• Title/Summary/Keyword: Korean image

Search Result 29,556, Processing Time 0.07 seconds

Relationship Between Vascularity and Other Remodeling Parameters in Asthmatic Airway (기관지천식환자에서 기도내 혈관분포정도(vascularity) 및 다른 기도 재구성 소견과의 연관성)

  • Kim, Seung Joon;Lee, Sook Young;Kim, Myoung Sook;Lo, Dae Keun;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyoung;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.191-198
    • /
    • 2003
  • Background : The pathological features in asthmatic airway remodeling are diverse. The aim of this study was to examine the degree of airway vascularity in relation to the other remodeling parameters in asthmatics. Methods : Bronchial biopsies were done in 34 asthmatic patients, and 6 control subjects. The basement membrane thickness and the subepithelial thickness were measured in the hematoxylin-eosin stained tissue, and the degree of vascularity was measured using type IV collagen immunostaining. Results : 1) Compared to the control subjects, the asthmatics showed a significant increase in the basement membrane thickness ($6.92{\pm}2.01{\mu}m$ vs $9.67{\pm}2.84{\mu}m$, p<0.05) and the subepithelial thickness ($44.49{\pm}31.92{\mu}m$ vs $121.22{\pm}72.79{\mu}m$, p<0.05). 2) Compared to the control subjects, the asthmatics showed a significant increase in the vascular area per unit submucosal area ($4.51{\pm}2.13%$ vs $10.32{\pm}6.08%$, p<0.05). In addition, the number of vessels per unit submucosal area showed an increased tendency without statistical significance. 3) In the asthmatics, the number of vessels and the vascular area per unit submucosal area showed no correlation with the basement membrane thickness, the subepithelial thickness, the severity, the forced expiratory volume in 1 second($FEV_1$), and the methacholine provocative concentration 20($PC_{20}$). Conclusion : This study showed that vascularity was an important parameter in asthmatic airway remodeling but it was not related to the other remodeling parameters such as the basement membrane thickness and the subepithelial thickness. Each of these asthmatic remodeling parameters may have a different clinical significance. Therefore, further studies will be needed.

Integrated Study on the Factors Influencing Sustainable Innovation Cluster of Pangyo Techno Valley (판교테크노벨리의 지속가능한 혁신 클러스터 영향요인에 관한 통합연구)

  • Park, Jeong Sun;Park, Sang Hyeok;Hong, Sung Sin
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.1
    • /
    • pp.71-94
    • /
    • 2020
  • Korea's innovation cluster policy has been implemented since 2005 with the goal of balanced regional development. The purpose of this study is to investigate the factors affecting the sustainability of innovative cluster tenants by using Pangyo Techno Valley as an example. Pangyo Techno Valley was established under the leadership of the local government (Gyeonggi-do) rather than the central government and it is called "Silicon Valley of Korea" and "Asia Silicon Valley" and is becoming more representative. The growing number of companies in Pangyo Techno Valley decreased in 2017 compared to 2016. This is because Pangyo Techno Valley's business ecosystem will change from 2019. In this paper, quantitative and qualitative studies were conducted to investigate the influencing factors. Quantitative research was conducted based on the survey and qualitative research was applied through interviews. The quantitative research examined the factors affecting the sustainability of Pangyo Techno Valley, and the qualitative research examined the specific reasons and additional factors for the quantitative research results. The quantitative results showed that factors affecting sustainability in terms of changes in corporate internal conditions, human and physical infrastructure, cooperation and synergy, and occupancy patterns. The specific reason for the impact appeared in the qualitative research process. The support category of local governments did not show any significant factors in quantitative research. In addition, qualitative research suggested 'Good image of Pangyo Techno Valley' as the category that has the greatest impact on sustainability. It is shown that companies are passive and expect the role of local governments in activating cooperation network in Pangyo Techno Valley. In this paper, based on the results of the study, Pangyo Techno Valley is presented with a realistic plan based on real estate issues and an ideal plan with a long-term perspective.

