• Title/Summary/Keyword: Korean margin

Search Result 3,450, Processing Time 0.026 seconds

SONOGRAPHIC FINDING OF MAXILLOFACIAL MASS (악안면 종창에 대한 초음파 소견)

  • Kim, Hyoun-Tae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.1_2
    • /
    • pp.143-145
    • /
    • 1992
  • Fourteen masses in the maxillofacial areas which are not diagnosised simply as abscess were studied with ultrasound to evaluate its diagnostic role. Benign mass showed homogeneous echopattern with smooth margin and cyst a few internal echo with smooth margin. But malignant mass showed irregular margin, inhomogeneous echotexture and deep extension. Ultrasonography considered as an initial noninvasive imaging modality for the evaluation of maxillofacial masses.

  • PDF

The Optimal VAR Planning Considering Voltage Stability Margin (전압안정도여유를 고려한 무효전력원 배분계획)

  • Song, Kil-Yeong;Choi, Sang-Kyu;NamKung, Jae-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.33-35
    • /
    • 1993
  • This paper presents a new optimal VAR planning algorithm considering voltage stability margin. The characteristic of this method is to make it possible to formulate VAR planning for the dual purpose of maintaining voltage profiles within specified limits, and increasing the voltage stability margin of anticipated operating conditions with respect to voltage collapse. The IEEE-30 bus system is used to demonstrate the capability of the proposed algorithm.

  • PDF

Crustal Structure of the Continental Margin of Korea in the East Sea: Results From Deep Seismic Sounding (한반도의 동해 대륙주변부의 지각구조 : 심부 탄성파탐사결과)

  • Kim Han-Joon;Cho Hyun-Moo;Jou Hyeong-Tae;Hong Jong-Kuk;Yoo Hai-Soo;Baag Chang-Eop
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.1
    • /
    • pp.40-52
    • /
    • 2003
  • Despite the various opening models of the southwestern part of the East Sea (Japan Sea) between the Korean Peninsula and the Japan Arc, the continental margin of the Korean Peninsula remains unknown in crustal structure. As a result, continental rifting and subsequent seafloor spreading processes to explain the opening of the East Sea have not been adequately addressed. We investigated crustal and sedimentary velocity structures across the Korean margin into the adjacent Ulleung Basin from multichannel seismic reflection and ocean bottom seismometer data. The Ulleung Basin shows crustal velocity structure typical of oceanic although its crustal thickness of about 10 km is greater than normal. The continental margin documents rapid transition from continental to oceanic crust, exhibiting a remarkable decrease in crustal thickness accompanied by shallowing of Moho over a distance of about 50 km. The crustal model of the margin is characterized by a high-velocity (up to 7.4 km/s) lower crustal (HVLC) layer that is thicker than 10 km under the slope base and pinches out seawards. The HVLC layer is interpreted as magmatic underplating emplaced during continental rifting In response to high upper mantle temperature. The acoustic basement of the slope base shows an igneous stratigraphy developed by massive volcanic eruption. These features suggest that the evolution of the Korean margin can be explained by the processes occurring at volcanic rifted margins. Global earthquake tomography supports our interpretation by defining the abnormally hot upper mantle across the Korean margin and in the Ulleung Basin.

Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study

  • Cetik, Sibel;Bahrami, Babak;Fossoyeux, Ines;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.208-216
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the precision of optical impression (Trios, 3Shape) versus that of conventional impression (Imprint IV, 3M-ESPE) with three different margins (shoulder, chamfer, and knife-edge) on Frasaco teeth. MATERIALS AND METHODS. The sample comprised of 60 zirconia half-crowns, divided into six groups according to the type of impression and margin. Scanning electron microscopy enabled us to analyze the gap between the zirconia crowns and the Frasaco teeth, using ImageJ software, based on eight reproducible and standardized measuring points. RESULTS. No statistically significant difference was found between conventional impressions and optical impressions, except for two of the eight points. A statistically significant difference was observed between the three margin types; the chamfer and knife-edge finishing lines appeared to offer better adaptation results than the shoulder margin. CONCLUSION. Zirconia crowns created from optical impression and those created from conventional impression present similar adaptation. While offering identical results, the former have many advantages. In view of our findings, we believe the chamfer margin should be favored.

Primary Cutaneous Mucinous Carcinoma Treated with Narrow Surgical Margin

  • Choi, Jin-Hee;Kim, Seung Chan;Kim, Jiye;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.158-161
    • /
    • 2016
  • Primary cutaneous mucinous carcinoma (PCMC) is a rare malignant tumor of eccrine origin. Clinically, the carcinoma presents as a solitary, slow growing, and painless nodule. For this reason, this tumor is often considered to be a benign mass in the preoperative setting. The lesion is, however, malignant in nature and has a tendency for local recurrence and infrequent metastasis. Wide local excision is the treatment of choice. However, few reports exist with information regarding surgical margins and clinical outcomes. Herein, we report a case of PCMC excised with a narrow surgical margin and review the relevant literature. A 49-year-old man presented with a small cutaneous nodule of the right cheek. The mass was excised without any margin, but pathologic examination revealed histology of mucinous carcinoma. Because of this, the operative site was re-excised with a 5-mm margin, and the wound was closed using a V-Y advancement flap. Systemic work-up did not reveal other potential metastatic primary, for a final diagnosis of PCMC. We report this case of PCMC, treated with relatively narrow margin in a patient with good prognostic factors.

