• Title/Summary/Keyword: Korean tooth models

Search Result 246, Processing Time 0.031 seconds

Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type

  • Ha, Seung-Ryong
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.475-483
    • /
    • 2015
  • PURPOSE. The objective of this study was to evaluate the influence of various cement types on the stress distribution in monolithic zirconia crowns under maximum bite force using the finite element analysis. MATERIALS AND METHODS. The models of the prepared #46 crown (deep chamfer margin) were scanned and solid models composed of the monolithic zirconia crown, cement layer, and prepared tooth were produced using the computer-aided design technology and were subsequently translated into 3-dimensional finite element models. Four models were prepared according to different cement types (zinc phosphate, polycarboxylate, glass ionomer, and resin). A load of 700 N was applied vertically on the crowns (8 loading points). Maximum principal stress was determined. RESULTS. Zinc phosphate cement had a greater stress concentration in the cement layer, while polycarboxylate cement had a greater stress concentration on the distal surface of the monolithic zirconia crown and abutment tooth. Resin cement and glass ionomer cement showed similar patterns, but resin cement showed a lower stress distribution on the lingual and mesial surface of the cement layer. CONCLUSION. The test results indicate that the use of different luting agents that have various elastic moduli has an impact on the stress distribution of the monolithic zirconia crowns, cement layers, and abutment tooth. Resin cement is recommended for the luting agent of the monolithic zirconia crowns.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps

  • Kim, Soo-Hyun;Park, Young-Seok;Kim, Min-Kyoung;Kim, Sulhee;Lee, Seung-Pyo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.124-134
    • /
    • 2018
  • Purpose: Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methosds of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative parameters using the cusp area and volume of virtual dental models. Methods: The subjects of this study were the same virtual models that were used in our former study. The same age group classification and new tooth wear index (NTWI) scoring system were also reused. A virtual occlusal plane was generated with the highest cusp points and lowered vertically from 0.2 to 0.8 mm to create offset planes. The area and volume of each cusp was then measured and added together. In addition to the former analysis, the differential features of each cusp were analyzed. Results: The scores of the new parameters differentiated the age and NTWI groups better than those analyzed in the former study. The Spearman ${\rho}$ coefficients between the total area and the area of each cusp also showed higher scores at the levels of 0.6 mm (0.6A) and 0.8A. The mesiolingual cusp (MLC) showed a statistically significant difference (P<0.01) from the other cusps in the paired t-test. Additionally, the MLC exhibited the highest percentage of change at 0.6A in some age and NTWI groups. Regarding the age groups, the MLC showed the highest score in groups 1 and 2. For the NTWI groups, the MLC was not significantly different in groups 3 and 4. These results support the proposal that the lingual cusp exhibits rapid wear because it serves as a functional cusp. Conclusions: Although this study has limitations due to its cross-sectional nature, it suggests better quantitative parameters and analytical tools for the characteristics of cusp wear.

Evaluation of adjacent tooth displacement in the posterior implant restoration with proximal contact loss by superimposition of digital models

  • Jo, Deuk-Won;Kwon, Min-Jung;Kim, Jong-Hee;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.88-94
    • /
    • 2019
  • PURPOSE. This study was conducted to investigate patterns of adjacent tooth displacement in the posterior implant with interproximal contact loss (ICL) by 3-D digital superimposition method. MATERIALS AND METHODS. Posterior partially edentulous patients, restored with implant fixed partial prostheses before 2011 and suffered from food impaction of ICL between 2009 and 2011, were included. Two dental casts, at the time of delivery and at the time of food impaction in a same patient, was converted into 3-D digital models through scanning and superimposition was performed to assess chronologic changes of the dentition. Directions of tooth displacement were evaluated and the amount of ICL was calculated. Correlations between the amount of ICL and elapsed time, or between the amount of ICL and age after function, were assessed at a significance level of P<.05. RESULTS. A total number of 13 patients (8 males, 5 females) with a mean age of $65.76{\pm}9.94years$ and 17 areas (4 maxillae, 13 mandibles) were included in this retrospective study. Teeth adjacent to the implant restoration showed complex displacements but characteristic tendency according to the location of the arch. The mean amount of ICL was $0.33{\pm}0.14mm$. Elapsed time from function to ICL was $61.47{\pm}31.27months$. There were no significant differences between the amount of ICL and elapsed time, or age (P>.05). CONCLUSION. Natural teeth showed various directional movements to result in occlusal change in the arch. The 3-D superimposition of chronologic digital models was a helpful method to analyze the changes of dentition and individual tooth displacement adjacent to implant restoration.

