• Title/Summary/Keyword: Korean surface temperature

Search Result 12,774, Processing Time 0.045 seconds

Heat Shield Property of Nanostructural-regulated Fe2O3/TiO2 Composites Filled with Polyacrylate Paint (나노구조 변화에 의한 Fe2O3/TiO2 복합재료를 충전한 Poly Acrylate 도료의 열차단 특성)

  • Kim, Dae Won;Ma, Young Kil;Kim, Jong Seok
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.43-48
    • /
    • 2020
  • Fe2O3 nanoparticles with the mixed structure of cubic and nanorod were synthesized by precipitation, hydrothermal, sol-gel method, etching process and heat treatment. Fe2O3/TiO2 core-shell (CS) of type Fe2O3@TiO2 composite was fabricated on a 20 nm nanolayer of TiO2 coated on the surface of Fe2O3 nanoparticles. Fe2O3/TiO2 yolk-shell (YS) composite was prepared by chemical etching and heat treatment of Fe2O3/TiO2 CS nanoparticles. Physical properties of Fe2O3, Fe2O3@TiO2 CS and Fe2O3@TiO2 YS nanoparticles were characterized by FE-SEM, HR-TEM and X-ray diffraction. The solar reflectance, commission internationale de l'Elcairage (CIE) color coordinate and heat shield temperatures of Fe2O3, CS and YS type Fe2O3@TiO2 pigments filled with poly acrylate (PA) paints were investigated by UV-Vis-NIR spectrometer and homemade heat shield temperature measuring device. The Fe2O3@TiO2 YS red pigment filled PA composite exhibited excellent near infrared light reflecting performance and also reduced the heat shield temperature of 13 ℃ than that of Fe2O3 filled counterparts.

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.

Cryptocaryoniasis of cultured flounder, Paralichthys olivaceus in low temperatures (저수온 양식 넙치 Paralichthys olivaceus의 Cryptocaryoniasis)

  • Ji, Bo-Young;Kim, Ki-Hong;Park, Soo-Il
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.97-111
    • /
    • 1997
  • In the winter of 1995, mass mortality occurred in cultured flounder, Paralichthys olivaceus in Gurongpo, Kyoungbuk, Korea. From the observations of moribund and dead fish, parasitic ciliates, which were shown as white spots to the naked eye, were considered to be involved in the mass mortality. From heavily infected flounders, histopathological, morphological and biological characterization of these ciliates were carried out. In the histological observation, many ciliates were found under the epithelia of gill filaments and skin, and caused hyperplasia of epithelial and mucus cells at the infected areas. The ciliates found on the body surface, fins and gills were very similar to Cryptocaryon irritans. However the ciliates showed two different patterns of reproductian, i.e., typical form(palintomy)and atypical form(budding plus multiple fission) at $16^{\circ}C$ of water temperature. The occurrence ratio between typical and atypical form was about 3:2. Tomitogenesis takes 8-14 days in the typical and 13-15 days in the atypical form. In the viability test at different temperatures and salinities, the typical form died below 30‰ at $12^{\circ}C$, below 20‰ at $16^{\circ}C$, below 15‰ at $20^{\circ}C$, and below 25‰ at $24^{\circ}C$, respectively. On the other hand, the atypical form died below 20‰ at $12^{\circ}C$, below 15‰ at 16-$20^{\circ}C$, and below 25‰ at $24^{\circ}C$, respectively. The results suggested that the atypical has better viability at low salinity than that of the typical at low temperatures. In the excystment time and success rates of excystment according to temperatures, the typical form showed 8 days, 30% at $12^{\circ}C$ : 6.5 days, 50%, at $16^{\circ}C$ : 5.5 days, 75% at $20^{\circ}C$ : and 7 days, 10% at $24^{\circ}C$, respectively. On the other hand, the atypical form showed 15.5 days at $12^{\circ}C$ : 14 days, 76.6% at $16^{\circ}C$ : 12 days, 72.2% at $20^{\circ}C$ : 10 days 31.6% at $24^{\circ}C$, respectively. The results suggested that the atypical form had longer excystment time than that of the typical form at any temperature and showed better stability at low temperatures.

