles through bubble coalescence.

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

Comparative Analysis between Early Minithoracotomy and Conventional Treatment for Empyema (농흉치료에 대한 조기 Minithoracotomy 와 흉관삽관술의 비교연구)

  • 임종수
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1101-1105
    • /
    • 1989
  • Fifty one patients with empyema thoracic were managed at the Kyung Hee University Medical Center during 5 years between December, 1982, and December, 1987. The patients were classified into two groups; group A [early minithoracotomy-9 patients] and group B[conventional chest tube insertion-42 patients]. Each group was retrospectively analyzed to compare the results in terms of leukocyte count change, body temperature change, duration of hospitalization, elapsed time to chest tube removal and the need for subsequent decortication and tube change. There was no statistical difference between two groups in terms of etiology, age and sex. l. In the group A, mean preoperative leukocyte count [19,300/mme] decreased to 8,688/mme postoperatively. In the group B, leukocyte count changed from 16,985/mme to 14,433/mme. Their differences were significant [P< 0.05]. 2. In the group A, mean preoperative body temperature [38.5] decreased to 36.7. In the group B, body temperature changed from 38.1oC to 37.5 oC. Their differences were significant [P < 0.05]. 3. Mean duration of Hospitalization; 18.2 days [group A], 30.2 days [group B]. Their differences were significant [P < 0.01]. 4. Mean elapsing time for chest tube removal; 15.2 days [group A], 28.5 days [group B]. Their differences were significant [P < 0.01]. 5. There was no need for subsequent decortication and chest tube change in the group A. There were 22 cases [52.3 %] for subsequent decortication and 12 cases [28.6 %] for chest tube change in the group B. Early minithoracotomy in treating empyema thoracis resulted in a shorter hospital stay and a shorter period of tube drainage than conventional method.

  • PDF

Transverse Low Velocity Impact Failure Behavior of Triaxial Braided Composite Tube with Different Braiding Angles (Triaxial braiding 기술을 이용한 원형 튜브의 횡방향 저속충격파괴 거동분석)

  • Sim, Ji-hyun;Park, Sung-min;Kim, Ji-hye;Shin, Dong-woo;Chon, Jin-sung;Kim, Jae-kwan;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.28 no.4
    • /
    • pp.246-252
    • /
    • 2016
  • In comparison to metal alloys, braided composite features a high impact resistance and crash energy absorption potential, and also it still remained competitive stiffness and strength properties. Braiding angle is one of the most important parameters which affect the mechanical behaviors of braided composite. This paper presents transverse low velocity impact failure behavior analysis on the carbon 3D triaxial braided composite tube with the braiding angle of $20^{\circ}$, $50^{\circ}$ and $80^{\circ}$. The flexural behaviour of 3D triaxial braided composite tube under bending loads was studied by conducting quasistatic three point bending test. Also, the low velocity impact responses of the braided composite tubes were also tested to obtain load-displacement curves and energy absorption. Consequently, the increase of the braided angle, the peak load also increases owing to the bigger bending stiffness.

Study on Thermal Efficiency according to Configuration Change and Contact Resistance of Solar Collector with Single Evacuated Tube-type (단일진공관 태양열집열기의 형상변화 및 접촉저항에 따른 집열효율 연구)

  • Choi, Bo-Won;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of its infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to investigate the efficiency of heat collection using solar collector with single evacuated tube-type. As the results, the temperature of radiation fin for solar collector with single evacuated tube-type was lower in spite of high temperature of heat pipe compared that of double evacuated tube-type. In order to increase the efficiency of heat collection, it was confirmed that the loss of heat collection due to contact resistance as well as performance improvement for solar collector should be decreased.

An experimental study on the thermal entrance lengths for viscoelastic polymer solutions in turbulent tube flow (점탄성 특성을 가진 폴리머용액의 난류유동 열적입구길이에 관한 실험적 연구)

  • 유상신;황태성;엄정섭
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1189-1196
    • /
    • 1988
  • Thermal entrance lengths of turbulent tube flow for viscoelastic polymer solutions are investigated experimentally in the recirculating flow system with tubes of inside diameters 8.5mm(L/D=710) and 10.3mm(L/D=1158), respectively. In the present system, the hydrodynamic and thermal boundary layers develop simultaneously from the beginning of the test section. To provide the boundary condition of constant heat flux at the wall, the test tubes are heated directly by electricity. The polymer solution used in the current study is 1000 wppm aqueous solution of polyacrylamide(Separan AP-273). The apparent viscosity of the polymer solutions circulating in the flow system are measured by the capillary tube viscometer at regular time intervals. Thermal entrance lengths vary due to the rate of degradation. The entrance lengths of degraded polymer solutions are about 500~600 times the diameter. However, the entrance lengths of fresh polymer solutions are greater than the lengths of the test tubes used in this study suggesting that thermal entrance lengths for viscoelastic polymer solutions are greater than 1100 tube times the diameters. Friction factor is almost insensitive to the degradation, but the heat transfer $j_{H}$-factor is affected seriously by degradation. Based on the present experimental data of fresh solutions a correlation for the heat transfer $j_{H}$-factor is presented.ted.