INFLUENCE OF INDIVIDUAL TOOTH TRAY ON THE TEETH WITH UNDERCUT IN IMPRESSION TAKING (언더컷이 있는 치아에서 개별 치아 트레이가 인상채득에 미치는 영향)

  • Seo Kowang-Won;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Problem : The several studies were reported to the effects of individual tooth tray with the parallel tooth, but not reported to the effect of individual tooth tray with severe undercut in impression making. Purpose : The purpose of this study is to examine the effect of individual tooth tray; 1) the accuracy of impression in terms of distance. 2) reproducibility of pocket. Material and methods : In this study, a metal model with 3 teeth including tooth prepared 30-degree undercut and gingival crevice of the depth 5mm, width 0.4mm was cast. Impressions of the metal model were taken in 5 times used 4 kinds of impression materials with individual tooth tray and another impression taking were made with conventional method without individual tooth, used same materials, procedure. The stone models were made. Distances between abutments were measured with a Micromeasurescoup-mm. Result : The following results were obtained ; 1. In the comparisonof inter-abutment distance between parallel tooth without individual tooth tray, 4elastomeric materials have not significant difference to the metal model(p>0.05). 2. In the comparisonof inter-abutment distance with undercut tooth without individual tooth tray, 4elastomeric materials have a significant difference to the metal model(p<0.05), especially polyether's dimensional change is large. 3. If individual tooth tray was used to take impression in abutment teeth with severe undercut, more stable results was achieved easily than conventional method. (p>0.05). 4. It is not true that the pressure of impression material with individual tooth tray increased to gingival sulcus. Conclusion : By the results, I knew the fact that individual tooth tray was useful impression method on the teeth with severe undercut for the dimensional stability. Also, I could not confirm the fact that individual tooth tray would increase the penetrating pressure into cervice.

Achievement of Anterior Teeth Arrangement Using a Single Stage of Clear Aligner

  • Ryu, Seon-Jeong;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.90-100
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the degree of achievement of anterior tooth movement using a thermoplastic clear aligner by superimposing pretreatment, setup, and post-treatment models and to analyze the factors that influence it. Materials and Methods: Forty patients who underwent clear aligner treatment at the Department of Orthodontics were included in the study. The pretreatment, setup, and post-treatment models were superimposed, and the achievement rates were evaluated. We analyzed the factors that caused changes in achievement rate on each condition. Result: The average achievement rate of total tooth movement was 57.65%. Mesiodistal and anteroposterior displacements were achieved better than vertical displacement and rotation. In each displacement, posterior, mesial, and extrusive movements were better achieved than the rotation. Spacing was better corrected than crowding, especially in the mesiodistal direction. Most of the tooth movements were achieved better when using 3-step thicknesses of aligners were used. Conclusion: The treatment results of clear aligners may differ depending on the type of tooth movement, age and other treatment conditions. Clinicians should consider unfavorable conditions based on the results of this study.

