• Title/Summary/Keyword: L-G-L(Liquid-Gas-Liquid)

Search Result 112, Processing Time 0.03 seconds

Quantitative Determination of Phenol in Water Using GC-MS after Liquid-Liquid Extraction and Acetylation (액-액 추출과 아세틸화 후 GC-MS를 이용한 물 중 phenol의 분석)

  • Park, Sunyoung;Kim, Yunjeong;Jung, Sungjin;Kim, Hekap
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.1
    • /
    • pp.63-66
    • /
    • 2017
  • BACKGROUND: The phenol concentrations in water samples were determined using gas chromatography after derivatization of the analyte to phenyl acetate followed by extraction using a large volume of solvent. However, this procedure requires an additional purification step and is not analytically efficient. METHODS AND RESULTS: In this study, phenol was first extracted from an acidified water sample using ethyl acetate and then acetylated using acetic anhydride in the presence of a small amount of water and $K_2CO_3$. The derivative was extracted using 1mL of n-butyl acetate. One microliter of the extract was analyzed by GC-MS without further purification. The calibration curve showed good linearity with the $r^2$ value of 0.9968. The method detection limit and the limit of quantitation were estimated to be $0.18{\mu}g/L$ and $0.56{\mu}g/L$, respectively. Repeatability (RSD, n=3) and recovery (n=3) were 9.1%-4.3% and 90.6%-110.5%, respectively. The concentrations of phenol in a few samples of stream water were distributed in the range of $2.51-7.51{\mu}g/L$. CONCLUSION: This method is simpler and faster to implement than those currently utilized and shows high analytical reliability. It can be applied to the quantitative determination of phenol concentrations in surface water and groundwater samples.

Effect of Limestone Particle Size on the performance of FGD system (석회석 입도에 따른 습식배연탈황 성능연구)

  • Lee, Kyeong-Woo;Hwang, Jae Dong;Woo, Kwangje;Jang, Gil Hong
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 2001
  • Limestone has been used as absorbent in the FGD(Flue Gas Desulfurization) system, the DeSOx system of thermal power plant. This study investigated the desulfurization characteristics of the two different limestones, 325mesh and 200mesh particle size. Experimental analysis showed that the dissolving rate of limestone became much slower as the particle size increased. But the desulfurization efficiency depended on the L/G(liquid/gas) ratio and slurry pH regardless of the limestone particle size. The quality of gypsum produced in the FGD process increased as the limestone particle size or the slurry pH decreased. To reduce the cost of absorbent, the mixed limestone which were composed of 200 and 325mesh limestone with 5 different ratios were tested.

  • PDF

Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.233-236
    • /
    • 2004
  • Total impurity analysis of a primary standard solution is one of the essential procedures to determine an accurate concentration of the standard solution by the gravimetry. Bi impurity is determined in Pb standard solutions by inductively coupled plasma mass spectrometry (ICP-MS). The direct nebulization of the Pb standard solution produces a significant amount of the Pb matrix-induced molecular ions which give rise to a serious spectral interference to the Bi determination. In order to avoid the spectral interference from the interferent $^{208}PbH^+$, the hydride generation method is employed for the matrix separation. The Bi hydride vapor is generated by reaction of the sample solution with 1% sodium borohydride solution. The vapor is then directed by argon carrier gas into the ICP after separation from the mixture solution in a liquid-gas separator made of a polytetrafluoroethylene membrane tube. The presence of 1000 ${\mu}$g/mL Pb matrix caused reduction of the bismuthine generation efficiency by about 40%. The standard addition method is used to overcome the chemical interference from the Pb matrix. Optimum conditions are investigated for the hydride-generation ICPMS. The detection limit of this method is 0.5 pg/mL for the sample solutions containing 1000 ${\mu}$g/mL Pb matrix.

