• 제목/요약/키워드: Korean Standard Eye Test

검색결과 35건 처리시간 0.028초

Machine Vision Technique for Rapid Measurement of Soybean Seed Vigor

  • Lee, Hoonsoo;Huy, Tran Quoc;Park, Eunsoo;Bae, Hyung-Jin;Baek, Insuck;Kim, Moon S.;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: Morphological properties of soybean roots are important indicators of the vigor of the seed, which determines the survival rate of the seedlings grown. The current vigor test for soybean seeds is manual measurement with the human eye. This study describes an application of a machine vision technique for rapid measurement of soybean seed vigor to replace the time-consuming and labor-intensive conventional method. Methods: A CCD camera was used to obtain color images of seeds during germination. Image processing techniques were used to obtain root segmentation. The various morphological parameters, such as primary root length, total root length, total surface area, average diameter, and branching points of roots were calculated from a root skeleton image using a customized pixel-based image processing algorithm. Results: The measurement accuracy of the machine vision system ranged from 92.6% to 98.8%, with accuracies of 96.2% for primary root length and 96.4% for total root length, compared to manual measurement. The correlation coefficient for each measurement was 0.999 with a standard error of prediction of 1.16 mm for primary root length and 0.97 mm for total root length. Conclusions: The developed machine vision system showed good performance for the morphological measurement of soybean roots. This image analysis algorithm, combined with a simple color camera, can be used as an alternative to the conventional seed vigor test method.

PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링 (Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients)

  • 황수환;윤희남;정다운;서상원;이유진;정도언;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권3호
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성 (Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT)

  • 함준철;강천구;조석원;반영각;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.71-75
    • /
    • 2013
  • 현재 PET/CT 검사에서 저선량 CT를 이용한 감쇠 보정을 사용하고 있다. 하지만 환자 호흡으로 인한 횡격막 부근의 저선량 CT 영상과 Emission 영상의 불일치로 감쇠 보정영상에서 Artifact가 발생하는 경우가 있다. 본 연구는 보정방법 중 CTAC Shift를 이용하여 환자의 호흡에 의한 Artifact의 감소를 연구했다. 2012년 3월부터 9월까지 PET/CT Discovery 600 (GE Healthcare, MI, USA) 장비를 이용하여 호흡에 의한 Artifact가 발생한 환자 30명을 대상으로 했다. Artifact가 발생한 환자는 횡격막 부분을 추가검사하였고, 전신 검사 시 Artifact가 발생한 영상을 CTAC Shift를 이용하여 보정했다. Artifact 발생 영상, 추가 검사영상, CTAC Shift 보정 영상의 육안적 평가는 핵의학 전문의 1명과 5년 이상 근무한 방사선사 4명에 의해 1-5점으로 나누어 평가했다. 또한 각 영상의 표준섭취화 계수를 ANOVA를 이용하여 비교했다. Artifact 발생 영상에 비해 추가 검사 영상과 CTAC Shift 보정 영상은 육안적 평가에서 상대적으로 높은 점수를 받았다. 추가 검사 영상과 CTAC Shift 보정 영상은 표준섭취화 계수의 ANOVA 결과, 높은 상관관계를 갖고 있으며, 유의한 차이를 보이지 않았다. PET/CT 검사 시 환자의 호흡에 의한 Artifact가 발생 할 경우 추가 검사로 인한 검사 시간이 증가하여 환자의 불편 뿐 아니라 피폭도 증가한다. 하지만 추가 검사 없이 CTAC Shift를 이용하여 보정된 영상을 획득한다면 불필요한 피폭 및 추가 검사도 감소하며, 정확한 진단에 도움을 줄 것으로 사료된다.

