• Title/Summary/Keyword: Korean architectural properties

Search Result 674, Processing Time 0.024 seconds

Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption (창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석)

  • Kwak, Hee-Jeong;Jang, Hyang-In;Lee, Hyun-Soo;Eom, Jae-Yong;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.

Influence of Foaming Agents on the Properties of Foamed Concretes Having Various Densities

  • Kim, Jin-Man;Jeong, Ji-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.1
    • /
    • pp.22-30
    • /
    • 2012
  • Four types of foaming agents, including Alcohol Ethoxy Sulfate (AES), Alpha Olefin Sulfonate (AOS), Vegetable Soap (VS), and Fe-Protein (FP), are widely used in the construction field. These have different surface tensions and viscosities in water of the same concentration, affecting the flow speed of liquid, size and distribution of foam, and foam stability. However, there is a lack of data regarding the properties of foam concrete using various foam agents. The purpose of this study is to investigate influence of foaming agents on the properties of foamed concretes with various densities. We find that the foaming agent type has little effect on the density, compressive strength, and thermal conductivity of foam concrete, but considerably affects the unit weight of foam, flow and flexural strength of foamed concrete. While almost all properties of foam concrete are affected by density in fresh or hardened state, the potential energy changed by slurry density and the viscosity of foam are dominant factors in the flowability of foam slurry.

The Study of Costume Exhibition in Architectural Structures Heritage - Focused on Seoul, Incheon, Gyonggi-do - (유적건조물 문화재 내의 복식 전시물에 대한 연구 - 서울, 인천, 경기도를 중심으로 -)

  • Kwon, Soo-Hyun;Kang, Soon-Che
    • Journal of the Korean Society of Costume
    • /
    • v.62 no.6
    • /
    • pp.182-199
    • /
    • 2012
  • The purpose of this study is to analyze the actual status of costume exhibitions displayed in architectural structures heritage today to examine if they play proper roles as visual materials and suggest the necessity of post-management for comfortable viewing. This is significant in that it makes costume exhibitions function as educational culture contents to let Korean and also foreign viewers know of our costume culture properly. As a research method, the database of the Office of Cultural Properties homepage was used to extract anything related to the lives of figures during the Chosun Dynasty among the architectural structures heritages in Seoul, Incheon, and Gyeonggido. By doing so, the costume exhibitions were able to be examined among them. With field investigation and interviews of related institutions, this study examined the current status of costume exhibitions, planning of exhibitions, and post-management. Also, they found costume exhibitions that were not right for the era, and suggested ways that were more appropriate for them. The results of this study were as follows : First, according to the third selection results, there were only six among 71 places where three districts of the architectural structures heritage were present. This is a very small quantity of places when compared with the total number of architectural structures heritage. Second, as a result of the current condition investigation, the costume exhibition in the Architectural Structures Heritage is not nearly enough for a historical investigation, and almost all polluted costumes were not displayed in suitable environments for an exhibition. Therefore, qualified managers who have expertise in exhibition planning were needed to be trained to do a post-management follow up. Furthermore, it is important to systematically reorganize post-management methods. Third, the two selected places(Haepung-buwongun-yuntaegyeong-jaesi and Sunaedong-gaok) were thought not to be right for the era among the six places with costume exhibitions, and suggestions such as flat-drawing and illustration were made.

Evaluation of Mechanical Properties and Alkali-Silica Reaction of High Strength Mortar Using Waste Glass Sand (폐유리 잔골재를 치환한 고강도 모르타르의 역학적 특성 및 알칼리-실리카 반응 평가)

  • Eu, Ha-Min;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Son, Min-Jae;Nam, Jeong-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.528-536
    • /
    • 2020
  • In this study, high strength mortar and normal strength mortar using waste glass sand were evaluated. The main parameters studied were mechanical properties, alkali-silica reaction(ASR) and residual mechanical properties after ASR. As a result of this experiment, it was found that the increase in strength of the mortar has a limitation in improving the slip of the waste glass sand(GS), and rather, it causes a larger ASR. However, the possibility of improving the slip of GS was confirmed by the temporary increase of initial residal compressive and flexural strength of the mortar containing GS after the ASR. Therefore, to improve the slip of GS, the additional research is required, such as modification of the surface of GS and the incorporation of a binder which can increase the strength and makes matrix compact.

A Study on Compressive Strength of Built-up H Shaped Columns Fabricated with HSA800 High Performance Steels (건축구조용 고성능강(HSA800) 용접 H형단면 기둥의 압축강도에 관한 연구)

  • Kim, Tae Soo;Lee, Myung Jae;Oh, Young Suk;Lee, Kang Min;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.627-636
    • /
    • 2012
  • Recently, high performance(strength) steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using high performance steel, material properties of high performance rolled steel building structures; material properties of HSA800 steel was compared with the requirements of Korean Standards(KS) for HSA800. Welded H-shape stub columns with variables of width-to-thickness ratios are planned in order to investigate the local buckling behaviors and check the current design limit of width-to-thickness ratio and uniaxial compressive tests are carried out. In addition, the buckling behaviors of stub columns obtained finite element analysis were compared with those of test results.

