• Title/Summary/Keyword: Kruskal-Wallis Test

Search Result 616, Processing Time 0.025 seconds

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

Relationship between 18F-FDG PET/CT Semi-Quantitative Parameters and International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society Classification in Lung Adenocarcinomas

  • Lihong Bu;NingTu;Ke Wang;Ying Zhou;Xinli Xie;Xingmin Han;Huiqin Lin;Hongyan Feng
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.112-123
    • /
    • 2022
  • Objective: To investigate the relationship between 18F-FDG PET/CT semi-quantitative parameters and the International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society (IASLC/ATS/ERS) histopathologic classification, including histological subtypes, proliferation activity, and somatic mutations. Materials and Methods: This retrospective study included 419 patients (150 males, 269 females; median age, 59.0 years; age range, 23.0-84.0 years) who had undergone surgical removal of stage IA-IIIA lung adenocarcinoma and had preoperative PET/CT data of lung tumors. The maximum standardized uptake values (SUVmax), background-subtracted volume (BSV), and background-subtracted lesion activity (BSL) derived from PET/CT were measured. The IASLC/ATS/ERS subtypes, Ki67 score, and epidermal growth factor/anaplastic lymphoma kinase (EGFR/ALK) mutation status were evaluated. The PET/CT semi-quantitative parameters were compared between the tumor subtypes using the Mann-Whitney U test or the Kruskal-Wallis test. The optimum cutoff values of the PET/CT semi-quantitative parameters for distinguishing the IASLC/ATS/ERS subtypes were calculated using receiver operating characteristic curve analysis. The correlation between the PET/CT semi-quantitative parameters and pathological parameters was analyzed using Spearman's correlation. Statistical significance was set at p < 0.05. Results: SUVmax, BSV, and BSL values were significantly higher in invasive adenocarcinoma (IA) than in minimally IA (MIA), and the values were higher in MIA than in adenocarcinoma in situ (AIS) (all p < 0.05). Remarkably, an SUVmax of 0.90 and a BSL of 3.62 were shown to be the optimal cutoff values for differentiating MIA from AIS, manifesting as pure ground-glass nodules with 100% sensitivity and specificity. Metabolic-volumetric parameters (BSV and BSL) were better potential independent factors than metabolic parameters (SUVmax) in differentiating growth patterns. SUVmax and BSL, rather than BSV, were strongly or moderately correlated with Ki67 in most subtypes, except for the micropapillary and solid predominant groups. PET/CT parameters were not correlated with EGFR/ALK mutation status. Conclusion: As noninvasive surrogates, preoperative PET/CT semi-quantitative parameters could imply IASLC/ATS/ERS subtypes and Ki67 index and thus may contribute to improved management of precise surgery and postoperative adjuvant therapy.

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Comparison of Urologist Satisfaction for Different Types of Prostate MRI Reports: A Large Sample Investigation

  • Jinman Zhong;Weijun Qin;Yu Li;Yang Wang;Yi Huan;Jing Ren
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1326-1333
    • /
    • 2020
  • Objective: To evaluate urologist satisfaction on structured prostate MRI reports, including report with tumor-node-metastasis (TNM) staging (report B) and with Prostate Imaging Reporting and Data System (PI-RADS) score with/without TNM staging (report C, report with PI-RADS score only [report C-a] and report with PI-RADS score and TNM staging [C-b]) compared with conventional free-text report (report A). Materials and Methods: This was a prospective comparative study. Altogether, 3015 prostate MRI reports including reports A, B, C-a, and C-b were rated by 13 urologists using a 5-point Likert Scale. A questionnaire was used to assess urologist satisfaction based on the following parameters: correctness, practicality, and urologist subjectivity. Kruskal-Wallis H-test followed by Nemenyi test was used to compare urologists' satisfaction parameters for each report type. The rate of urologist-radiologist recalls for each report type was calculated. Results: Reports B and C including its subtypes had higher ratings of satisfaction than report A for overall satisfaction degree, and parameters of correctness, practicality, and subjectivity (p < 0.05). There was a significant difference between report B and C (p < 0.05) in practicality score, but no statistical difference was found in overall satisfaction degree, and correctness and subjectivity scores (p > 0.05). Compared with report C-b (p > 0.05), report B and C-a (p < 0.05) showed a significant difference in overall satisfaction degree and parameters of practicality and subjectivity. In terms of correctness score, neither report C-a nor C-b had a significant difference with report B (p > 0.05). No statistical difference was found between report C-a and C-b in overall satisfaction degree and all three parameters (p > 0.05). The rate of urologist-radiologist recalls for reports A, B, C-a and C-b were 29.1%, 10.8%, 18.1% and 11.2%, respectively. Conclusion: Structured reports, either using TNM or PI-RADS are highly preferred over conventional free-text reports and lead to fewer report-related post-hoc inquiries from urologists.

