• Title/Summary/Keyword: Korean medical hospital

Search Result 17,857, Processing Time 0.054 seconds

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Analysis of characteristics affecting the score-groups by supervisor and subordinate rating (하향평가와 상향평가 결과에 영향을 미치는 특성 분석)

  • Shin Ki Soo;Cho Woo Hyun;Park Young Yo;Jung Sang Huyk;Lee Hye Jean
    • Health Policy and Management
    • /
    • v.15 no.1
    • /
    • pp.97-117
    • /
    • 2005
  • This study was designed to compare the differences m results of supervisor and subordinate rating. Data was collected from personnel evaluation and subordinate rating results for middle managers(n=68) in hospital from 3rd January to 20th March in 2004. Supervisor rating consisted of performance, ability and attitude evaluation. Subordinate rating consisted of leadership, ability and attitude evaluation. Collected data included sociodemographic characteristics, work department, work level, years of work, years at present level and whether working in a patient serving department. The difference of standardized supervisor and subordinate rating score was used to define groups as 'higher in supervisor rating group'. Groups were defined in total score, ability score and attitude score. Main results were as follows: 1. In total score, sectional chiefs were apt to be 'higher in subordinate rating group' while chief clerks were apt to be 'similar group' or 'higher in supervisor rating group'. Staffs in patient serving department were likely to be 'higher in supervisor rating group' and staffs in non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 2. In ability score, there were no statistically significant differences in age, sex, years of education, work department, work level, years of work and whether working in a patient serving department among 'higher in supervisor rating group', 'similar group' and 'higher in subordinate rating group'. 3. In attitude score, staffs in the department of medical affairs and the department of administration were apt to be 'higher in subordinate rating group'. Staffs in the department of nursing were apt to be 'higher in supervisor rating group'. Staffs in a patient serving department were likely to be 'higher in supervisor rating group' and staffs in a non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 4. Logistic analysis about total score showed that sectional chiefs had higher Odds Ratio(OR) to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. Both these results were statistically significant. 5. Logistic analysis about ability score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. These results were not statistically significant. 6. Logistic analysis about total score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group', but the difference was not statistically significant. Staffs in a non-patient serving department had significantly higher OR to be in 'higher in subordinate rating group'. In conclusion, there is no clear superiority between supervisor and subordinate rating in personnel evaluation. It would be better to use a mixed model. It's also suggested to use an intervening rate of application or scores considering work levels and work department in personnel evaluation. These results would be helpful for hospitals planning a supervisor and subordinate rating system for personnel evaluation.

Effects of Growth Hormone Therapy in Children with Idiopathic Short Stature (특발성 저신장증 소아에서 성장호르몬의 치료효과)

  • Lee, Kyong A;Han, Heon Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.865-870
    • /
    • 2005
  • Purpose : The use of growth hormone(GH) to promote growth in normal short children without classical GH deficiency is controversial. Numerous foreign studies have shown the effects of GH therapy in children with idiopathic short stature(ISS) whereas few has been interested in Korea. Therefore, this study is designed to investigate the effects of GH therapy on ISS by observing correlations and changes among various growth parameters such as, insulin-like growth factor-I(IGF-I) and insulin-like growth factor binding protein-3(IGFBP-3). Methods : This study was conducted retrospectively with 15 children with ISS in Chungbuk National University Hospital in Korea. Mean age was $11.44{\pm}2.81$ and the children were treated with 0.66 IU/kg/wk dosage of GH for 1 or 2 years. Also, the growth parameters before and after the GH therapy were observed. Results : Height standard deviation score(HT-SDS) was increased from $-1.85{\pm}0.70$ to $-1.58{\pm}0.56$ at 1 year and to $-1.21{\pm}0.37$ at 2 years after GH therapy. Predicted adult height standard deviation score(PAH-SDS) was also increased from $-2.10{\pm}0.52$ to $-1.67{\pm}0.59$ at 1 year, and to $-0.96{\pm}0.60$ at 2 years. Serum IGF-I and IGFBP-3 levels were significantly increased after 1 year and marginally increased after 2 years of GH therapy. Conclusion : It is concluded that GH therapy has growth promoting effect. The significant increase in IGF-I and IGFBP-3 levels during the GH therapy suggests that IGF-I and IGFBP-3 are useful predictors of response to the use of GH therapy. It is expected that larger patient samples would provide more reliable information about the effect of GH therapy.

Clinical Findings of Mycoplasma Pneumonia in Children, from 1998 to 2003 (최근 6년간(1998-2003) 소아 Mycoplasma 폐렴의 임상 양상)