Flow and Engineering Properties of Fiber Reinforced Hwangtoh Mortars

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Hwang, Hye-Zoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.3
    • /
    • pp.332-339
    • /
    • 2012
  • In this study, six mortar mixes were tested in order to examine the significance and limitations of hydrophilic fiber in terms of its capacity to enhance the tensile resistance of Hwangtoh mortar. Lyocell, polyamide and polyvinyl alcohol (PVA) fibers were selected for the main test parameters. The tensile capacity of mortars tested was evaluated based on the splitting tensile strength and the modulus of fracture, while their ductility was examined using the toughness indices specified in ASTM. Test results showed that the addition of lyocell and PVA fibers had little influence on the flow of the Hwangtoh mortars. To enhance the tensile capacity and toughness index of Hwangtoh mortar, it is proposed that fiber spacing above 0.0003 is required, regardless of the type of fiber.

Evaluation of Pumping Characteristics of High Strength Concrete using Continuous Pumping System

  • Kwon, Dae-Hun;Lee, Han-Seung;Jeon, Jun-Young;Jeong, Woong-Taek;Jo, Ho-Kyoo;Kim, Hyung-Rae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.387-395
    • /
    • 2011
  • In the construction of tall-building, concrete pumping influences the success of the project. In order to establish pumping technology for high speed construction of tall building, study for quantitative evaluation of flow characteristics and pumpability should be conducted. So in this study, the characteristics including the inner pipe pressure, rheological properties of concrete and mortar through the continuous pumping test were evaluated. Then we analyzed the relations between rheological properties and pumpability. In the result of test, there are high correlations between the rheological characteristics which represented by yield stress and plastic viscosity and pressure loss with pipe length. Also, we estimated pressure loss according to conditions of concrete mix and pumping through the evaluation of inner pipe friction.

Engineering Properties of Some Sedimentary Rocks from the Gyeongsang Supergroup (경상계(慶尙系) 퇴적암(堆積岩)의 공학적(工學的) 성질(性質)에 관(關)한 연구(硏究))

  • So, Chil-Sup;Choi, Byoung-Ryol
    • Economic and Environmental Geology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 1975
  • The engineering properties of some Gyeongsang sedimentary rocks with respect to the grain size and the orientation of bedding planes were studied. The suitability of the rocks for civil and architectural construction was also investigated. The porosity of the rocks increases in proportion to the grain size. The ratio of the strain due to stress perpendicular to the bedding planes to the strain resulting from stress parallel to the bedding planes increases as the grain size decreases. The study indicates however, that the ratio of Young's modulus due to stress perpendicular to the bedding planes to Young's modulus resulting from stress parallel to the bedding planes increases in proportion to the grain size. The compressive strength of the sandstones studied is much greater than the strength of the conglomerate or shale. Only the coarse grained sandstone can be used for civil and architectural construction, regardless of the orientation of bedding planes. The relationships between compressive strength and density, elasticity and porosity, and compressive strength and mineral content were also studied.

  • PDF

Housing owner's decision making of architectural design process in the rural area of KANG-NEUNG (강릉시 농촌지역 주택건축 설계과정에서의 건축주 의사결정에 관한 연구)

  • Cho, Won-Seok;Kwon, Young-Gyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.1 no.2
    • /
    • pp.29-37
    • /
    • 1999
  • This study was analyzed and researched into each gradual properties of housing owner's decision making, for preservation of traditional scenery and search for the way its succession, on the basis of search of the rural area housing owner and the virtual research data. As a result of this study, public company should care and advertise significance of traditional scenery succession to housing owners and architectural planning offices, because the model what public company has been developed and distributed should not be ignored influence on the process of housing owner's decision making.

  • PDF

Evaluation of Spatial Consolidation Settlement by Probabilistic Method (확률론적 방법을 이용한 공간적 압밀침하량 평가)

  • Kim, Dong-Hee;Choi, Young-Min;Ko, Seong-Kwon;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.475-479
    • /
    • 2010
  • For a rational evaluation of the spatial distribution of consolidation settlement, it is necessary to adopt probabilistic method. In this study, mean and standard deviation of consolidation settlement of whole analysis region are evaluated by using the spatial distribution of consolidation layer which is estimated from kriging and statistics of soil properties. Using these results and probabilistic method, the area need to be raised the ground level for balancing the final design ground level are determined.

  • PDF