• Title/Summary/Keyword: Korean image

Search Result 29,556, Processing Time 0.064 seconds

Results of Stereotactic Radiosurgerv with Linear Accelerator for Intracranial Arteriovenous Malformation (두개강내 동정맥기형에서 선형가속기를 이용한 방사선수술의 결과)

  • Lee Kang Kyoo;Park Kyung Ran;Lee Jong Young;Lee Yong Ha
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.215-224
    • /
    • 1997
  • Purpose : Stereotactic radiosurgery with external beam irradiation successfully obliterates carefully selected intracranial arteriovenous malformation (AVM) . We Present clinical and radiological long term results after treatment with a single high dose irradiation using a linear accelerator. Materials and Methods : Rrom January 1991 to June 1994, fifteen patients with intracranial AVM were treated in our hospital with the stereotactic radiosurgery using a linear accelerator. The radiation was delivered using a 6 MV linear accelerator. The prescribed doses at the isocenter varied from 1800 to 2500cGy (median : 2000cGy) and were given as a sin91e fraction. The radiation doses at the periphery of the lesion typically corresponded to the 80-90% isodose line. In 14 patients, complete clinical and/or radiological follow-up examination were available. Results : Angiography was available in 13 patients with a follow-up Period from 18 months to 27 months. Of 13 patients, the overall complete obliteration rate was 92.3% (12 patients). This incidence did not correlate with lesion size. Seizure, headache and progressive neurologic deficit were complete recovered. One Patient experienced hemorrhage at 2 months after treatment. One patient developed radiation induced brain edema in the white matter surrounding nidus at 16 months after treatment and showed complete resolution of the edema in MR image obtained at 27 months after treatment. After a follow-up period of up to 6 years, no radiation induced severe late complications occurred. Conclusion : We conclude that stereotactic radiosurgery using a linear accelerator is an effective and safe therapy for symptomatic and surgically inaccessible intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic radiosurgery.

  • PDF

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.

A research on remodelling of the laboratory of S high school of broadcasting for converting into specialized one in the section of broadcasting industry (방송 산업 분야의 특성화고등학교로 전환을 위한 S방송고등학교의 실험.실습실 리모델링에 관한 연구)

  • Oh, Seung-gyun;Lee, Myung-Eui;Lee, Yong-soon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.87-112
    • /
    • 2009
  • The aim of this research is to suggest the model of reconstruction and remodelling of S high school of broadcast for converting into a specialized one in the section of broadcast industry. The method of reconstruction of the laboratories by each department is as follows. First, the names of laboratories, ground plans, and perspective drawings are designed according to the principle of constructionism. Second, each department is recommended to install 7 laboratories. For the department of broadcasting facilities, a laboratory of processing broadcasting machines, a laboratory of broadcasting machines, and a laboratory of screen picture machines are needed. For the department of broadcasting, electricity, and communication, a laboratory of image and sound edition, a laboratory of broadcasting and communication, a laboratory of broadcasting system, and a laboratory of stage illumination. For the department of broadcasting stage construction, a laboratory of broadcasting stage building, a laboratory of broadcasting stage design, a laboratory of broadcasting stage decoration and etc. Third, an office room is designed by department in the form of seminar room and places for practice is formed by department to be a laboratory. Fourth, a room for industrial-educational cooperation is installed by department, by which education of industrial-educational cooperation is carried out harmoniously. And one example of a remodeled laboratory by one department is shown with laboratory name, ground plan, perspective drawing, and running method. Especially employment of teachers working both school and business, professional club which is concerned with broadcasting technique, and attraction of enterprise in school is suggested as important elements to manage broadcasting laboratories efficiently. Finally, it is desirable for us to attract private capital, that is, Build-Transfer-Lease(BTL) because much budget is required for purchasing the broadcasting equipments and remodelling the laboratories to succeed as specialized high school on broadcasting section.

Effect a Presentation Product has on the Repurchase Action (증정상품이 소비자의 재구매행동에 미치는 영향)