Determination of 105 pesticide residues by GC/MS/MS (GC/MS/MS를 이용한 105종의 잔류농약 분석에 관한 연구)

  • Kim, W.S.;Do, J.A.;Lee, H.J.;Lee, J.Y.;Yang, S.J.;Lee, S.H.
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.395-404
    • /
    • 2010
  • A multi-residual method using gas chromatography coupled with mass spectrometry (GC/MS/ MS) was developed for the analysis of 105 pesticides. This method was tested on lemons, beans and other vegetables. The pretreatment of these pesticides was performed by liquid-liquid partition followed by cleanup with solid phase extraction cartridge (SPE Florisil), after acetonitrile extraction from matrices and sodium chloride (15 g) addition. The recovery ranged from 71.1% to 126.0% except for azinphosmethyl, famoxadone, fenamidone, flufenoxuron and triadimefon in lemons and from 72.5% to 124.5% in bean. In lemon, the limit of detection (LOD) and limit of quantification (LOQ) were 0.001~150 ng/ mL and 0.004~500 ng/mL, respectively.

The Effects of Extracts from Mugwort on the Blood Ethanol Concentration and Liver Function (쑥추출물이 혈중 에탄올 농도와 간기능에 미치는 효과)

  • 김민준;이치호
    • Food Science of Animal Resources
    • /
    • v.18 no.4
    • /
    • pp.348-357
    • /
    • 1998
  • This study was conducted to investigate the effects of mugwort extracts on the blood ethanol concentration and liver function in rats. Sprague-Dawley rats were used, the rats administered with 25% ethanol (5g/kg$.$B.W.) were devided into three groups (CON-E ; 25% ethanol administered to the CON-E) according to the administered ethanol concentration and the levels of administered mugwonts. Mugwont roots extracts were administered via the caudal vein. Ethanol concentration was measured at the time of 0, 1, 2 and 3hr by gas chromatography. GOT(Glutamic Oxaloacetic Transaminase) and GPT(Glutamic Pyruvic Transaminase) were measured at the time of 0 and 5hr. Components of each extracts were analyzed by using high performance liquid chromatography. Cell number, GOT and GPT were investigated by using rat hepatocyte culture. Megwort extracts were added at the levels of 1% or 2%. Hepatocyte culture were into five groups according to the addition levels. The results were summarized as follows ; 1. Catechin contents of 8∼10mg/100g and the contents of (-)-epigallocatechin was high in the water extracts. 2. Ethanol degradation efficiency declines in the following order : MDW-E>MOH-E>CON-E. 3. The numbers of rat hepatocytes declines in the following order : 2% MDW-L>1%MDW-L>1%MOH-L>CON-L>2%MOH-L. These results suggest that crude catechin of mugwort extracts may play important roles to degrade ethanol and recover liver function in rats.

  • PDF

Two-Phase Flow Characteristics in an Adiabatic Horizontal Tube (단열 수평관내 이상류의 유동특성)

  • Choi, B.H.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • Two-phase loop systems using the latent heat capacity of their working fluids can meet the increasing power requirements and are well suited to thermal management systems of future large applications, due to its abilities to handle large heat loads and to provide them at uniform temperatures regardless of the changes in the heat loads. Therefore some experiments on the effect of the gas and liquid superficial velocities, $j_G,\;j_L$ on flow pattern transition, void fraction and frictional pressure loss were performed on a co-current air-water flow in an adiabatic horizontal tube. The flow patterns were depended on the superficial velocity of each phase. It snowed that the increasing $j_L$, resulted in a significant increase in the frictional pressure loss for all flow patterns, at a constant $j_G$. The experimental results were also evaluated with some of existing models and correlations.