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator (선형가속기 방사선 중심점의 크기 측정 방법 개발과 Clinac 21EX 선형가속기의 방사선 중심점 크기 분석)

  • Jeon, Ho-Sang;Nam, Ji-Ho;Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Ki, Yong-Kan;Kim, Dong-Hyun
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of the method was verified. The developed program was used to measure sizes of the radiation isocenters for a Clinac 21EX (Varian, USA) using data of quality assurance (QA) performed from June 2008 to December 2010. To calculated the size of radiation isocenter, positions of two points on each central ray of the star-shot image were found and the equation of the central ray was determined using the positions of two points. Using the equations of central rays the radius of the minimum circle intersecting all the central rays, which is one half of the size of radiation isocenter, was calculated. The program measured x-intercepts and y-intercepts of the central rays within errors of 0.084 mm and sizes of radiation isocenters within 0.053 mm. All the errors were less than the spatial resolution of star-shot images 0.085 mm. The radiation isocenter sizes of Clinac 21EX were $0.33{\pm}0.27mm$, $0.71{\pm}0.36mm$, $0.50{\pm}0.16mm$ for collimator, gantry and couch respectively. During the measurement period all the measured sizes were less than 2.0 mm and within tolerance. The developed program could calculate the size of radiation isocenters and it would be helpful to routine QA.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Diffusion-Weighted MR Imaging of the Brain Tumors: The Clinical Usefulness (두개강내 종양의 확산강조자기공명영상: 임상적 유용성)

  • 이영철;서정진;정광우;강형근;김윤현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • Purpose: To evaluate the clinical usefulness of diffusion weighted MR imaging(DWI) in the differential diagnosis of brain tumors. Materials and methods: DWI and conventional MR images of nineteen patients with brain tumors(10 metastatic tumors, 4 high grade gliomas, 4 low grade astrocytomas, one oligodendroglioma)were obtained on 1.5T unit. DWI was obtained using single shot spin echo planar imaging with b-value near 1000. We analyzed the signal intensities of lesions including solid portion, necrotic or cystic portion and peritumoral edema of brain tumors (classified five grades comparison with the signal intensities of brain parenchyma and CSF)and calculate the SIR(signal intensity ratio)of lesions to the contralateral normal brain parenchyma. We analyzed statistically the signal intensities and SIR of tumors using independence T test. Results: In solid portions of tumors, all the metastatic tumors and high grade gliomas showed high signal intensities, but low grade astrocytomas and oligodendroglioma showed iso or slight high signal intensities to the normal brain parenchyma. The SIR of solid portion has positive correlation with malignant pot ential(metastatic tumors 1.52, high grade gliomas 1.38, low grade astrocytomas 1.16, oligodendroglioma 1.31)(p < 0.05). In peritumoral edema where seen in 14 tumors, seven of 10 metastatic tumors and two of 4 high grade gliomas showed iso signal intensities, whereas edemas in other 5 brain tumors showed hyperintense to the normal brain parenchyma. The SIRs of peritumoral edemas in metastatic tumors (1.14) was lower than high grade gliomas(1.31),but statistically insignificant. The SIR of cystic or necrotic portion of brain tumors was 0.63. In non enhancing solid portions, three of six cases showed hyperintense to the adjacent peritumoral edema. Conclusion: On DWI, the signal intensities of solid portion has positive correlation with malignant potential, and perilesional edema of brain tumors appear various signal intensities owing to "T2 shine through effect" and the extensiveness of vasogenic edema. Another merit using DWI on the evaluation of brain tumors is to improved better delineation of tumor margins from the adjacent edemas, especially at the non enhancing solid portion of the tumors.

  • PDF

A Research on Perception of Leadership Affects Long-term Working Intention in the Beauty Service Employees (미용서비스종사자의 리더십 지각이 장기근속의도에 미치는 영향에 관한 연구)

  • Oh, Jin Sook;Youn, Chun Sung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.4
    • /
    • pp.21-32
    • /
    • 2012
  • The current beauty service of Korea is upgrading its outside appearance from traditional small-shop image and its speed of change and competition are more severe than ever before. The top priority trait of beauty management is based on man-power resource, and personnel-management is the most important thing that more than anything else. Compared with other arenas of business, personnel management plays a key role in beauty industry. As a result, this research begins with the issue of personnel management. In addition, I will show that the management leadership of beauty service affects organization civil actions and changing jobs in the beauty industry employees, and the leadership can lower changing job rate to some extent. The role and duty of business manager is very significant because the dependence of man-power resource is magnificent in beauty service. In spite of rapid changing of economic surroundings, the management of beauty service is still working without any detail plans. It is no exaggeration to say that the most of beauty service managers are lack of leadership conception. Although the demands of customers are changing everyday, the frequent changing of jobs among talented employees drops customers credibility and high-quality service. From a management viewpoint, re-training cost of employees leads to economic loss and the company suffers from financial problems. As a result, it creates vicious circle in the beauty industry. Today, the management atmosphere in the beauty service is hard to get its right track because of the cutthroat competitions of beauty industry and difficulties of hiring promising employees. It has been said that "Nothing ventured, Nothing gained" Above all, the beauty service requires job speciality and it produces economic profits. Therefore, the managers desperately need to change the way they regard those with job changers. In this research shows the principal index of the leadership type of beauty business managers how much affects its employees' long-term working condition. The new concept of leadership, such as alternative suggestions, setting goals, and organization civil action will reorganize the stereo-type frame. I will also investigate the factors of job changing and intention of the beauty service employees for the development option of the beauty industry.

