• Title/Summary/Keyword: Korean song

Search Result 46,926, Processing Time 0.086 seconds

Effects of Gamma-Irradiation on the Sterilization of Primordial Germ Cells in Quail (메추리 원시생식세포 감소를 위한 감마선 조사의 효과)

  • Park, Kyung-Je;Kim, Tae-Min;Lee, Hyung-Chul;Jang, Hyun-Jun;Song, Gwon-Hwa;Han, Jae-Yong
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Quail is a very useful animal model for studying vertebrate development because of its small body size and unique reproductive traits. This species is also ideal model for producing germline chimeras via transferring exogenous primordial germ cells (PGCs) into the recipient embryo. To increase the contribution efficiency of donor PGCs into recipients' tissues, decreasing the population of endogenous PGCs has been rate-limiting factor. We therefore conducted this study to investigate if gamma ($\gamma$)-irradiation depletes endogenous PGCs in developing quail embryo. Firstly, freshly laid stage X quail embryos were irradiated with various output of $\gamma$-irradiation and its teratogenic effect on the embryo was evaluated. Although a dose-dependent increase in the number of embryo showing malformation was found as the output increased (0, 250, 500, 750, and 1,000 rads), only a maximum of 10.1% of embryos were abnormal in 1,000 rads. Immunocytochemical analysis using the QCR1 antibody, which is specific marker for quail PGCs, was conducted to analyze the effect of sterilization. As results, $\gamma$-rays at a dose-rate of 500 rads/73 sec onto undeveloped stage X embryo significantly reduced the number of germ cells to an average of 75.55 % and 82.03 % in male and female embryos, respectively. We conclude that $\gamma$-ray selectively targets PGCs while affects minimally to the somatic development in quail embryo. Our results will not only provide important data for germline chimera production but can be used for analyzing the effect of ionized rays on the differentiating germ cells in various stages during animal development.

Effects of Dietary Supplementation of Coffee Meal on Intestinal Enzyme Activity, Biochemical Profiles and Microbial Population in Broiler Chicks (커피박 첨가가 육계의 소장 효소 활성도, 생화학 지표 및 장내 미생물 균총에 미치는 영향)

  • Ko, Young-Hyun;Yun, Seo-Hyun;Song, Min-Hae;Kim, Se-Yun;Kim, Jong-Sun;Kim, Hyoun-Wook;Jang, In-Surk
    • Korean Journal of Poultry Science
    • /
    • v.41 no.2
    • /
    • pp.105-113
    • /
    • 2014
  • The current study was performed to investigate the effects of dietary supplementation of dried coffee meal (CM) on growth performance, intestinal and blood biochemical index, intestinal enzymes, and cecal microbial populations. A total of 162, 3-day-old male broiler chicks were randomly allocated into three dietary groups: control group (CON), basal diet added with 0.5% CM (CM I), and basal diet added with 1.0% CM (CM II). Dietary supplementation of CM did not change bird performance and the relative weight of intestinal mucosal tissues. The birds fed the diet supplemented with CM (0.5 and 1.0%) significantly decreased mucosal glucose concentration (P<0.05) without affecting blood glucose level compared with those fed control diet. The level of blood aspartate aminotransferase (AST) significantly increased in CM II group (P<0.05) without affecting ${\gamma}$-glutamyl transpeptidase (${\gamma}$-GTP) compared with that in the CON group. The specific activity of intestinal maltase, leucine aminopeptidase (LAP) and alkaline phosphatase (ALP) were not affected by dietary supplementation of CM, whereas sucrase activity in birds fed the diet supplemented with CM was decreased (P<0.05) compared to that in the control birds. The colony forming units (CFU) of E. coli in the cecum of CM-fed birds was significantly decreased (P<0.05) compared with that of control birds without changing the CFU of Lactobacillus. In conclusion, dietary supplementation of lower level of CM (0.5%) can be used as a beneficial feed resource without liver toxicity in broiler chicks.

The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT (PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구)

  • Do, Yong Ho;Song, Ho Jun;Lee, Hyung Jin;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.29-34
    • /
    • 2012
  • Purpose : Presently, hardwares and softwares for reducing radiation exposure are continually developed for PET/CT examination. Purpose of this study is to evaluate effectiveness of reducing radiation exposure dose of CT and SUV changes of PET when applied each kernel to ACCT (Attenuation Correction Computed Tomography) according to adopted IRIS (Iterative Reconstruction in Image Space) software. Materials and Methods : Biograph mCT (Siemens, Germany) was used as a PET/CT scanner. Using AAPM CT performance phantom, from standard (120 kVp, 100 mAs), 7 scans were conducted by reducing 15 mAs each. After image reconstruction by FBP (Filtered Back Projection) and IRIS, noise and spatial resolution were evaluated. The same method was applied to anthropomorphic chest phantom and acquired images were compared. NEMA IEC body phantom was used for SUV evaluation. Injected dose rate for hot sphere (hot) and background cylinder (BKG) were 1:8. CT dose condition (120 kVp, 50 mAs) was the same for each scan and PET scan durations were 1, 2, 3 and 4min. After scanning, each kernel of IRIS was applied to ACCT. And PET images were reconstructed by ACCT adopted IRIS for comparing SUV changes. Results : AAPM phantom test for noise evaluation, SD for FBP 100 mAs, IRIS 55 mAs were 8.8 and 8.9. FBP 85 mAs, IRIS 40 mAs were 9.5 and 9.7. FBP 70 mAs, IRIS 25 mAs were 11.9 and 11.1. Above mAs condition for FBP and IRIS, SD showed similar values. And for spatial resolution test, there was no significant difference. For chest phantom test, when applied the same mAs and kernel to both of FBP and IRIS, every applied kernels showed reduced noise. Lower mAs and higher kernel value showed higher noise reduction. There was no considerable difference only except for I70 very sharp kernel for SUV comparison using NEMA IEC body phantom. Conclusion : In this study, low mAs (55 mAs) applied IRIS and standard mAs (100 mAs) applied FBP showed similar noise. And only except for I70 kernel, there was no significant SUV changes. It is possible to reduce needless radiation exposure and acquire better image quality than FBP's through applying appropriate kernel of IRIS to PET/CT.