Comparison between village characteristics and habitat quality to application OECM in Nakdong-Jeongmaek (낙동정맥 내 OECM 적용 가능 지역 발굴을 위한 마을 특성과 서식지 질 비교)

  • Oh, Ju-Hyeong;Kim, Su-Jin;Kim, Tae-Su;Jang, Gab-Su;Jeon, Seong-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.26 no.6
    • /
    • pp.51-65
    • /
    • 2023
  • The Jeongmaeks are Korea's unique forest space recognition system that diverged from the Baekdudaegan. The Jeongmaeks are easily exposed to pressure because it is adjacent to the living area. Among them, Nakdong-Jeongmaek has high biodiversity, but damage is accelerating. According to the Convention on Biological Diversity (CBD) in 2022, the target is to expand the area of terrestrial and marine protected areas to 30% of national territory by 2030. As of September 2023, the area of terrestrial protected areas in South Korea is only 16.97% of the country's territory. This is due in part to the high proportion of private forests in the region, which makes it difficult to establish protected areas. Therefore, there is a need to establish Other Effective Area-based Conservation Measure (OECMs), which pursue complex and effective conservation that considers multiple values, as an alternative to protected areas. This study aims to identify areas suitable for OECM and to provide opinions on the establishment of appropriate management plans for each value using SOM and InVEST Habitat Quality model. This study evaluated the habitat quality of 206 villages located within 1km of the Nakdong-Jeongmaek and compared the characteristics of villages classified by SOM. As a result, the habitat quality was 0.867 for Tourism village (ClusterIV), 0.838 for Conservation village (ClusterVI), 0.835 for Mixed village (ClusterI), 0.796 for Production (ClusterV), 0.731 for Rural village (ClusterIII) and 0.625 for Urban village (ClusterII). When the distribution was identified through statistical analysis, the Kruskal-Wallis test showed that the distributions were not identical, with a p-value of 1.53e-08. Dunn's test showed a difference between Tourism, Conservation and Rural, Urban village. However, Mixed village was overestimated due to the lack of villages and the small area included in the study area. Moreover, Conservation village was somewhat under-evaluated in the analysis due to the use of a single weight for protected areas. It is necessary to perform additional reinforcement of the value evaluation of Jeongmaeks by conducting Forest Resource Survey and the National Natural Environment Survey. Therefore, we believe that sufficient validity for the establishment of OECMs in the Nakdong-Jeongmaek can be provided by addressing these limitations and conducting additional research.

Risk perceptions of a population living near a municipal waste incinerator and associated factors with the prevalence of environmental disease

