• Title/Summary/Keyword: Korean dual system

Search Result 1,904, Processing Time 0.031 seconds

Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant (정수처리장 사여과지의 이단이중여과재 시스템으로의 개량)

  • Woo, Dal-Sik;Kim, Jooneon;Hwang, Byung-Gi;Chae, Su-Kweon;Jo, Kwanhyung
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.737-742
    • /
    • 2014
  • This study aimed for evaluating the applicability of the two stage dual media filtration system in field water treatment plant. The field plant of two stage and dual media filtration system was operated for 2 months. Average iron concentrations of the settled water, existing filtered water and second stage filtered water was 0.041 mg/L, 0.007 mg/L and 0.005 mg/L, respectively. Removal efficiency of iron concentration in the second stage is appropriately 35% more than in existing filtered water. Also removal efficiency of residual chlorine in the dual media filtration system is relatively 42.3% more than in existing filtered water due to adsorption of activated carbon, but the removal of ammonia nitrogen by adsorption is insufficient. Average concentrations of THM and chloroform in the settled water are 0.033 mg/L, 0.026 mg/L, respectively and in existing filtered water are 0.023 mg/L and 0.023 mg/L. Average concentrations of THM and chloroform in the dual media filtration system are 0.008 mg/L and 0.013 mg/L. Therefore removal efficiency of THM concentration in second stage is more than 66.4% in existing filtrated water. Also removal efficiency of chloroform in the dual media filtration system is more than 50.0% in existing filtered water because of the adsorption of activated carbon. In this case backwashing period in dual stage system is 4~5 days, but in existing filtration system is 1~2 days.

Design of an Active Adaptive Dual Controller for Non-Minimum Phase Systems (비최소 위상시스템에 대한 능동적응 이중 제어기의 설계)

  • 김도성;안태천;이명호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.9
    • /
    • pp.380-387
    • /
    • 1986
  • We have developed a dual control algorithm by means of innovations approach and established the stability of dual by introducing the pole-placement method suggested by Berger on the non-dual control. The dual controller realizing this algorithm decreases control loss sharply when compared with that of a non-dual controller, and shows the characteristics of suppressing the output deviation in transient state effectively. The total control energy and the accumulated square misdistance of this dual controller are shown to be 1-10% and 0.1-10% of those of CE control, respectively. Consequently this controller solves the non-minimum phase problem encountered when discretizing the system equation, and can be used to overcome the uncertainty of system effectively by adjusting the learning rate of the controller.

  • PDF

Improvement of Sense Mode Bandwidth of Vibratory Silicon-On-Glass Gyroscope Using Dual-Mass System (이중 질량체를 사용한 진동형 자이로스코프의 검출부 대역폭 개선)

  • Hwang, Yong-Suk;Kim, Yong-Kweon;Ji, Chang-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1733-1740
    • /
    • 2011
  • In this research, a MEMS vibratory gyroscope with dual-mass system in the sensing mode has been proposed to increase the stability of the device using wide bandwidth. A wide flat region between the two resonance peaks of the dual-mass system removes the need for a frequency matching typically required for single mass vibratory gyroscopes. Bandwidth, mass ratio, spring constant, and frequency response of the dual-mass system have been analyzed with MATLAB and ANSYS simulation. Designed first and second peaks of sensing mode are 5,917 and 8,210Hz, respectively. Driving mode resonance frequency of 7,180Hz was located in the flat region between the two resonance peaks of the sensing mode. The device is fabricated with anodically bonded silicon-on-glass substrate. The chip size is 6mm x 6mm and the thickness of the silicon device layer is $50{\mu}m$. Despite the driving mode resonance frequency decrease of 2.8kHz and frequency shift of 176Hz from the sensing mode due to fabrication imperfections, measured driving frequency was located within the bandwidth of sensing part, which validates the utilized dual-mass concept. Measured bandwidth was 768Hz. Sensitivity calculated with measured displacement of driving and sensing parts was 22.4aF/deg/sec. Measured slope of the sensing point was 0.008dB/Hz.

Optical Disk Drive Servo System using Modified Disturbance Observer (수정된 외란관측기를 이용한 광디스크 드라이브 서보 시스템)

  • Jeong, Jong-Il;Chung, Chung-Choo;Pyo, Hyeon-Bong;Park, Yong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.372-375
    • /
    • 2003
  • Using disturbance observer is effective to enhance tracking performance of system in the presence of disturbances. Various types of disturbance observers have been proposed to improve sensitivity of systems, but they tend to bring poor transient response due to cross coupling of inter-loops. In this paper, we propose dual disturbance observer(Dual DOB) which is designed to reduce the cross coupling. Dual DOB is consist of an internal DOB and an external DOB, that are designed for different object. The Dual DOB is applied to Optical Disk Drive tracking system. It is shown that the Dual DOB has improved performance over conventional DOB via experimental result. There is good agreement between simulation and experimental results.