  • PDF

국도유출부 안전진단을 위한 시선유도시설의 유형별 기능검토 (A Study on Function of the Delineation System by Pattern for Safety Audit on Road Exit Ramp)

  • 금기정;김홍상;민경태;양계승
    • 한국도로학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-11
    • /
    • 2006
  • 현재 국도개량사업으로 국도의 이동성이 향상되었으나 유출부에 설치된 도로안전시설인 시선유도시설은 일관성 없이 설치되거나 미설치된 경우가 많다. 유출부의 시선유도시설은 유출부의 안전성을 높이는 시설임에도 불구하고 각 유출부마다 서로 다른 유형으로 설치되어 그 기능적 검토가 필요할 것으로 판단하였다. 이에 본 연구에서는 현장조사를 통하여 조사된 시설유형별로 설치기준의 적합성을 검토한 후 운전자 인지특성을 고려한 효과적인 시설유형을 제시하고자 하였다. 이를 위하여 3D-시뮬레이션을 개발하여 보다 객관적인 비교실험을 수행하였다. 시설유형 간 비교변수는 운전자 인지특성을 대변할 수 있는 현저성, 시인성으로 선정하여 시설유형에 대한 각각의 특성실험을 수행하였으며 인지 특성변수로 채택된 시인성의 실험에 대한 피 실험자의 측정오차를 줄이기 위하여 초점기록계(Eye Marker Recorder)를 이용하여 실험함으로서 보다 정량적이고, 객관적인 주시빈도를 측정할 수 있었다. 각각의 측정 변수들에 대한 시설유형 간 유의성을 검증하기 위하여 분산 분석으로 검토하였다. 그 결과 현저성은 시설유형 간 유의미한 차이를 나타냈으며, 유출부를 인지하는데 안전표지, 장애물표적표지, 시선유도등, 시선유도봉이 설치된 시설유형이 가장 유리한 것으로 평가되었다. 또한 시인성의 효과척도로 주시빈도를 측정한 결과 시설유형 간 유의미한 차이를 알 수 있었으며, 현저성과 동일한 시설유형이 설치되었을 때 유출부를 인지하는데 유리한 것으로 평가되었으며 전체적인 결과를 종합하여 볼 때 안전표지, 장애물표적표지, 시선유도등, 시선유도봉의 시설이 가장 유리한 것임을 알 수 있었다.

  • PDF

한우 도체형질의 유전능력평가를 위한 통계모형 탐색 (Research of Statistical Model for Genetic Evaluation of Hanwoo Carcass Traits)

  • 구양모;김시동;김정일;송치은;이기환;정용호;이재윤;장현기;박병호;최태정;조광현;이승수;이정규;김효선
    • Journal of Animal Science and Technology
    • /
    • 제53권4호
    • /
    • pp.283-288
    • /
    • 2011
  • 2006년부터 2009년까지 축산물품질평가원에서 등급 판정된 도체성적이 있는 개체와 한국종축개량협회에 등록이 확인된 231,382 두의 자료를 이용하여 각 도체형질의 자료구조 분석 등을 살펴보고, 각 요인별로 도체형질에 어떠한 영향을 주는 지에 대한 환경효과 등을 분석하고, 변수선택법 등을 이용하여 향후 유전능력평가에서 사용 가능한 통계모형 찾아내고자 실시하였다. 한우 암, 수, 거세를 포함한 전체집단에서 출하체중, 도체율, 등 지방두께, 근내지방도에서 정규분포를 보이고 있었고, 다른 형질은 정규분포에 근접함을 확인할 수 있었다. 각 요인에 대한 분산분석에서는 한우 도체형질에 대하여 성별, 출생년도-계절, 도축년도-계절, 출생지역, 도축일령의 모두 고도의 유의성(p<0.01)이 인정되었다. 변수선택법을 이용한 모형적합도 검정에서는 출하체중, 도체중, 도체율, 배최장근단면적은 다섯 가지 환경효과를 선택하는 것이 최적이었고, 등지방두께와 근내지방도는 네 가지 환경효과를 고려하는 것이 최적이었지만, 다형질 분석으로 한 번에 분석을 하기 위해서는 다섯 가지 환경효과를 함께 고려하는 것이 적합하다고 사료된다.