  • PDF

Acute cocaine intoxication in a body packer

  • Park, Mee-Jung;Lim, Mi-Ae;Chung, Hee-Sun
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.103-106
    • /
    • 2006
  • A 35-year-old Perubian who suffered from grand mal seizures died in the aircraft on his way from the United States to Hongkong via Incheon international airport of Korea. While performing the autopsy, 115 packs made with double layer of transparent film and black plastic bag containing cocaine were found in the ileum and large intestine. Among of them, 3 packs were ruptured. To determine the concentration of cocaine and its metabolites, blood, urine, bile, liver, spleen, heart, kidney, brain and gastric contents were taken and toxicological analysis was performed. Gas chromatography/mass spectrometry (GC/MS) following liquid-phase extraction using chloroform:isopropanol (=9:1) and derivatization with bis(trimethylsilyl)-trifluoroacetamide (contains 1% trimethylchlorosilane) was performed. High levels of cocaine, benzoylecgonine (BE) and ecgonine methylester (EME) were found in the postmortem blood (0.96, 3.09 and $5.59{\mu}g/mL$) and urine (32.85, 145.35 and $53.17{\mu}g/mL$), respectively. Cocaine and its metabolites were also detected in all other biological specimen.

NEAR-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW USING WALL BOILING MODEL (벽 비등모델을 이용한 과냉비등 유동에 대한 CFD 모의계산에서 벽 인접격자의 영향)

  • In, W.K.;Shin, C.H.;Chun, T.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2010
  • boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and gas(vapour) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit for lqiuid phase ($y^+_{w,l}$) was examined from 101 to 313 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y^+_{w,l}$ > 300 at the tube exit.

Myo-Inositol Synthesis in the Milk of Lactating Rats (쥐 우유중의 Myo-Inositol 생성에 관한 연구)

  • Byun, Si-Myung
    • Applied Biological Chemistry
    • /
    • v.19 no.3
    • /
    • pp.121-129
    • /
    • 1976
  • A high concentration of myo-Inositol in rat's milk was observed (61-91mg. of myo-Inositol per 100g of milk) by gas-liquid chromatographic method, using a 3% SE-52 column. Feeding experiments showed that approximately 85% of myo-Inositol in milk was from dietary origin: the rest was considered to be synthesized by 1L-myo-Inositol-1-phosphate lyase. Results suggested that the biosynthesis was not sufficiently high to permit the maintenance of its myo-Inositol level in milk. However, study $using(^{14}C)-glucose$ injection into lactating female rats confirmed biosynthesis of myo-Inositol from glucose in mammary gland. This biosynthesis reached a maximum within an hour after $(^{14}C)-glucose$ injection intraperitoneally as lactose biosynthesis did. Study using $(^3H)-myo-Inositol$ confirmed that most of the myo-Inositol in milk was transported from blood plasma myo-Inositol against a concentration gradient. About four hours after the beginning of the injection of $(^{14}C)-glucose$, the specific radioactivity of myo-Inositol in milk was 8% of that of glucose in the blood. When $(^3H)-myo-Inositol$ was injected, the specific radioactivity of myo-Inositol in milk was about 26% of that of blood six hours after injection.

  • PDF

Application of Subirrigation Using Capillary Wick System to Pot Production

  • Lee, Chi-Won;So, In-Sup;Jeong, Sung-Woo;Huh, Moo-Ryong
    • Journal of agriculture & life science
    • /
    • v.44 no.3
    • /
    • pp.7-14
    • /
    • 2010
  • Alternative subirrigation way, capillary wick system (CWS) was tested to reduce labor cost, waste water, contamination of ground water, and use of fungicide compared to overhead irrigation system (OIS). CWS helped reduce remarkably the working hours for watering from 4 hours in OSI to just 5 minutes. Labor cost was saved 98% in CWS compared to OIS. By the physical characteristics of various growing media, 1 coconut coir+2 perlite (v/v) mixture was selected because it had an ideal distribution of three phase, e.g. 1 solid: 1 liquid: 2 gas phase. Medium mixture containing scoria had so high bulk and particle density to hurt root. In bark-containing medium, the liquid phase and the percent saturation of liquid phase with time elapsed was lower than that of other mixture. It meant that the mixture contained very low level of water. Application of CWS for cyclamen pot production played an important role in reducing the incident of fusarium wilt symptom from 18% in conventional over watering system to 4%. Cyclamen pot irrigated by capillary wick had shorter petiole and more leaves than those by overhead watering. As a result, this system was highly beneficial to get uniform pot products with high quality. It improved water and nutrient solution efficiency relative to conventional overhead irrigation system (OIS).