The influence of leukocyte-platelet-rich plasma on accelerated orthodontic tooth movement in rabbits

  • Nakornnoi, Theerasak;Leethanakul, Chidchanok;Samruajbenjakun, Bancha
    • The korean journal of orthodontics
    • /
    • v.49 no.6
    • /
    • pp.372-380
    • /
    • 2019
  • Objective: To determine the effects of a local injection of leukocyte-platelet-rich plasma (L-PRP) on orthodontic tooth movement in rabbits. Methods: Twenty-three male New Zealand white rabbits were included in a split-mouth design. Tooth movement with a 100-g nickel-titanium closed-coil spring was performed on the maxillary first premolars. L-PRP was injected submucosally at the buccal and lingual areas of the first premolar in one random side of the maxilla and the other side served as the control and received normal saline. The amount of tooth movement was assessed on three-dimensional digital models on days 0, 3, 7, 14, 21, and 28. Histological findings and osteoclast numbers were examined on day 0 as the baseline and on days 7, 14, and 28. Results: The L-PRP group showed significantly greater cumulative tooth movement at all observed periods. However, a significantly higher rate of tooth movement was observed only on days 0-7 and 7-14. The osteoclast numbers were significantly increased in the L-PRP group on days 7 and 14. Conclusions: Local injection of L-PRP resulted in a transient increase in the rate of tooth movement and higher osteoclast numbers.

A Study on the Thrust and Normal force Characteristics by Tooth Shapes of HLSM (HLSM의 치 형상에 따른 추력 및 수직력 특성에 관한 연구)

  • 이상호;오홍석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.318-324
    • /
    • 2004
  • In the recently, the necessity of linear position control motors have been increased in the various fields of the automatic control system. In this paper, we have designed the tooth models of the hybrid type linear stepping motor(HLSM); rectangular type(RT), triangle type(TrT), round type(RdT) and wedge type(WT), and proposed the optimum tooth shape of the HLSM by simulating(Flux2D) the thrust and normal force characteristics with the finite element method(FEM) and the virtual work method. And we have manufactured the prototype HLSM with the optimum tooth, and measured the various values by using experimental system. Thus, we have confirmed the justice of theory because the computed and the experimental results almost coincide with.

A STUDY ON THE CONFIGURATION OF THE BRISTLE FOR THE PROSTHETIC AND PERIODONTALLY INVOLVED PATIENT (고정성보철물 장착환자 및 치주질환 이환자를 위한 잇솔의 식모에 관한 연구)

  • Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.867-877
    • /
    • 1998
  • The purpose of this study was to investigate the ideal locations and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis. The models of 16 pts were analysed and the resullts were as follows: 1. There were no tooth brushes in the market, which were proper for the patients who were installed with fixed prostheses and had severely periodontally involved teeth. 2. The neck portion of the tooth brush should be narrow as possblly. 3. The size of tooth brush should be analyzed by the size of arch. 4. The width of tooth brush should be analyzed by the degree of bone recession. 5. The custom made tooth brush may be ideal, if possible.

  • PDF

An experimental study on plaque removal effect through the acting types of the electric toothbrushes (전동칫솔모의 작동형태에 따른 치면세균막 제거율에 관한 실험연구)

  • Lee, Cheon-Hee;Ahn, Sun-Ha;Jang, Young-Ho
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.465-474
    • /
    • 2011
  • Objectives : The removal of most reliable mechanical dental plaque that is to say tooth brushing was generalized to control of dental plaque, many oral health goods have also developed due to the effect differences followed by individual habit. The electric toothbrush have studied and developed widely as major field of study that electric toothbrush having various moving phase was sold and developed at the market. Methods : Accordingly author studied about selling electric toothbrushes shape (vibration type, ultra-sonic minuteness vibration type, semi rotation type) to raise the efficiency after comparing to the moving them that total 8 groups classified by poor tooth models for example normal set of tooth, crowding tooth, bracket attached tooth, prosthetic status etc. and executed plaque removal effect on the tooth through comparing experiment. Results : The removal rate of artificial plaque on the tooth was improved in proportion to the increase of tooth brushing time(p<0.05). The ultra-sonic minuteness vibration and semi rotation type was superior to toothbrush of vibration type comparing to the removal rate of plaque on the tooth(p<0.05). Conclusions : The electric toothbrush of supersonic minuteness vibration and semi rotation type can be recommended most of tooth types regardless of oral tooth setting status for example, normal set of tooth, crowding tooth, bracket attached tooth, porcelain tooth.