파일드라이버 기계 시공성능 향상을 위한 연직 자동제어기의 개발 (A Development of the Automated Vertical Controllable Device for Improving Construction Performance of Pile Driver)

  • 조창연;이준복;손재호;김한수;조문영
    • 한국건설관리학회논문집
    • /
    • 제7권4호
    • /
    • pp.78-90
    • /
    • 2006
  • 대부분의 건축 토목공사의 기초공사 시 사용하는 기성콘크리트 파일공사의 굴착 및 파일 매입 작업의 경우 국내 시방기준에는 파일을 연직으로 시공해야한다는 것만이 명시되어 있을 뿐, 이에 대한 측정기준 및 시공기준이 제시되어있지 않으며, 대부분의 시공현장에서는 숙련노무자의 경험을 통한 육안측정에 의존하고 있는 실정이다. 본 연구의 목적은 기수행된 PHC 파일 시공성능 향상을 위한 연직 자동제어기 파일롯타입(pilot-type) 연구를 바탕으로 PHC파일 시공 시 균일한 시공품질을 확보하고 작업의 안전성 확보 및 생산성 향상을 위한 파일 연직 자동제어기 프로토타입(prototype)을 개발하는 것이다. 본 연구를 통해 제시된 PHC 파일 연직 자동제어기가 현장에 적용될 경우, PHC 파일 연직도 측정 및 제어의 자동화를 통해 품질 및 안전성 향상이 가능할 것으로 기대된다.

유리체강 내 주입술을 받는 망막질환자의 시각 관련 삶의 질 영향요인 (Factors Influencing on Vision-related Quality of Life in Patients with Retinal Diseases Receiving Intravitreal Injections)

  • 김현영;하영미
    • 임상간호연구
    • /
    • 제27권1호
    • /
    • pp.54-65
    • /
    • 2021
  • Purpose: The purpose of this study was to identify influencing factors on vision-related quality of life in patients with retinal diseases receiving intravitreal injections by examining relationships among anxiety, depression, coping, eye health behaviors and vision-related quality of life. Methods: One hundred and five outpatients who were diagnosed with macular degeneration and diabetic retinopathy were recruited from one university hospital during August 16, 2019 to March 25, 2020. Data were analyzed using descriptive statistics (frequency and percentage, mean, standard deviation), and t-tests, ANOVA, Scheffé test, Pearson's correlations, and stepwise multiple regressions using the IBM SPSS Statistics 25.0. Results: The vision-related quality of life according to general characteristics of retinal disease patients with intravitreal injection showed significant differences in age (F=3.01, p=.034), subjective economic status (F=5.83, p=.004), types of retinal disease (t=2.62, p=.010), and disease in both eyes (t=-3.04, p=.003). The vision-related quality of life showed a significant positive correlation with age (r=.24, p=.012), and negative correlations with anxiety (r=-.66, p<.001), depression (r=-.48, p<.001), and emotion-focused coping (r=-.20, p=.036). The hierarchical regression analysis indicated that factors affecting vision-related quality of life in patients with retinal diseases were anxiety and subjective economic status, accounting for 47.0% of the variances of the vision-related quality of life. Conclusion: Based on our results, health professionals need to pay attention to patients with low socioeconomic status due to frequent treatments. Also, a program needs to be developed to decrease anxiety for outpatients receiving intravitreal injections to improve their vision-related quality of life.

안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구 (Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection)

  • 서재호;최진용;오환섭;박영배;박영재
    • 대한한의진단학회지
    • /
    • 제18권2호
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

검안렌즈 표준화의 필요성과 규격에 관한 연구 (The Necessity and Requirement of Trial Lens Set Standardization)

