• 제목/요약/키워드: Kruskal-Wallis Test

검색결과 616건 처리시간 0.027초

근관의 치경부 조기 확대가 치근단 잔사 정출에 미치는 효과 (THE EFFECT OF EARLY CORONAL FLARING ABOUT APICAL EXTRUSION OF DEBRIS)

  • 김민경;미정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.147-152
    • /
    • 2004
  • The purpose of this study was to investigate the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. Five groups of 9 endodontic resin models were instrumented using each different technique : hand instrumentation without early coronal flaring. hand instrumentation after early coronal flaring. and three nickel-titanium engine-driven instrumentations (Hero 642, Protaper, $K^$). Debris extruded from apical foramen during instrumentation was collected on preweighed CBC bottle, desiccated and weighted using electronic balance. The results were analyzed using Kruskal-wallis test and Mann-Whitney U rank sum test at a significance level of 0.05. The results were as follows: 1. All of instrumentation techniques produced apically extruded debris. 2. Group without early coronal flaring extruded significant more debris than groups with early coronal flaring. 3. There was no significant difference among early coronal flaring groups. The early coronal flaring is very important to reduce the amount of debris extruded apically.

백악질 변연을 갖는 2급 와동에 충전된 4종 복합레진의 미세누출 (MICROLEAKAGE OF 4 DIFFERENT COMPOSITE RESIN RESTORATIONS IN CLASS II CAVITY WITH CEMENTAL MARGIN)

  • 조영곤;한세희;김은성
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.492-498
    • /
    • 2001
  • The purpose of this study was to evaluate four different composite resins in vitro for microleakage in Class II box type restorations that have gingival margins apical to the cementoenamel junction. Forty caries free extracted human molars were used in this study. The Class II cavities were prepared 1.0mm below cementoenamel junction with a #701 carbide bur. The teeth were randomly divided into four groups, each group comprising 20 treated cavities according to adhesives and filling materials ; Group 1: Scotchbond Multipurpose/Z 100. Group 2: Ariston Liner/Ariston pHc, Group 3: One Step/Pyramid, Group 4: Prime & Bond NT/SureFil. To simulate the clinical situation during restoration placement, a restoration template was fabricated and composite resin was filled using a three sited light-curing incremental technique. The specimens were stored in the 100% humidity for 7 days prior to thermocycling. The specimens were immersed in 2% methylene blue dye solution for 24 hours and then embeded in transparent acrylic resin and sectioned mesiodistally with a diamond wheel saw. The degree of marginal leakage was scored under the stereomicroscope($\times$20) and the data were analyzed by Kruskal Wallis test and Mann Whitney test. (omitted)

  • PDF

Disparity between MR Imaging and Histochemical Grading in Human Intervertebral Disc Degeneration

  • Lee, June-Ho;Chung, Chun-Kee;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권6호
    • /
    • pp.432-437
    • /
    • 2006
  • Objective : In order to establish the index of degeneration, the authors performed a histochemical study with Safranin-O staining and investigated the occurrence of apoptosis in the human intervertebral disc. Methods : Eighteen intervertebral disc specimens surgically extracted from the patients and two additional specimens from the autopsied cases were stained with Safranin-O for proteoglycan according to a standard protocol. Terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate- biotin nick end labeling[TUNEL] was used to detect the fragmented DNA known to be associated with apoptotic cell death and classification scheme was formulated for categorization of the degree of Safranin-O staining [normal, moderate reduction, faint] by modification of Makin's histological-histochemical grading. The Kruskal-Wallis H test and Chi-square test were used for statistical analysis. Results : The statistical results showed a significant difference in the mean age between "normal" Safranin-O staining group and the others [19.3 versus 55, 43.4, p=0021]. However, there was no statistically significant correlation between Safranin-O staining and MR grading of disc degeneration. Only six of eighteen surgical specimens and none in autopsies showed positive apoptotic cells in TUNEL staining. Conclusion : The determination of the degree of degeneration in surgically obtained disc tissue per se by histochemical staining or by the degree of apoptosis that corresponds to its morphologic change was not feasible.

119 구급 서비스의 미이송 시간 분석 (Analysis of response time for patient non-transport by 119 ambulance services)

  • 강경희;한진옥
    • 한국응급구조학회지
    • /
    • 제22권3호
    • /
    • pp.177-187
    • /
    • 2018
  • Purpose: The purpose of the study was to investigate the causes of non-transport in 119 ambulance services and to describe the difference in response time according to the reason for non-transport. Methods: This study analyzed 42,415 non-transport cases out of 123,158 cases using prehospital care reports in a metropolitan city. The Kruskal-Wallis test and the Wilcoxon-Mann-Whitney test were used to 6,857 cases for which time was recorded. Results: Non-transportation in 20${\bigcirc}{\bigcirc}$ comprised 33.1% of all ambulance services. The reason for non-transport were other reasons (25.5%), cancellation (23.8%), and moving to other vehicles (21.7%). There were differences in ambulance service times according to the reasons for non-transport. The activation interval was the longest (2.68 minutes) in the absence of the patient, and the response interval was the shortest (4.96 minutes) among the cancelled case. The total interval was the shortest time (21.97 minutes) in the cancellation cases and the longest time among the death cases (32.23 minutes). Conclusion: It is important to suggest the direction of development of emergency services by identifying the reasons for non-transport by ambulance services and describing the response time according to the reason for non-transport.

