Experimental Study on Compact type CO2 Gas Cooler(1) - Heat Flowrate and Pressure Drop in a Multi-Tube-In-Tube Helical Coil Type Gas Cooler - (CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(1) -다중관식 헬리컬 코일형 가스냉각기내 CO2의 열유량과 압력강하-)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.30-36
    • /
    • 2010
  • The heat flowrate and pressure drop of $CO_2$ in a multi-tube-in-tube helical coil type gas cooler were investigated experimentally. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat flowrate of $CO_2$ in the test section is increased with the increase in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat flowrate of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly higher than that of $CO_2$ in the double pipe type gas cooler, while the pressure drop of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly lower than that of $CO_2$ in the double pipe type gas cooler. Therefore, in case of the application of $CO_2$ at the multi-tube-in-tube helical coil type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

Pressure drop and heat transfer characteristics of a flat-plate solar collector with heat transfer enhancement device (열전달 향상 장치에 따른 평판형 태양열 집열기의 압력강하 및 열전달 특성)

  • Ahn, Sung-Hoo;Shin, Jee-Young;Son, Young-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.453-460
    • /
    • 2013
  • The surface roughness and heat transfer enhancement devices are known to increase the performance of a flat plate soar collector. This study includes the experiments on the effect of the several heat transfer enhancement devices inserted in duct to simulate the flat-plate solar collector. Experiment was basically at a constant heat flux on the upper duct wall. Inserted heat transfer enhancement devices are Chamfered rib $10^{\circ}$, Chamfered rib $20^{\circ}$, Rib & Groove and Rib & Dimple. Reynolds number is in the range of 2,300 to 22,000 which corresponds to turbulent regime. With the heat transfer enhancement devices, heat transfer would increase by the secondary flow and the increase of the heat transfer area. Pressure drop also increases with the insertion of the enhancement devices. Rib & Dimple model is the best in heat transfer enhancement, however, Chamfered rib $10^{\circ}$ model is the lowest in the pressure drop. Considering the heat transfer enhancement simultaneously with low pressure drop increase, performance factor was the best for the Chamfered rib $10^{\circ}$.

Two Cases of Radial Nerve Palsy with Chuna Treatment on Cervical Vertebrae (경추 추나치료를 적용한 압박성 요골신경마비 환자 치험 2례)

  • Heo, Su-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.89-96
    • /
    • 2011
  • Objective : The purpose of this study is to evaluate the korean medical treatment for compressive neuropathy of radial nerve, especially chuna treatment of cervical vertebrae. Methods : Two patients were treated with acupuncture and moxibustion, herbal medication, chuna treatment on cervical vertebrae. To evaluate the wrist drop and numbness of hand, Coding Result of arbitrary values and manual muscle test(MMT), visual analogue scale(VAS) were used. Results : After 2 weeks-treatment(in case 1) & 5 weeks-treatment(in case 2), the movement and power of wrist were restored to nearly normal range, also the numbness of hands was removed. All cases show the improvement in the movement of wrist and the numbness of hands. Conclusions : Korean medical treatment including cervical manual therapy as chuna treatment is remarkably effective for radial nerve palsy. But further studies are required to concretely prove the effectiveness of chuna treatment on central vertebrae for peripheral neuropathy.

  • PDF

Effects of an Anti-wind Net on Wind Velocity Reduction by a Wind Tunnel Test and CFD (풍동시험과 CFD를 통한 방풍망의 풍속저감 효과)