  • PDF

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

Usefulness of Blood Pool Half Body in Three Phase Bone Scan in Patients with R/O Reflex Symphathetic Dystrophy Syndrome (반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용)

  • Lee, Moo-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: Three phase bone scan was considered sensitive in Patients with Reflex Symphathetic Dystrophy Syndrome (RSDS). Generally, three phase bone scan in the RSDS patients shows increased uptake of one side extremity joint. But three phase bone scan has been performed with flow, blood pool and delayed scan. We performed blood pool half body scan in order to investigate its usefulness. Materials and Methods: From October 2007 to September 2009, three phase bone scan (flow, blood pool, half body blood pool, delayed) was performed after injection of 750 MBq of $^{99m}Tc$-DPD in diagnosed patients with RSDS (M:F=8:7, R:L=9:6). For quantitative analysis, we obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in the three phase images and compared with the count ratios of shoulders in half body blood pool and delayed images. Results: In flow images, right/left ratios were $1.09{\pm}0.53$. In blood pool images, right/left ratios were $1.13{\pm}0.47$ (hand), $1.08{\pm}0.26$ (shoulder). In delayed images, right/left ratios were $1.24{\pm}0.75$ (hand), $1.11{\pm}0.31$ (shoulder). As a result, Log of right/left counts of the others and that of shoulder blood pool image were correlated well with statistical significance (Spearman's R, p<0.005 SPSS for windows ver.12.0). Conclusion: Half body blood pool scan may be helpful in the diagnosis of patients with RSDS. Moreover, Half body blood pool scan reduced false negative and false positive rates. In order to improve agreement on interpretation of RSDS, Blood pool half body scan should be established as common criteria.

  • PDF

Seasonal Occurrences and Organic Agricultural Materials' Control Effect of Pseudococcus comstocki on 'Muscat of Alexandria' Organic Vineyard in Korea ('알렉산드리아' 유기 포도원에서 발생되는 가루깍지벌레의 계절적 조사 및 유기농업자재의 방제효과)

  • Song, Myung-Kyu;Park, Jae-Seong;Lee, Seok-Ho;Lee, Jae-Wung;Kim, Seung-Duck;Jeong, Chang-Won;Kim, Kyl-Ha;Park, Jong-Ho
    • Korean Journal of Organic Agriculture
    • /
    • v.25 no.4
    • /
    • pp.773-788
    • /
    • 2017
  • This study was carried out to investigate the damage patterns, the occurrence and migration time of Pseudococcus comstocki and in order to improve the control effect of organic agricultural materials (OAMs). The experiment was carried out at Okcheon's organic vineyard ($2,500m^2$, sandy loam, manure) where planted 8~9 year old 'Muscat of Alexandria' vines. The comstock mealybug's migration to grape clusters occurred from the middle of July, and produced eggs in the grape clusters from the end of July, and the density of the comstock mealybug was highest at $0.6cm^2$ in late August. The number and fruit damage of comstock mealybug in eco-friendly vineyards were higher than in conventional culture vineyard. And the marketability of green variety grape was more damaged from comstock mealybug than the black variety grape. Toxicities of 8 OAMs were evaluated to comstock mealybug at the recommended concentration. As a results, Lightyellow sophora and Derris extracts exhibited strong insecticidal activity with 100% mortality. When the Lightyellow sophora extract was uniformly distributed on the vine from early-July to mid-July, fruit damage reduction rate was 96.2% and 84.6%, respectively. So commercial grapes could be harvested. Therefore, it was considered to be effective to reduce fruit damage by controlling in early - late July (the green stage) when the comstock mealybug migrated to grape clusters in the vine greenhouse. In the future, it will be necessary to study the effect of external exposure time and momentum on the control of OAMs.

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets (돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가)

  • Song, In-Bae;Kim, Tae-Won;Lee, Hong-Gee;Kim, Myoung-Seok;Hwang, Youn-Hwan;Park, Byung-Kwon;Lim, Jong-Hwan;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome, a fourth generation cephalosporin, has been solely used for veterinary medicine and has a broad antibacterial spectrum against gram-negatives and gram-positives being very stable to ${\beta}$-lactamases. This study was conducted to evaluate the bioequivalence of two cefquinome 2.5% products in piglets. Plasma cefquinome concentrations were analyzed by liquid chromatography-mass spectrometry (LC/MS). Mean maximum concentration ($C_{max}$) of test product ($Cequus^{(R)}$) and reference product ($Cobactan^{(R)}$) were $4.34{\pm}0.58$ and $4.22{\pm}0.47{\mu}g/mL$, and mean area under the concentration time curve ($AUC_{0{\rightarrow}{\infty}}$) values were $10.43{\pm}1.96$ and $10.25{\pm}2.98{\mu}g{\cdot}h/mL$, respectively. The 90% confidence intervals for the ratio of $C_{max}$ (0.941-1.115), and $AUC_{0{\rightarrow}{\infty}}$ (0.927-1.172) values for the test and reference products were within the acceptable bioequivalence limit of 0.80-1.25. It is concluded that two commercial cefquinome injectable solutions are bioequivalent in their extent of drug absorption in piglets.