Successful vs. Failed Tech Start-ups in India: What Are the Distinctive Features?

  • Kalyanasundaram, Ganesaraman;Ramachandrula, Sitaram;Subrahmanya MH, Bala
    • Asian Journal of Innovation and Policy
    • /
    • 제9권3호
    • /
    • pp.308-338
    • /
    • 2020
  • The entrepreneurial journey is not short of challenges, and about 90% + tech start-ups experience failure (Startup Genome, 2019). The magnitude of the challenges varies across the tech start-up lifecycle stages, namely emergence, stability, and growth. This opens the research question, do the profiles of a start-up and its co-founder impact start-up success or failure across its lifecycle stages? This study aims to understand and identify the profiles of tech start-ups and their co-founders. We gathered primary data from 151 start-ups (Status: 101 failed and 50 successful ones), and they are across different lifecycle stages and represent six major start-up hubs in India. The chi-square test on status and start-up's lifecycle stage indicates a noticeable correlation, and they are not independent. The Kruskal Wallis test was used to distinguish statistically significant profile attributes. The parameters distinguishing success and failure are identified, and the need to deliver customer experience is emphasized by the start-up profile attributes: Product/service, high-tech nature of a start-up, investor fund availed, co-founder experience, and employee count. The importance of entrepreneurial experience is ascertained with entrepreneur profile attributes: Entrepreneurial expertise, the number of prior and current start-ups, their willingness to start again in the event of failure, and age of co-founder, which is a proxy to learning and experience. This study has implications for entrepreneurs, investors, and policymakers.

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.

치과 3D 프린팅용 광중합 시간에 따른 중합도 비교 (Comparison of polymerization by time of light curing for dental 3D printing)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

Educational Status and Needs of Premature Birth Prevention and Its Association with Preconception Health Behavior among Women of Childbearing Age in Korea

  • Kim, Sun-Hee;Hong, Ji-Yeon;Park, Mi Kyung
    • 지역사회간호학회지
    • /
    • 제33권4호
    • /
    • pp.372-384
    • /
    • 2022
  • Purpose: The aim of this study was to investigate the educational status and needs of premature birth prevention, and to identify factors associated with preconception health behaviors. Methods: The study design was a crosssectional descriptive study. Data were collected through an online questionnaire survey, and the subjects were 192 women of childbearing age in Korea. Data were analyzed using the Mann-Whitney U test, Kruskal-Wallis test, Spearman's correlation coefficients, and multiple regression. Results: The proportion of subjects who received education on premature birth prevention was 8.9%, and 75.5% of subjects answered that they needed education on premature birth prevention. They demanded education through online media, small groups, cases, cartoons (webtoon) with stories, pictures, and videos. A related factor of preconception health behavior was self-efficacy for high-risk pregnancy health care (β=.20, p=.012), which accounted for 8.2% of the total variance related to preconception health behavior. Conclusion: There was a need for more development of education programs to prevent premature birth for women of childbearing age. Its education programs should be applied with online, small group activities using various educational media. It is also required to promote preconception health behavior through self-efficacy for high-risk pregnancy health care.

내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향 (Influence of internal connection length on screw loosening in internal connection implants)

  • 김지선;박영범;최현민;김성태;김현철;김선재;문홍석;이재훈
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.251-257
    • /
    • 2017
  • 목적:본 연구에서는 long internal connection 형태의 임플란트 지대주를 내부 연결 길이에 변화를 주어 임플란트-지대주 결합부의 안정성을 비교 평가해 보고자 하였다. 재료 및 방법: Long internal connection의 임플란트(Replus system, $4.7{\times}11.5mm$)를 각각 지대주의 길이에 따라 4개의 군(1, 2, 3, 4 mm 군)으로 나누었고 총 20개의 시편을 사용하였다. 시편을 레진에 매몰하여 고정시키고 100 N의 힘으로 임플란트 장축에 대해 30도의 각도에서 $1.0{\times}10^6$ 번의 반복하중을 가한 후 하중 전 후의 풀림회전력의 차이를 계산하여 95% 유의수준에서 Kruskal-Wallis 검정 방법을 통해 통계 분석하였다. 결과:지대주 내부 길이에 따른 풀림 회전력의 통계적 유의성은 나타나지 않았으며 (P > .05) 어떤 시편에서도 완전한 나사 풀림이나 나사 파절은 관찰되지 않았다. 결론: 내측 연결 임플란트에서 지대주 내부길이에 따른 나사 풀림의 정도는 차이가 나지 않았다.

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.