  • PDF

MSE of Dual-k Convolutional Codes for an AWGN Channel with Rayleigh Fading (Rayleigh Fading AWGN채널에 대한 Dual-K길쌈부호의 평균자승오차)

  • 문상재
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.04a
    • /
    • pp.1-3
    • /
    • 1986
  • We are concerned with transmitting numerical source data of {0, 1, 2, ..., 2k-1} through a channel coding system. The rate 1/v dual-k convolutional code with the orthogonal MFSK modulation and the Viterbl decoding is employed for the implementation of the channel coding system. The mean square error of the dual-k convolutional code is evaluated for the numerical source transmitted over an additive white Gaussian noise channel with Rayleigh fading.

  • PDF

Predictive Current Control of 12-Pulse Parallel Connected Dual Converter System (12펄스 병렬 연결 듀얼 컨버터 시스템의 예측전류제어)

  • 이창원;송인호;최창호
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.405-408
    • /
    • 1998
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system with interphase transfromer(IPT) is presented. Firstly, 12-pulse parallel connected dual converter system and the predictive current control of this system is discussed. And the validity of the presented system and the excellence of the predictive current control response is proved through the simyulation and experiment result.

  • PDF

Dual-Contact Tooling System for 5-Head Router Machine (5-Head Router Machine 의 이면 구속 공구 시스템)

  • 성승학;이득우;이채문;백효정;옥주선;최운집
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.788-791
    • /
    • 2004
  • This paper presents a general description of single and dual contact tooling systems, finite element analysis, and discussions on the application of the system to the 5-head router machine which is in particular for aerospace components. This study has been performed as part of the development of the new generation 5-head router machine which is designed for high productivity. Such high productivity in essence requires high speed rotation and multiple spindles in one machine. The high speed rotation may exceed a range in a conventional single contact tooling system. The conventional tooling system is reevaluated in comparison with the dual-contact system. Finite element analysis using simplified spindle models compares major differences in the two systems. Some problems in the application to the 5-head router machine are discussed.

  • PDF

Design of Intelligent Digital Controller with Dual-Rate Sampling (듀얼 레이트를 갖는 지능형 디지털 제어기 설계)

  • Kim, Do-Wan;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.04a
    • /
    • pp.559-562
    • /
    • 2004
  • In this paper, a new dual-rate digital control technique for the Takagi-Sugeno (T-S) fuzzy system is suggested. The proposed method takes account of the stabilizablity of the discrete-time T-S fuzzy system at the fast-rate sampling points. Our main idea is to utilize the lifted control input. The proposed approach is to obtain the dual-rate discrete-time T-S fuzzy system by discretizing the overall dynamics of the T-S fuzzy system with the lifted control, and then to derive the sufficient conditions for the stabilization in the sense of the Lyapunov asymptotic stability for this system.

  • PDF

A POLAR REPRESENTATION OF A REGULARITY OF A DUAL QUATERNIONIC FUNCTION IN CLIFFORD ANALYSIS

  • Kim, Ji Eun;Shon, Kwang Ho
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.2
    • /
    • pp.583-592
    • /
    • 2017
  • The paper gives the regularity of dual quaternionic functions and the dual Cauchy-Riemann system in dual quaternions. Also, the paper researches the polar representation and properties of a dual quaternionic function and their regular quaternionic functions.

The Dual Design of Fuel Cell Hybrid Power System using Dual Converter PCS (1.5kW 연료전지 복합발전 시스템의 듀얼 컨버터 설계)

  • Shin, Soo-Cheol;Lee, Hee-Jun;Hong, Suk-Jin;Kim, Hak-Sung;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.67-75
    • /
    • 2013
  • In this paper, parallel input/serial output dual converter is designed appropriately for fuel cell hybrid power system. In case of proposed converter, zero voltage switching condition is designed without additional resonance device using leakage inductance of transformer and output capacitance of switch, and zero voltage switching method is used. Also, the system method is for increasing power by connecting half-bridge in parallel and increasing output voltage by connecting secondary output of transformer in serial. Through this method we can increase power and decrease volume of system. So in this paper, dual converter is designed. 1.5kW fuel cell hybrid power system was implemented, and system operation and stability was verified through experiment.