  • Yum, Sung-Hyun;Kang, Seung-Hee;Kim, Seoung-Hee;Lee, Sang-Bong;Kim, Min-Young
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.355-360
    • /
    • 2011
  • This study was carried out to analyze the installation effect of an anti-wind net on reducing wind velocity which was used to protect orchards as well as single-span plastichouses. The pressure drop through three types of anti-wind net was measured in a subsonic wind tunnel. The wind reduction through the anti-wind facility for several sets in respect to three types of the net and heights of the facility ranging from 3 to 11 m was analyzed by using computational fluid dynamics (CFD). The measured data showed that the pressure drop increased as an equation of the second degree of the inlet wind velocity. Numerical computations exhibited that the effect of wind reduction definitely augmented as the net size became smaller and increased with the height of the facility being heightened to some extent. For the typical and widely used anti-wind facility with a height of 5 m and a net size of 4mm, the amount of wind reduction came up to 5.1 m/s for the inlet wind velocity of 20 m/s, and also 7.6 and 10.1 m/s for the inlet wind velocities of 30 and 40 m/s, respectively. In case for the orchard's longitudinal length to be within about 200 m, the appropriately effective height of the facility was predicted to be 5 m. Finally, the negative total pressure on the top face of the single-span plastichouse certainly reduced for all the cases with the anti-wind facility being installed. In particular, the reduction of the negative total pressure was more considerable as the inlet wind velocity increased.

An Experimental Study on the Toluene Control Characteristics of Biofilter Packed with Compost, Peatmoss and GAC (Compost, Peatmoss, GAC의 복합 메디아로 충전된 Biofilter의 Toluene 제어특성에 관한 실험적 연구)

  • Eom, Yun-Sung;Han, Se-Hyun;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.265-276
    • /
    • 2007
  • The primary objective of this study is to investigate the effect of media on the performance of biofilters. Two types of experiments were carried out in this study. The first type of experiment used a biofilter with the media composed of three different packing materials of compost, peatmoss and GAC(granular activated carbon), whereas the second type used a biofilter with the media composed of compost only. It was found from the two experiments that the biofilter composed of compost, peatmoss and GAC showed better performance than the one composed of compost only with the higher toluene removal efficiency, lower pressure drop, and more uniform media moisture content. In particular, no appreciable media compression occurred for the biofilter composed of compost, peatmoss and GAC, whereas significant media compression took place in the biofilter composed of compost only. As suggested by the other researchers, it is likely that GAC may be responsible for the higher toluene removal efficiency in the case of the biofilter composed of mixed media especially for the early stage of biofiltration due to its adsorption capability of toluene of such high concentration as 300 ppm. It was also regarded that GAC may playa major role in maintaining lower media pressure drop in the case of the mixed media than the media with compost only because of its mechanical strength resisting to the compression. Nonetheless, further refined experiments may need to draw more accurate conclusion. The results of the additional test run using the same mixed media showed that the biofilter system using the mixed media can be consistently operated for more than 100 days very stably despite sudden change in operating conditions of temperature and flow rate.

The Holding Power of the Oil Boom Anchor (오일 펜스 Anchor의 파주력)

  • CHANG Duk Jong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.743-748
    • /
    • 2003
  • An oil boom was set up in order to contain diffused oil from spills and for the retrenchment of damage caused by oil Pollution. Therefore, the oil boom anchor needed proper holding power to endure high resistance from flowing streams and to secure the oil boom around the spill, and must dredge directly into the seabed when it is dropped and block oil outflow immediately. This study investigated the holding power of the danforth anchor and the coastal fishing vessel anchor used for oil booms in the KMPRC (Korea Marine Pollution Response Corporation). For each type, a 30 kg and 20 kg anchor were used. The holding power of the danforth anchors were measured by dropping both weights 10 times. However the coastal fishing vessel anchors were dropped only 5 times each, because no substantial differences were found between drops. In the results of the danforth anchors, an anchor awoke occurred in 2 drops of the 30 kg anchor and in 4 drops of the 20 kg anchor, wherein there was no holding power to be measured. With exception to the anchor awoke cases, the maximum holding power of the danforth 30 kg and 20 kg anchors was 250-520 kg and 123-233 kg, respectively. In the case of the coastal fishing vessel anchors of 30 kg and 20 kg, throughout the experiment, there was no occurrence of an anchor awoke. For the 30 kg and 20 kg anchors, the maximum holding power was measured to be 209-230 kg and 155-170 kg, respectively. Therefore, the holding power of the coastal fishing vessel anchor was shown to be much poorer than that of the danforth anchor. However, the holding power of the danforth anchor was very unstable. Due to the occurrences of anchor awoke, there was no holding power and the measurement value of maximum holding power showed too much variation among the drop tests. Also, after the maximum holding power was achieved, anchor awoke occurred easily. In the case of the coastal fishing vessel anchor was much more stabile, because there was no anchor awoke and no instance where holding power failed. Also the maximum holding power was reached quickly and almost no variation occurred among the drop tests.