  • Dong Hyun Kim;Chae Kwan Lee;Jeong Ho Kim;Byung Chul Son;Chunhui Suh;Kunhyung Kim;Byeong Jin Ye
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.38.1-38.9
    • /
    • 2022
  • Background: This study investigated the risk perceptions, prevalence of environmental diseases (EDs) and associated factors with the prevalence of environmental disease among the population living near an incinerator Methods: Study area were divided into 3 local areas near the incinerator by distance (A, B, C) and control area (D) by distance and geographic isolation. A Questionnaire was conducted with 1,380 in local residents (A, B, C) and 390 in control area (D), gathered information of demographic characteristics, lifestyle, perception of damage by incinerators, experience of EDs (atopic dermatitis, allergic rhinitis, asthma) diagnosed by physician. Analysis of variance, χ2 test, and Kruskal Wallis test was applied to determine the difference by area. Logistic regression analysis was performed to identify factors associated with the prevalence of allergic rhinitis. Results: Residents residing closer to the incinerator had negative perception in most items in questionnaire compared with control. The prevalence of allergic rhinitis was higher as they lived nearby the incinerator (p = 0.008). The associated factors with the prevalence of allergic rhinitis were carpet (odds ratio [OR]: 1.79, p = 0.001), residential area (marginally significant), duration of residence (OR: 1.09, p < 0.001). The perception of environmental pollution around the residential area was inversely associated with the prevalence of allergic rhinitis: perceived as very dissatisfied (OR: 4.21, p = 0.02) compared with very satisfied. Conclusions: As closer to the incinerator, the risk perception tend to negative and prevalence of EDs were increased. Carpet, residential area, duration of residence and perception of environmental air pollution around the residential area were associated with prevalence of allergic rhinitis. These results may be useful for the communication with residents to discuss the environmental problems caused by the incinerator.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

A Comparative Study on the Measurement Value of Yangdorak in Idiopathic Facial Paralysis and Normal Group (특발성안면신경마비환자군과 건강검진군의 양도락 진단결과에 대한 비교연구)

  • Lee, Dong-Hyun;Jeong, Yeong-Pyo;Jeong, Hyo-Keun;Kim, Hyeon-Su;Ryu, Chung-Ryul;Cho, Myung-Rae;Chae, Woo-Seok;Sul, Jae-Uk;Na, Gun-Ho
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.27-38
    • /
    • 2006
  • Objectives : The aim of the present study was to evaluate Yandorak for the wide inflection and establishment of a diagnostic system. Methods : We analyzed the measurement value of Yandorak on fifty one patients with idiopathic facial paralysis and eighty four healthy persons from April 1, 2005 to March 1, 2006 by using Yangdorak(YDRAK-94N, Sord Medicom Co., Korea). Statistical analysis was performed using the SPSS 11.0 for Windows, Mann-Whitney test for the comparisons followed side(Right and Left), sex, palsy localization in Idiopathic facial paralysis and normal group and one-way ANOVA(Kruskal Wallis) for the comparisons followed age. p < .05 was considered significant statistically. Results The difference of the electric current value of all meridian except Bladder(BL) of normal group on both side extremity was not significant statistically, Electric current value of all meridian except Gall-Bladder(GB) was more higher in idiopathic facial paralysis group than in normal group. The measurement value of Yandorak followed sex and palsy localization were not significant statistically. Conclusion : It is suggested that the measurement value of six Hand Yang & Eum channel, Liver Meridian of Foot Gworeum(厥陰) and Stomach Meridian of Foot Yangmyeong(陽明) is more higher in idiopathic facial paralysis group than in normal group.

  • PDF

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Study of Bacteria Associated with Dental Caries Using a 3 Tone Disclosing Agent (세가지 색상차이를 보이는 착색제를 이용한 치아 우식 관련 균에 관한 연구)

  • Lee, Jeongeun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • The aim of this study was to determine the efficacy of a 3 tone plaque disclosing gel in assessing the risk of caries related to the population of Streptococcus mutans, Streptococcus sobrinus, and Lactobacillus spp. quantified using a quantitative real-time polymerase chain reaction (qRT-PCR). 15 healthy children of ages 9 - 12 years were randomly examined. The 3 tone plaque disclosing gel was applied on teeth surfaces, which changed the color to pink or red, blue or purple and light blue. Plaque was divided into 3 groups based on staining. Genomic DNA from each sample was subjected to a qRT-PCR assay for quantitative detection of target bacteria. The Kruskal-Wallis test was conducted for correlation between the color of plaque and the number of bacterial species. The levels of S. mutans, S. sobrinus, and Lactobacillus spp. were significantly different in the plaque samples of the 3 groups (p < 0.05). The proportion of S. sobrinus to S. mutans showed correlation to the color of plaque. The different color-dyed plaque was related to the number of acidogenic bacteria. The 3 tone plaque disclosing gel could be used as one of the indicators to assess the clinical risk of caries associated with the population of S. mutans, S. sobrinus, and Lactobacillus spp.