  • PDF

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

Anisotropy Measurement and Fiber Tracking of the White Matter by Using Diffusion Tensor MR Imaging: Influence of the Number of Diffusion-Sensitizing Gradient Direction (확산텐서 MR 영상을 이용한 백질의 비등방성 측정 및 백질섬유 트래킹: 확산경사자장의 방향수가 미치는 영향)

  • Jun, Woo-Sun;Hong, Sung-Woo;Lee, Jong-Sea;Kim, Sung-Hyun;Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Purpose : Recent development of diffusion tensor imaging enables the evaluation of the microstructural characteristics of the brain white matter. However, optimal imaging parameters for diffusion tensor imaging, particularly concerning the number of diffusion gradient direction, have not been studied thoroughly yet. The purpose of this study was to evaluate the influence of the number of diffusion gradient direction on the fiber tracking of the white matter. Materials and methods : 13 healthy volunteers (ten men and three women, mean age 30 years, age range 23-37 years) were included in this study. Diffusion tensor imaging was performed with different numbers of diffusion gradient direction as 6, 15, and 32, keeping the other imaging parameters constant. The imaging field ranged from 1 cm below the pons to 2-3 cm above the lateral ventricle, parallel to the anterior commissure-posterior commissure line. FA (fractional anisotropy) maps were created via image postprocessing, and then FA and its standard deviation were calculated in the genu and the splenium of the corpus callosum on each of FA maps. Fiber tracking of the corticospinal tract in the brain was performed and the number of the reconstructed fibers of the tract was measured. FA, standard deviation of FA and the number of the reconstructed fibers were compared statistically between the different diffusion gradient directions. Results : FA is not statistically significantly different between the different diffusion gradient directions. By increasing the number of diffusion gradient direction, standard deviation of FA decreased significantly, and the number of the reconstructed fibers increased significantly. Conclusion : The higher number of diffusion gradient direction provided better quality of fiber tracking.

  • PDF

MR Findings of Hypoxic Brain Damage: Relation to Time Elapse and Prognosis of Patients (저산소성 뇌손상의 자기공명영상 소견: 유병기간 및 예후와의 연관성)

  • Suh, Kyung-Jin;Kang, Chae-Hoon;Yoo, Dong-Soo;Kim, Sang-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.8-15
    • /
    • 2006
  • Purpose : To describe MR imaging features of hypoxic brain damage in relation to time elapse and prognosis of patients. Materials and methods : We reviewed 19 MR studies of 18 patients with hypoxic brain damage. MR imaging studies were performed between 1 to 20 days after the hypoxic insults (mean 8.6 days). MR images were analyzed with regard to the locations of abnormal signal intensities, the presence of brain edema. And imaging findings were correlated with the time elapse after the insults and the prognosis of patients. Results : On 19 cases of MR studies, abnormal high intensities on T2-weighted images were found in the basal ganglia (15, 78.9%), cerebral cortex (13, 68.4%), white matter (9, 47.4%), thalamus (6, 31.6%), cerebellum (4, 21.1%) and brainstem (1, 5.3%), respectively. Cerebral cortical involvement was typically bilateral and diffuse, but sometimes limited to the parieto-occipital area. The brainstem and cerebellar involvement was rare and in all cases, cerebral cortical lesions accompanied. Most of the white matter lesions were accompanied with cortical and deep gray matter lesions and found in subacute period(>6 days). The cortical high signal intensity lesions on T1-weighted image were found mostly in subacute stage, but in some cases involvement was also found in acute stage ($\leq$ 6 days). The cortical edema is found on 11 cases in acute and subacute stages. In cases of recovered consciousness, cortical involvement and edema on MR were rare. Conclusion : MR findings of hypoxic brain damage were various, but diffuse bilateral involvement of cortex and/or deep gray matter was found in most of the cases. White matter involvement was rarely found in acute stage and usually found in subacute stage. In cases of good pronosis, cortical involvement and edema were rare.

  • PDF