An Estimation of Buckling-Strength of Braced Rectangular Latticed Domes (브레이스로 보강된 사각형 래티스돔의 좌굴내력 평가)

  • Hwang, Young-Min;Suk, Chang-Mok;Park, Sang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.4 s.10
    • /
    • pp.69-76
    • /
    • 2003
  • In case of rectangular latticed pattern which shearing rigidity is very small, it has a concern to drop Buckling-strength considerably by external force. So, by means of system to increase buckling-strength, there is a method of construction that lattice of dome is reinforced by braced member. In a case like this, shearing rigidity of braced member increase buckling-strength of the whole of structure and can be designed economically from the viewpoint of practice. Therefore, this paper is aimed at investigating how much does rigidity of braced member united with latticed member bearing principal stress of dome increase buckling-strength of the whole of structure. the subject of study is rectangular latticed domes that are a set of 2-way lattice dome which grid is simple and number of member gathering at junction is small. Analysis method is based on FEM dealing with the geometrically nonlinear deflection problems.

  • PDF

The Variation of Cooling Charateristics Due to the Weber Number of Droplet (액적의 Weber 수에 따른 냉각특성의 변화)

  • 방창훈;양창호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 2003
  • The objective of the present work is to examine the variation of cooling characteristics due to the Weber number of droplet on a heated surface. The surface temperatures varied from 72.5 - $106.1^{\circ}C$ on steel and Teflon, when Weber number was 60, 180, 300. The results are as follows; In the case of the same droplet size, the initial temperature of solid increases the indepth temperature of solid more drop. In the case of the same surface temperature, Weber number increases with increasing the cooling effect of droplet. The time-average heat flux increases with increasing the initial temperature of solid and Weber number. The evaporation time decreases with increasing the initial temperature of solid and Weber number.

Influence of Fiber Strength and Stacking Sequences on Impact Damages of CFRP Composites (섬유강도와 적층구성이 CFRP적층판의 충격손상에 미치는 영향)

  • 임광희;박노식;양인영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.210-220
    • /
    • 2001
  • This paper aims at the evaluation on the characterization of CFRP laminate plates using falling weight impact tester. The experimentation was conducted on several laminates of different fiber and ply orientation. A system was built for the impact strength of CFRP laminates in consideration of stress wave propagation with using drop-weight impact tester as one of impact test. Absorbed energy of orthotropic composites with using T300 fiber, which are composed of the same fiber and stacking number is higher than that or quasi-isotropic specimen over impact energy 7J, but in case or using T700 fiber, much difference does not show. Also, absorbed energy of orthotropic composites with using T300 fiber, which are composed or stacking number and orientation became more than that of T700 fiber specimen; however great change doesn't show in case of quasi-isotropic specimens. It is found that influence was confirmed between impact energy and absorbed energy as the impact energy is increased with adding the falling weight.

  • PDF

Loop Current Calculation based on Voltage Angle Difference at Tie Switch for Switching Plan Validation in Distribution System Operation (상시개방점 양단전압 측정값을 이용한 배전선로 루프운전 가능 여부 판단 방법)

  • Son, Juhwan;Lim, Seongil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.14-21
    • /
    • 2015
  • Distribution systems are operated in radial structure, but temporal loop structure could be founded the live load transfer. Main purposes of reconfiguration of distribution network are load balancing, loss minimization and voltage drop maintaining. In the loop structure, huge loop current can be flowed between two substations in case of large voltage angle difference. Protection devices of distribution line can be triped by this huge loop current. So, precise calculation of loop current is very important for secure switching. This paper proposes a novel calculation method of loop current using the voltage angle differences measured at the tie switches. Feasibility of the propose method has been verified by various case studies based on Matlab simulation.