  • Yun, Gi-Seon;Kim, Hong
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.375-404
    • /
    • 2007
  • When we look into the market economy of our country recently, we learn that the mind of consumption after IMF crisis is very shrunk and the market is led into a serious slump of consumption. For an approach to survive the contraction of the market and the market competition, enterprises command a variety of sales promotion strategy, out of which presentation is a sales promotion strategy to give the same product. The price-discounted strategy through the provision of donation commodity may induce the temporarily-discounted commodity not to be sold to the consumers or make a damage of the images of the brand, or arouse the price war against other companies, or lower the sense of the quality of the commodity. Therefore, it is necessary for a company to meet the end users' demand and also maintain the evaluation of the quality on the consumers' products highly. Therefore, in this study, we have attempted to study and analyze the consumers' satisfaction level and reliability on the donation goods in order to suggest the orientation of the presentation promotion strategy in accordance with the changes of the sales market. In addition, we tried to understand how the recognition, consumers' satisfaction level and reliability on the presentation goods had on the repurchase. With such objectives in this study, we could make an analogy of the following significance and suggestion of study. Firstly, in order to survive a serious competition market, enterprises must execute the product presentation along with diverse events instead of commanding the sales promotion strategy through a simple product presentation. This strategy can be an alternative to lower the danger a person-to-person product presentation may bring about. That is to say, we shall not lower the quality and value of the products but enhance a new image to customers through a product donation occasion together with an event as a new marketing pioneering method. Secondly, during the period of the current economic depression, if a company provides the consumers with an opportunity free of charge through the present special event period and the practical events, it will affect the advertising effect of the goods, the introduction of the customers and customers' repurchase. For this purpose, the company has to heighten customers' preferences by selecting the items customers are liable to prefer and closely analyze the consumer's response and market for such an objective. Thirdly, with the internet age, as the market has a tendency to increase in the number of consumers who do shopping in the internet, the marketing strategy has to build up the strategy of the presentation product instead of a simple offline strategy. For example, a company shall have to draw attention or attraction from end users who intend to do shopping through the online by a product planning expo or a presentation product corner. Fourthly, the excessive sale promotion strategy of presentation products may bring about even a reverse effect on the value of the goods or consumers' attitude as seen above. Therefore, a company has to relay 'the value as to the price' to the consumers instead of the sales promotion strategy of donation products just for a temporary sales volume. Conclusively, even if we put the value with a reasonable price through the presentation product strategy in the past, we shall have construct the strategy by providing some plus factors in the price such as the provision of the upgraded products or services instead of just presentation, or the invitation of the events related to diverse events or culture arts from now on.

  • PDF

Measurements of Carotid Intima, Media, and Intima-media Thickness and Their Clinical Importance (경동맥의 내막, 중막, 내중막 두께 분리측정 및 임상적 중요성)

  • Kim Wuon-Shik;Jeong Hwan-Taek;No Ki-Yong;Bae Jang-Ho
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.207-213
    • /
    • 2005
  • The severity of carotid Intima-media thickness (IMT) is an Independent predictor of atherosclerosis which causes transient cerebral ischemia, stroke, and coronary events such as myocardial Infarction. The IMT consists of Intima thickness (IT) and media thickness (MT). However, the Individual clinical significance of IT and MT has not been well studied. We devised a method of measuring IT, MT, and IMT using B-mode ultrasound Image processing technique for the diagnosis of atherosclerosis. To inspect the clinical significance of IT, MT, and IMT, one hundred forty-four consecutive patients (mean age; 57 years old, 72 males) were underwent common carotid artery scanning using high-resolution ultrasound. Results showed that, the IT (p<0.05), MT (p<0.05) as well as IMT (p<0.01) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hyperiension showed significantly thicker IT (p<0.01), MT (p<0.001), and IMT (p<0.001). However, only IT was thicker in patients with smoking (p<0.01). The IT (r=0.374, p=0.001), MT (r=0.433, p=0.000), and IMT (r=0.479, p=0.000) showed positive correlation with age. The coefficients of determination ($r^2$) were estimated to be $92.4\%$ for IMT and MT, $49.1\%$ for IMT and IT, and $27.4\%$ for IT and MT. This result suggests that the Intima layer of the carotid artery has a different physiology with the media layer.

  • PDF

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

Transient Splenial Lesions in the Splenium of Corpus Callosum in Seven Patients: MR Findings and Clinical Correlations (뇌량 팽대의 일과성 병변: 7명의 환자에서의 자기공명 영상소견과 임상 양상의 연관성)

  • Park, Ju Young;Lee, In Ho;Song, Chang June;Hwang, Hee Youn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The purpose of this study is to correlate the imaging findings and the clinical findings in patients with transient splenial lesions (TSL). Materials and Methods: Total of 7 patients (M: F = 4: 3; age range 11 - 38 years, mean age 25.5 years) were studied between November 2006 and April 2011. The MRI findings and clinical findings in all patients were retrospectively reviewed. The location, MR signal intensity, restricted diffusion, enhancement pattern and reversibility from the follow up images were reviewed. Clinical features were reviewed with respect to the presented symptoms, signs, treatment and outcome. Results: The lesions were located in the splenium of corpus callosum in all patients. All lesions showed high signal intensity on diffusion weighted imaging (DWI), and six patients showed restricted diffusion on the apparent diffusion coefficient (ADC) map. ADC map was not available in one patient. All lesions (n = 7) showed high signal intensity on the T2 weighted image (T2WI). Five of the patients (71.4%) with follow up images (range 7 - 34 days) showed complete resolution of focal high signal intensity on DWI, with recovery of ADC values as well as T2WI. After contrast media administration, none of the lesions showed any enhancements. All lesions with various etiologies including TB medication were developed in younger age patients and showed reversibility after the acceptable period of minimum 7 days with conservative treatment. Conclusion: All TSL showed nonspecific imaging findings, including restricted diffusion on DWI and ADC map on the initial images. However, reversibility of the lesions and the young age preference can be a characteristic finding of TSL with acceptable period of minimum 7 days. In addition, to keep it in mind that various etiologies including TB medication may cause TSL, is important for radiologists as well as clinicians.