A Study of Margin Fitness in Metal-bond Porcelain Crown II (도재용착주조관 변연의 적합성에 관한 연구 II)

  • Lee, In-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.27-30
    • /
    • 1983
  • This study was undertaken to know the difference that margin fittness in metal bond porcelain crown. When we use porcelain precious metal and non-precious metal as porcelain-fused metal, the results were as following. 1. The precious metal was showed best result in margin fittness and shade. 2. The non-precious metals were showed good results, especially Gemini II was excellent, but that was not good than precious metal. 3. 10k. gold plating on non-precious metal cap showed same result as nonprecious metal in margin fittness, and not good in shade. 4. When we use the non-precious metals at upper part of crown, and using precious metal in 2mm cervical portion, the margin fittness were very good, and the results same as full veneer precious metal.

  • PDF

A Study on the Suitability of Cervical Margin According to Die Materials Used in Crown Prosthesis (치관보철물 제작시 사용되는 치형 재료에 따른 치경부 변인의 적합성에 관한 연구)

  • Lee, In-Kyu;Choi, Un-Jae;Chung, Hee-Sun
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.5-12
    • /
    • 2000
  • The gaps between the die margin worked and the casting body were measured with an optical microscope and compared after making crown prosthetic materials using three kinds of die material - dental stone, extra hard stone, epoxy resin - used in crown prosthesis. The results are as follows : 1. All the gaps between the cast cervical margin and the casting bodies were relatively good regardless of die materials used with the gaps under $50{\mu}m$, the allowable limit. 2. The cervical margin suitability of epoxy resin die was the highest among the three kinds of die material with the suitability value of $30.28{\pm}12.67$. 3. Among the four surfaces(buccal, lingual, mesial, distal) of all the casting bodies, buccal surface was the highest in the cervical margin suitability with the value of $25.93{\pm}15.51$.

  • PDF

A Protection Ratio with Composite Fade Margin for Detailed Frequency Coordination in Microwave Relay System Network

  • Suh, Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.2
    • /
    • pp.83-90
    • /
    • 2007
  • In this paper, the formulation of the protection ratio based upon a composite fade margin and availability is newly presented for the detailed planning of frequency coordination in the microwave relay system network, and computed results for co-channel and adjacent channel protection ratios are illustrated over an actual system with 6.2 GHz. It is shown that the protection ratio to assure a quality of service can be expressed in terms of the composite fade margin, noise-to-interference ratio, net filter discrimination, and system parameters. In addition, the net filter discrimination, depending upon the transmitter spectrum mask and the overall receiver filter characteristic, has been examined to investigate the effect of the adjacent channel protection ratio caused by the adjacent channel interference. Regarding simulated results for 6.2 GHz, 60 km, 64-QAM, and N/I=6 dB at the bit error rate of $10^{-6}$, composite fade margin and co-channel protection ratio yield 25.14 and 50.3 dB, respectively. Also, the net filter discrimination of 26.5 dB and the adjacent channel protection ratio of 23.8 dB are obtained at the first adjacent channel of 30 MHz. The proposed method provides some merits in view of a comprehensive and practical application with more detailed and various system parameters needed to access the criteria for making the proper frequency coordination.

Geometrical Effects of an Active Casing Treatment on Aerodynamic Performance of a Centrifugal Compressor (능동형 케이싱 트리트먼트의 형상 변화가 원심압축기의 공력성능에 미치는 영향)

  • Ma, Sang-Bum;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.5-12
    • /
    • 2016
  • In this study, a parametric study on a cavity as casing treatment of a centrifugal compressor has been conducted using three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model. Two kinds of cavity were applied at choke and surge conditions, respectively, in this work. Inlet and outlet port widths, angle of outlet port, and length of cavity were chosen as the geometric parameters and investigated to find their effects on the aerodynamic performances such as adiabatic efficiency at design mass flow rate and stall margin of the centrifugal compressor. It was found that the aerodynamic performances of the centrifugal compressor were affected considerably by the four geometric parameters. The adiabatic efficiency was hardly changed by the geometric parameters, excepts for the angle of outlet port. With an increase in the angle of outlet port, the adiabatic efficiency and the stall margin decreased. The stall margin was more sensitive to the outlet port width than to the other geometric parameters. And, with a decrease in the outlet port width, the stall margin increased by 2% compared to that of the reference.

MARGINAL LEAKAGE OF CLASS 2 GLASS-IONOMER CEMENT RESTORATIONS NOT INVOLVING OCCLUSAL SURFACE (교합면을 포함하지 않는 2급 글래스 아이오노머 시멘트 수복물의 변연누출)

  • Lee, Young-Ran;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.288-295
    • /
    • 1998
  • The microleakage of direct-access Class 2 restorations was evaluated. Cavities were prepared at mesial and distal proximal enamel surfaces of 20 extracted human molars through buccal window. Prepared cavities were filled with Ketac-Fil, Ketac-Silver, and Fuji II LC, following manufacturer's instructions. 4 specimens of each restorations were made through sectioning 1/4 of bucco-lingual length mesio-distally after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and imerging 0.5% basic-fuchsin dye solution. Leakage at both occlusal and gingival margin of each specimen was scored 0 to 3 with stereomicroscope. The results were as follows: 1. At occlusal margin, leakage in Ketac-Fil group was more than Ketac-Silver and Fuji II LC group (ANOVA p<0.05) and there was no significant difference between Ketac-Silver and Fuji II LC group(p>0.05), and at gingival margin, there was no significant difference amang materials (p>0.05). 2. Occlusal margin leaked more than gingival margin in Ketac-Silver and Fuji II LC group (t-test p<0.05). 3. Leakage was different according to bucco-lingual location in Ketac-Fil and Fuji II LC group, and lingaul specimen exhibited more leakage(ANOVA p<0.05).

  • PDF