  • PDF

Growth of $LiTaO_3$ and Fe doped-LiTaO3 single crystal as holographic storage material (홀로그래피 소자재료 $LiTaO_3$단결정 성장)

  • 김병국;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • The single crystal of the $LiTaO_3$has large electro-optic effects, so it is applied to optical switch, acousto-optic deflector, and optical memory device as hologram using photorefractive effect. In this study, optic-grade undoped $LiTaO_3$and Fe:LiTaO$LiTaO_3$single crystals were grown by the Czochralski method and optical transmission and absorption spectrums were measured in the wavelength of UV-VIS range. The curie temperature was determined with DSC and by measuring capacitance for the grown undoped crystal and ceramic powder samples of various Li/Ta ratio. In case of having a 48.6 mol% $Li_2O$ as a starting Li/Ta ratio, the results of concentration variations were below 0.01 mol% $Li_2O$ all over the crystal, so it was confirmed that $LiTaO_3$single crystals were grown under congruent melting composition having optical homogeneity. The curie temperature of the Fe:$LiTaO_3$crystal was increased with increased with increased doped Fe concentrations;by the ratio of $7.5^{\circ}C$ increase per Fe 0.1 wt%. Also, the optical transmittance was about 78 %, which was sufficient for optical device.

  • PDF

Seasonality of the Biological Activity Factors of the hard clam Meretrix lusoria in the Western Coast of Korea (한국 서해안 백합 Meretrix lusoria의 생물학적 활성요인의 계절성)

  • Song, Jae-Hee;Kim, Chi-Hong;Park, Sung-Woo;Yu, Jin-Ha;Jo, Yeong-Jo
    • Journal of Aquaculture
    • /
    • v.21 no.2
    • /
    • pp.111-122
    • /
    • 2008
  • This study was conducted to assess the usefulness of the temperature characteristics of the tidal flat sediments during low tide as a environmental factor, and burrowing behaviour, fatness, total hemocyte counts(THCs) and differential hemocyte counts(DHCs) of hard clam Meretrix lusoria as biological activity indices for the management of hard clam farms located in Taean(Chungnam province) and Gimje(Jeonbuk province) tidal flat in Korea. Temperature ranges of the sediment at 1cm depth during spring(March to May) and summer(June to August) in Taean(where the exposure time was about $5.5{\sim}6$ hours during low tide) were $8.7{\sim}26.8^{\circ}C\;and\;27.6{\sim}32.8^{\circ}C$, respectively. Even though there was no significant difference(P>0.05), temperatures of the surface sediment where submerged with remained seawater were generally higher than that of uncovered with seawater. Burrowing depths of normally digged hard clams were 0.9{\sim}3.6cm from March to October, 2002. In the field experiment performed at Taean farming ground covered with seawater, burrowing times of the clams under natural water temperatures were $41.6{\pm}10minutes$ in February and $5.4{\pm}1.3minutes$ in August, respectively, and these were influenced by water temperatures. Fatness of hard clams began to decrease from May(at Taean tidal flat) and June(at Gimje tidal flat), showed the lowest level in August and increased again from September. Total hemocytes counts in the hemolymph of the hard clams were decreased to the lowest level in July($24.7{\times}10^4cells/mL$, at Taean tidal flat) and August($28.2{\times}10^4cells/mL$, at Gimje tidal flat), and significantly increased again from September(at Taean tidal flat, P<0.01) and October(at Gimje tidal flat, P<0.001), respectively. We observed three types of hemocytes from the hemolymph of hard clams according to whether hemocytes retain the granules or not and the size of the granules. As a results, we could found that periodical monitoring of the sediment temperatures, clam burrowing behaviour and hemocyte parameters were very helpful for the management of hard clam farming.

Physical and Mechanical Properties on Ipseok-dae Columnar Joints of Mt. Mudeung National Park (무등산국립공원 입석대 주상절리대에 대한 물리역학적 특성)

  • Ko, Chin-Surk;Kim, Maruchan;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.383-392
    • /
    • 2016
  • This study is to evaluate the physical and mechanical properties on the Ipseok-dae columnar joints of Mt. Mudeung National Park. For these purposes, physical and mechanical properties as well as discontinuity property on the Mudeungsan tuff, measurement of vibration and local meteorology around columnar joints, and ground deformation by self-weight of columnar joints were examined. For the physical and mechanical properties, average values were respectively 0.65% for porosity, 2.69 for specific gravity, 2.68 g/cm3 for density, and 2411 m/s for primary velocity, 323 MPa for uniaxial compressive strength, 81 GPa Young's modulus, and 0.25 for Poisson's ratio. For the joint shear test, average values were respectively 3.15 GPa/m for normal stiffness, 0.38 GPa/m for shear stiffness, 0.50 MPa for cohesion, and 35° for internal friction angle. The JRC standard and JRC chart was in the range of 4~6, and 1~1.5, respectively. The rebound value Q of silver schmidt hammer was 57 (≒ 90 MPa). It corresponds 20% of the uniaxial compressive strength of intact rock. The maximum vibration value around the Ipseok=dae columnar joints was in the range of 0.57 PPV (mm/s)~2.35 PPV (mm/s). The local meteorology of surface temperature, air temperature, humidity, and wind on and around columnar joints appeared to have been greatly influenced the weather on the day of measurement. For the numerical analysis of ground deformation due to its self-weight of the Ipseok-dae columnar joints, the maximum displacement of the right ground shows when the ground distance is approximately 2 m, while drastically decreased by 2~4 m, thereafter was insignificant. The maximum displacement of the middle ground shows when the ground distance is approximately 0~2 m, while drastically decreased by 3~10 m, thereafter was insignificant. The maximum displacement of the left ground shows when the ground distance is approximately 5~6 m, while drastically decreased by 6~10 m, thereafter was insignificant.