  • Kim, Ji-Hyun;Chae, Soo Ahn;Lee, Dong-Keun
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.969-975
    • /
    • 2005
  • Purpose : We performed a study of clinical findings of Mycoplasma Pneumonia in children, to know differences between recent clinical manifestations of Mycoplasma pneumonia and previous studies. Methods : The subjects of this study were 393 children who were diagnosed as Mycoplasma pneumonia with high titers of Mycoplasma antibody(${\geq}1$ : 160) or fourfold rises of Mycoplasma antibody at Chung Ang University Hospital from January 1998 to December 2003. We practiced a retrospective study on the clinical manifestations of Mycoplasma pneumonia based on their medical records. Results : Male to female ratio was 1.06 to 1 and mean age was $4.32{\pm}2.94years$. The highest incidence was in the age of 2 to 3 years(18.6 percent). Most frequent months were October, and November in 2000, April in 2002, and October and, December in 2003. Twenty six point seven percent showed allergic diseases. Second degree relatives of 10.7 percent patients had allergic diseases. Forty three point three percent were admitted before this admission for pneumonia. Allergic tests were positive in 65.7 percent. Cough, and sputum were the most common symptoms and abdominal pain, and vomiting were the most frequent extrapulmonary symptoms. Atelectasis and pleural effusion were seen in 2.5 percent and 1.8 percent. Infiltrations were more common on the right side. Titers of each simultaneous test for cold agglutinin and mycoplasma antibody were not in proportion to each other (P=0.163). Conclusion : The onset age of mycoplasma pneumonia was found to be lower than it used to be. More patients had a past medical history or a family history of allergic disease, and more wheezing was heard and associated with recurrent pneumonia.

Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs (패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과)

  • Chang, Yun Sil;Ko, Sun Young;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.777-783
    • /
    • 2003
  • Purpose : The aim of this study was to evaluate the effect of inhaled nitric oxide(iNO) on gas exchange, hemodynamics and pulmonary inflammation in newborn piglets with E. coli induced septic lung. Methods : Twenty three instrumented and ventilated piglets were randomized into three groups : CON(n=6), PCON(n=9), and PNO(n=8). In the piglets of the PCON and PNO groups, E. coli septic lung was induced by endotracheal instillation of E. coli. Ten ppm iNO was given continuously in the PNO group after endotracheal instillation of E. coli. All animals were mechanically ventilated for six hour with a peak inspiratory pressure of 30 $cmH_2O$, frequency of 25 breaths/min, $FiO_2$ 1.0 and a positive end-expiratory pressure of 4 $cmH_2O$. All measurements were made at one hour intervals during the experiment. At the end of the experiment, lung tissue was harvested for the analysis of myeloperoxidase activity, indicative of lung inflammation. Results : All piglets with pulmonary instillation of E. coli developed E. coli sepsis. Piglets in the PCON group developed progresseve pulmonry hypertension, hypoxemia and hypercarbia compared to the CON group due to increased pulmonary vascular resistance, intrapulmonary shunt fraction and physiologic dead space fraction. iNO did not reverse pulmonary hypertension in the PNO group. However iNO significantly improved oxygenation, which was attributed to marked improvement of venous admixture and partial attenuation of increase in dead space fraction. Increased myeloperoxidase activity in PCON compared to CON was significantly attenuated in PNO. Conclusion : iNO improves oxygenation and lung inflammation in newborn piglets with E. coli induced septic lung.

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Expression of Matrix Metalloproteinase-2 and Tissue Inhibitor of Metalloproteinase-2 in Radiation Exposed Small Intestinal Mucosa of the Rat (방사선조사를 받은 흰쥐 소장 점막의 손상과 재생과정 중 금속단백효소 및 억제자의 발현)

  • Kwag, Hyon-Joo;Lee, Kyoung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.66-74
    • /
    • 2003
  • Purpose : The matrix metalloprotelnases (MMPs) are a family of enzymes whose main function is the degradation of the extracellular matrix. Several studies have revealed that MMPs and TIMPS are related to the wound heating process and in photoaging caused by ultraviolet Irradiation. However, the expressions of MMP and TIMP after irradiation have not, to the best of our knowledge, been studied. This study investigates the expressions of MMP-2 and TIMP-2 in rat Intestinal mucosa following irradiation. Materials and Methods : The entire abdomen of Sprague-Dawley rats was irradiated using a single dose method. The rats were sacrificed on day 1, 2, 3, 5, 7 and 14 following irradiation. Histopathological observations were made using hematoxilin & eosin staining. The expressions of MMP-2 and TIMP-2 were examined using immunohistochemistry, Irnrnunoblotting and ELISA. Results : Radiation induced damage associated with atrophic villi, and infiltration of inflammatory cell was observed from the first postirradiation day, and severe tissue damage was observed on the second and the third postirradiation days. An increase in mitosis and the number of regenerating crypts, as evidence of regeneration, were most noticeable on the fifth postirradiation day. From the immunohistochemlstry, the MMP-2 expression was observed from the first postirradiation day, but was most conspicuous on the third and the fifth postirradiation days. The TIMP-2 expression was most conspicuous on the fifth postirradiation day. From the irnrnunoblotting, the MMP-2 expression was strongly positive on the third postirradlatlon day, and that of TIMP-2 showed a strong positive response on the fifth postirradiation day. In ELISA tests, the expressions of MMP-2 and TIMP-2 were increased in the postirradiation groups compared to those of the normal controls, and showed a maximum increase on the fifth postirradiatlon day. These results were statistically significant. Conclusion : The expressions of MMP-2 and TIMP-2 were increased in the intestinal mucosa of the rats following irradiation, and these results correlated with the histopathological findings, such as tissue damage and regeneration. Therefore, this study suggests that MMP-2 and TIMP-2 play roles in the mechanisms of radiation-induced damage and regeneration of intestinal mucosa of rats.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.