Hemodynamic Outcome of Successful Bypass Surgery in Patients with Atherosclerotic Cerebrovascular Disease: A study with Acetazolamide and $^{99m}Tc-ECD$ SPECT (죽상경화성 뇌혈관질환 환자에서 성공적인 EC/IC 우회술 후 혈류역학적 변화: 기저/아세타졸아미드 SPECT를 이용한 연구)

  • Eo, Jae-Seon;Oh, Chang-Wan;Kim, Yu-Kyeong;Park, Eun-Kyung;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.293-301
    • /
    • 2006
  • Purpose: The aim of the study was to evaluate the hemodynamic changes after successful bypass surgery in patients with atherosclerotic stenosis in ICA using $^{99m}Tc-ECD$ SPECT. Materials and Methods: Fourteen patients (M:F=8:6, mean age; $60{\pm}9$ years) who underwent STA-MCA anastomosis for unilateral atherosclerotic cerebrovascular disease were enrolled. $^{99m}Tc-ECD$ basal/acetazolamide perfusion SPECT studies were performed before, 10 days and 6 months after bypass surgery. Perfusion reserve was defined as the % changes after acetazolamide over rest image. Regional cerebral blood flow and perfusion reserve were compared preoperative, early-postoperative and late-postoperative scans. Results: The mean resting perfusion and decrease in perfusion reserve in affected ICA territory on preoperative scan was $52.4{\pm}3.5\;and\;-7.9{\pm}4.7%$, respectively. The resting perfusion was significantly improved after surgery on early-postoperative scan (mean $53.7{\pm}2.7$) and late-postoperative scan (mean $53.3{\pm}2.5$) compared with preoperative images (p<0.05, respectively). Resting perfusion did not showed further improvement on late-postoperative scan compared with early-postoperative scan. The perfusion reserve was $-3.7{\pm}2.6%$ on early-postoperative scan, and $-1.6{\pm}2.3%$ on late-postoperative scan, which was significantly improved after surgery. Additionally, further improvement of perfusion reserved as observed on late-postoperative scan (p<0.05). While, in the unaffected ICA territory, no significant changes in the resting perfusion and perfusion reserve was observed. Conclusion: The improvement of resting perfusion and perfusion reserve in early-postoperative scan reflects the immediate restoration of the cerebral blood flow by bypass surgery. In contrasts, further improvement of perfusion reserve showing on late-postoperative scan may indicate a good collateral development after surgery, which may indicate good surgical outcome after surgery.

R-lambda Model based Rate Control for GOP Parallel Coding in A Real-Time HEVC Software Encoder (HEVC 실시간 소프트웨어 인코더에서 GOP 병렬 부호화를 지원하는 R-lambda 모델 기반의 율 제어 방법)

  • Kim, Dae-Eun;Chang, Yongjun;Kim, Munchurl;Lim, Woong;Kim, Hui Yong;Seok, Jin Wook
    • Journal of Broadcast Engineering
    • /
    • v.22 no.2
    • /
    • pp.193-206
    • /
    • 2017
  • In this paper, we propose a rate control method based on the $R-{\lambda}$ model that supports a parallel encoding structure in GOP levels or IDR period levels for 4K UHD input video in real-time. For this, a slice-level bit allocation method is proposed for parallel encoding instead of sequential encoding. When a rate control algorithm is applied in the GOP level or IDR period level parallelism, the information of how many bits are consumed cannot be shared among the frames belonging to a same frame level except the lowest frame level of the hierarchical B structure. Therefore, it is impossible to manage the bit budget with the existing bit allocation method. In order to solve this problem, we improve the bit allocation procedure of the conventional ones that allocate target bits sequentially according to the encoding order. That is, the proposed bit allocation strategy is to assign the target bits in GOPs first, then to distribute the assigned target bits from the lowest depth level to the highest depth level of the HEVC hierarchical B structure within each GOP. In addition, we proposed a processing method that is used to improve subjective image qualities by allocating the bits according to the coding complexities of the frames. Experimental results show that the proposed bit allocation method works well for frame-level parallel HEVC software encoders and it is confirmed that the performance of our rate controller can be improved with a more elaborate bit allocation strategy by using the preprocessing results.