• Title/Summary/Keyword: L-Tube

Search Result 796, Processing Time 0.019 seconds

A Technique for Defect Detection of Condenser Tube in Support Plate Region using Guided Wave (유도초음파를 이용한 복수기 튜브지지판 영역에서의 결함검출기법)

  • Kim, Yong-Kwon;Park, Ik-Keun;Park, Sae-Jun;Ahn, Yeon-Shik;Gil, Doo-Song
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.36-41
    • /
    • 2012
  • General condensers consist of many tubes supported by tube sheets and support plates to prevent the deflection of the condenser tubes. When a fluid at high pressure and temperature runs over the tubes for the purpose of transferring heat from one medium to another, the tubes vibrate and their surface comes into contact with the support plates. This vibration causes damage to the tubes, such as cracks and wear. We propose an ultrasonic guided wave technique to detect the above problems in the support plate region. In the proposed method, the ultrasonic guided wave mode, L(0,1), is excited using an internal transducer probe from a single position at the end of the tube. In this paper, we present a preliminary experimental verification using a super stainless tube and show that the defects can be discriminated from the support signals in the support region.

CFD Analysis for the Design of a Venturi Tube-type Air Bubble Generator with Porous Material Throat (다공성 재질의 목을 가진 벤츄리 관 공기방울 발생장치의 설계를 위한 유동해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.667-672
    • /
    • 2016
  • The goal of this study was to develop a venturi-type air bubble generator with a porous material throat. Using the two-phase multi-flow CFD analysis for the venturi tube, researchers determined the optimal design of major dimensions, such as the venturi throat length and diameter, in order to control the performance of the air bubble supply through the porous material throat in a venturi tube. Researchers then determined the relationship between the flow rate of supply water and the major design dimensions of the venturi-type air generator for maximizing the performance of the air bubble supply through the porous material throat in a venturi tube.

Surface Modification of Silicone EVD Tube by Low Temperature Plasma (저온 플라스마를 이용한 실리콘 EVD 튜브의 표면개질)

  • Lee, Y.D.;Cho, D.L.
    • Elastomers and Composites
    • /
    • v.34 no.4
    • /
    • pp.315-320
    • /
    • 1999
  • Surface modification of silicone rubber by low temperature plasma process was investigated to improve quality of silicone EVD tube by reducing tackiness and hydrophobicity. Treatment with nonpolymer-forming plasmas and thin film deposition with polymer-forming plasmas were tried. Tackiness could significantly be reduced, especially by thin film deposition. As a result, the tube became slippery and less vulnerable to contamination in laboratory environment. Inner as well as outer surface of the tube could be changed to be hydrophilic if the plasma contained oxygen. As a result, initial hydrodynamic resistance was reduced. The surface modification did not give any bad influence on mechanical properties of the silicone tube in most cases. Rather, some properties such as Young's modulus, ultimate tensile strength and elongation at break were improved.

  • PDF

Process Analysis of Elbow-shaped Tubes using a Mandrel (맨드렐을 이용한 엘보우 성형 공정해석)

  • Oh, I.Y.;Park, S.H.;Park, J.Y.;Lee, S.H.;Lee, E.Y.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.26 no.1
    • /
    • pp.11-17
    • /
    • 2017
  • In this study, process analysis of elbow-shaped tubes using a mandrel has been performed. To reach the final shape within the dimensional tolerance, the process analysis has been performed at various processing parameters such as tube dimensions, the curved cutting surface and the radius of curvature. The area outside the boundary of the target shape was expressed as a quantitative index to analyze the formability. The validation experiments have also been performed in order to increase the reliability of the process analysis. For the processing of elbow-shaped tubes, it is preferable to make the angle of the portion where the punch touches the tube smaller than the opposite angle. And the convex cutting surface is advantageous due to the increased contacts between the punch and the tube ends during the bending process. Elbow tube having larger radius of curvature shows higher dimensional accuracy due to the relatively uniform strain distribution.

Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger (수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석)

  • Lee, B.C.;Kang, H.K.;Lee, M.S.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Experimental Observations of Boiling and Flow Evolution in a Coiled Tube

  • Ye, P.;Peng, X.F.;Wu, H.L.;Meng, M.;Gong, Y. Eric
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2008
  • A sequence of visually experimental observations was conducted to investigate the flow boiling and two-phase flow in a coiled tube. Different boiling modes and bubble dynamical evolutions were identified for better recognizing the phenomena and understanding the two-phase flow evolution and heat transfer mechanisms. The dissolved gases and remained vapor would serve as foreign nucleation sites, and together with the effect of buoyancy, centrifugal force and liquid flow, these also induce very different flow boiling nucleation, boiling modes, bubble dynamical behavior, and further the boiling heat transfer performance. Bubbly flow, plug flow, slug flow, stratified/wavy flow and annular flow were observed during the boiling process in the coiled tube. Particularly the effects of flow reconstructing and thermal non-equilibrium release in the bends were noted and discussed with the physical understanding. Coupled with the effects of the buoyancy, centrifugal force and inertia or momentum ratio of the two fluids, the flow reconstructing and thermal non-equilibrium release effects have critical importance for flow pattern in the bends and flow evolution in next straight sections.

Nonlinear numerical analysis and proposed equation for axial loading capacity of concrete filled steel tube column with initial imperfection

  • Ahmad, Haseeb;Fahad, Muhammad;Aslam, Muhammad
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.81-105
    • /
    • 2022
  • The use of concrete filled steel tube (CFST) column is widely accepted due to its property of high axial load carrying capacity, more ductility and more resistant to earthquake specially using in bridges and high-rise buildings. The initial imperfection (δ) that produces during casting or fixing causes the reduction in load carrying capacity, this is the reason, experimental capacity is always less then theoretical one. In this research, the effect of δ on load carrying capacity and behavior of concrete filled steel tube (CFST) column have been investigated by numerically simulation of large number of models with different δ and other geometric parameters that include length (L), width (B), steel tube thickness (t), f'c and fy. Finite element analysis software ANSYS v18 is used to develop model of SCFST column to evaluate strength capacity, buckling and failure pattern of member which is applied during experimental study under cyclic axial loading. After validation of results, 42 models with different parameters are evaluated to develop empirical equation predicting axial load carrying capacity for different value of δ. Results indicate that empirical equation shows the 0 to 9% error for finite element analysis Forty-two models in comparison with ANSYS results, respectively. Empirical equation can be used for predicting the axial capacity of early estimating the axial capacity of SCFT column including 𝛿.

HOLD EFFECT IN FINITE TORSION OF A COMPRESSIBLE ELASTIC TUBE

  • Akinola, A.P;Layeni, O.P;Ldejobi, O.A.;Umoru, L.E.
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.323-336
    • /
    • 2004
  • We consider the application of complex variable method to elastic problem and investigate the nonlinear effect of finite torsion of a compressible elastic composite layer. We obtain that as a result of finite deformation approach, a tube subjected to torsion decreases in radius giving rise to a “hold effect”.

Advances In Air-Cooled Heat Exchanger Technology for Residential Air-Conditioning

  • Webb Ralph L.;Kim Nae-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.184-195
    • /
    • 2005
  • This paper describes the recent work on advanced technology concepts applied to air cooled heat exchangers for residential air-conditioning. The concepts include vortex generators for the air-side, micro-fin or flat tubes for the refrigerant-side. Advances in understanding of heat transfer mechanisms, predictive models are discussed.