  • 박상열
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.217-223
    • /
    • 2006
  • 본 연구를 하게 된 목적은 전국의 약 7681개의 안경업소와 안과병 의원 그리고 콘택트렌즈 전문점에서 타각적 굴절 검사를 한 후 자각적 굴절 검사를 하기 위해 사용하는 검안렌즈세트(Trial lens set)가 표준화 된 규격이 미흡하고 안광학적 허용 오차도 규정되어 있지 않고 표기된 굴절력과 실제 렌즈 도수가 상의한 것이 많아 이를 개선하고 검안렌즈 규격에 표준화를 만들고자 이 연구를 하게 되었다. 연구방법으로는 검안렌즈 세트를 사용하는 안경사들을 대상으로 보수교육을 통해 설문조사를 실시하고 국내에서 사용하는 제품과 수입 제품을 사용하는 안경원을 설정하여 이들이 사용하는 김안렌즈 세트를 사용하기에 따라 5년 미만, 5~10년, 10년 이상 각 5곳씩 검안렌즈를 선정하였으며, 표기된 굴절력과 실제렌즈를 측정하여 일본공업규격(JIS T4402)과 비교 분석하여 보았다. 분석결과를 살펴보면 검안렌즈를 사용하는 사람들이 사용 중인 접안렌즈의 굴절력에 대한 신뢰성이 응답자의 80% 이상을 차지하고 구입후 한 번도 표기된 굴절력과 실제도수를 측정해보지 않았다. 또한 한국산업규격(KS P4402)은 1979년도에 제정되어서 현재 사용하는 렌즈세트에서 빠지는 도수가 많다. 응답자의 95% 이상이 시력검사시 불편함을 느끼고 있다. 또한 굴절력에 대한 오차는 사용기간이 오래된 검안렌즈 일수록 오차가 큰 것을 알 수 있었다. 결론은 우리나라도 검안렌즈 규격을 표준화시키고 한국산업규격(KS P4402)에서 규정된 렌즈 세트에서 빠지는 도수에 대한 렌즈 세트를 추가시켜야 된다고 생각한다. 그리고 표준화된 검안렌즈를 검사 및 관리 감독하는 기관도 만들어야 한다고 생각한다. 국내에서 생산하는 제품이나 외국에서 수입되는 제품도 독일이나 일본처럼 안광학적 허용오차를 규정히여 이를 검사하고 규격에 맞는 검안렌즈 세트가 유통되기를 바란다. 국민의 안보건 향상과 시기능 관리를 위해서 정확한 시력검사를 해야 하고 누구나 똑같은 표준화된 검안렌즈 세트를 사용하고 규격과 허용오차 범위를 벗어나지 않는 검안렌즈 세트가 규정되길 바란다.

  • PDF

태양인 체형, 안면, 음성, 성격 특성 (The Characteristics of Taeyangin on Body Shape, Face, Voice and Temperament)

  • 장은수;도준형;장준수;구본초;유종향;최희석;이시우
    • 사상체질의학회지
    • /
    • 제25권3호
    • /
    • pp.145-157
    • /
    • 2013
  • Objectives This study was aimed to reveal the characteristics of the body shape, face, voice and temperament in Taeyangin. Methods The subjects were recruited from November 2005 to August 2012. Sasang constitutional specialist in each clinics confirmed the Sasang Constitution. Taeyangin (TY) became a standard guidance to be compared with each other Sasang type. Anova test was used in analyzing continuous variables and factor analysis was conducted in temperament questionnaire in advance. Generalized propensity score with age and body mass index (BMI) was used in adjusted model. Significant level was .05 Results 1. The TY body shape were generally smaller than Taeeumin (TE) (p<0.001) and Soyangin (SY) (p<0.05) in crude. The TY body shape were still smaller than TE (p<0.05) and there was no significant difference between TY and SY except rib circumference in males and forehead circumference (p<0.05) in females in adjusted model. 2. The size of face and nose in TY was smaller than in TE and there was different between males and females' TY and others in the characteristics of eye, nose and forehead variables in crude (p<0.05). Most of differences between TY and TE were disappeared in adjusted model. 3. The vocal height and speed of TY was different other types and there was different between males and females' TY in some of frequency change rate in crude (p<0.05). Most of differences between TY and other types were similar before and after adjusted model. 4. The temperament of TY was different with SE before and after adjusted mode 1 (p<0.05). TY males showed difference in expression factor and TY females showed difference in behavior factor compared with TE respectively (p<0.05). Conclusions This study reveals characteristics of body shape, face, voice and character in the TY males females compared with each other type respectively.