Environmental Survey on the Cultivation Ground in the West Coast of Korea (서해연안의 양식장 환경조사 3. 부안 백합 양식장 환경)

  • LEE Jeong-Yeol;KIM Young-Gill
    • Journal of Aquaculture
    • /
    • v.4 no.2
    • /
    • pp.111-128
    • /
    • 1991
  • In puan area the environmental surveys were carried out at two farms of hard clam, Meretrix lusoria from April 1987 to November 1978 in order to know heather the farm environments could be rehabilitated for the cultivation of hard clam or not. The range of temperature of surface seawater was $10.7{\~}27.4^{\circ}C$, pH $7.6{\~}8.2$, salinity $22.3{\~}30.3$ ppt, COD $0.20{\~}4.71\;mg/{\ell}$, sulfide $0.04{\~}0.22\;{\mu}g-at./{\ell}$, suspended solid $34.8{\~}199.3\;mg/{\ell}$ chlorophyll a $3.71{\~}49.02\;mg/m^3$, TIN $2.01{\~}24.47\;{\mu}g-a5./{\ell}$, phosphate $0.60{\~}11.03\;{\mu}g-at./{\ell}$ and silicate $4.04{\~}476.36\;{\mu}g-at./{\ell}$. The range of temperature of substratum (bottom soil) was $14.2{\~}29.7^{\circ}C$, pH $8.3{\~}9.5$, water content of substratum was $0.28{\~}0.49\;mg/g$ dried mud, COD $2.80{\~}50.94\;mg/g$ dried mud, total organic matter $1.05{\~}1.97\%$ concentration of total Kjedhal nitrogen $31.9{\~}194.9\;{\mu}g./{\ell}$ dried mud, and sulfide $0.032{\~}0.133\;mg/g$ dried mud. Fine sand was dominant ranging over $92{\~}95\%$ and silt and clay was $2.8{\~}8.1\%$ of the composition of substratum. Some residual agricultural chemicals, ${\alpha},\;{\beta},\;{\gamma}$-BHC, heptachlor, heptachlor-epoxide, aldrin, DDE, DDT and dieldrin were detected in hard clams collected from Puan areas. Especialy, more chemical were detected during the period of rainfalls. From above results, it is considered that the hard clam frams were not yet recovered from deteriorated conditions for aquaculture.

  • PDF

Effect of the Nematode Sterilization of Nursery Medium using QRD Microwave in the Plant Factory (QRD 마이크로파를 이용한 식물공장용 배지의 멸균 효과)

  • Kim, Jin Hyun;Kim, Tae Wook;Lee, Keun Woo;Ha, Yu Shin;Lee, Jae Hyun;Kim, Kyung Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.100-107
    • /
    • 2013
  • Unlike general microwave, QRD (Quadratic Residue Diffusor) Microwave used in this study is known as a new technology that enhances the sterilization effect with low power because it is possible to induce the average sterilization by changing wavelength phase difference. Therefore, basic research was conducted on the function that could sterilize culture media for plant factory by using environmentally friendly and low energy consuming QRD Microwave. The results are as follows: It was confirmed that there was no external deformation in the polyurethane foam and rock wool medium when changing the microwave level between 2 and 8 kW in different water content of culture media. However, PDA solid media at 2 kW were not dissolved in 60 and 180 seconds. All of the media were dissolved in other processing. There was little difference in the microwave irradiation level and surface temperature of the strain according to the processing time between Bacillus sp. and Burkholderia sp. In the sterility test according to the microwave irradiation level and processing time, it was confirmed that both Bacillus sp. and Burkholderia sp. grew in the microwave level 2 kW regardless of time. In the microwave level 6 kW, all experimental groups except the processing of Burkholderia sp. for 60 seconds were sterilized, and all of Bacillus sp. was killed in the all experimental groups. In the microwave level 8 kW, it was confirmed that both Bacillus sp. and Burkholderia sp. were sterilized regardless of time. The temperature in microwave-processed media after contaminating strains to each medium was maintained at more than 100 in polyurethane foam and rock wool medium after 60 seconds. In general, it was shown that it was possible to sterilize after 60 seconds. Therefore, it is considered that Bacillus sp. and Burkholderia sp. which are the biggest problems in the plant factory can be adequately sterilized by QRD Microwave used in this study.

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF