• Title/Summary/Keyword: Korean Oncology

Search Result 6,315, Processing Time 0.039 seconds

Magnetic Resonance Imaging Factors Predicting Re-excision in Breast Cancer Patients Having Undergone Conserving Therapy (유방보존술을 시행받는 유방암환자에서 재절제 예측의 자기공명영상소견)

  • Jang, Mijung;Kim, Sun Mi;Yun, Bo La;Kim, Sung-Won;Kang, Eun Young;Park, So Yeon;Kim, Jee Hyun;Kim, Yeongmi;Ahn, Hye Shin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.133-143
    • /
    • 2014
  • Purpose : The aim of this study was to determine the magnetic resonance imaging (MRI) features associated with re-excision due to the presence of a positive margin after breast conserving therapy (BCT) in breast cancer patients. Materials and Methods: We reviewed the records of 286 consecutive breast cancer patients who received BCT between January 2006 and December 2007. Among 246 patients who had undergone BCT, 38 (15.4%) underwent immediate further surgery due to positive margin status. We analyzed the MRI findings using ${\chi}^2$ test, Fisher's exact test and t tests. Multivariate logistic regression was conducted for prediction of re-excision. Results: Tumor size (p < 0.001), lesion multiplicity (p = 0.003), and non-mass-like enhancement (NMLE) type on MRI (p < 0.001) were associated with margin involvement in BCT. On preoperative MRI, larger size (${\geq}5cm$) (odds ratio = 2.96), NMLE (odds ratio = 3.81), and multifocal lesions (odds ratio = 2.54) were positively associated with re-excision. In cases involving NMLE, segmental distribution was associated with a greater likelihood of immediate re-excision. Conclusion: Larger size, multiplicity, and NMLE on MRI are significantly associated with re-excision after BCT in breast cancer patients. For NMLE lesions, the segmental distribution pattern was predictive of re-excision.

Differentiation of True Recurrence from Delayed Radiation Therapy-related Changes in Primary Brain Tumors Using Diffusion-weighted Imaging, Dynamic Susceptibility Contrast Perfusion Imaging, and Susceptibility-weighted Imaging (확산강조영상, 역동적조영관류영상, 자화율강조영상을 이용한 원발성 뇌종양환자에서의 종양재발과 지연성 방사선치료연관변화의 감별)

  • Kim, Dong Hyeon;Choi, Seung Hong;Ryoo, Inseon;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.120-132
    • /
    • 2014
  • Purpose : To compare dynamic susceptibility contrast imaging, diffusion-weighted imaging, and susceptibility-weighted imaging (SWI) for the differentiation of tumor recurrence and delayed radiation therapy (RT)-related changes in patients treated with RT for primary brain tumors. Materials and Methods: We enrolled 24 patients treated with RT for various primary brain tumors, who showed newly appearing enhancing lesions more than one year after completion of RT on follow-up MRI. The enhancing-lesions were confirmed as recurrences (n=14) or RT-changes (n=10). We calculated the mean values of normalized cerebral blood volume (nCBV), apparent diffusion coefficient (ADC), and proportion of dark signal intensity on SWI (proSWI) for the enhancing-lesions. All the values between the two groups were compared using t-test. A multivariable logistic regression model was used to determine the best predictor of differential diagnosis. The cutoff value of the best predictor obtained from receiver-operating characteristic curve analysis was applied to calculate the sensitivity, specificity, and accuracy for the diagnosis. Results: The mean nCBV value was significantly higher in the recurrence group than in the RT-change group (P=.004), and the mean proSWI was significantly lower in the recurrence group (P<.001). However, no significant difference was observed in the mean ADC values between the two groups. A multivariable logistic regression analysis showed that proSWI was the only independent variable for the differentiation; the sensitivity, specificity, and accuracy were 78.6% (11 of 14), 100% (10 of 10), and 87.5% (21 of 24), respectively. Conclusion: The proSWI was the most promising parameter for the differentiation of newly developed enhancing-lesions more than one year after RT completion in brain tumor patients.

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

Bloodstream Infections in Children with Cancer between 2005 and 2008 in a Single Center (2005-2008년 단일 기관의 소아 혈액 종양 환자에서의 균혈증 양상: 소아 혈액 종양 환자에서의 균혈증)

  • Kim, Ji Hye;Kim, Hyung Jin;Lim, Yeon Jung;Lee, Young Ho;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.1
    • /
    • pp.36-48
    • /
    • 2010
  • Purpose : In children on anticancer chemotherapy, bloodstream infections (BSIs) are a major cause of morbidity and mortality. We investigated febrile episodes and bloodstream infections in pediatric cancer patients to guide proper selection of empiric antibiotics for febrile pediatric hemato-oncologic patients. Methods : All febrile episodes treated in the division of hematology-oncology, the department of pediatrics, Hanyang University Hospital, between July 2005 and June 2008 were reviewed. Episodes with and without bloodstream infections were compared. Results : Forty cases (18.9%, 25 patients) of BSI occurred in 212 febrile episodes (63 patients). Thirty-seven cases (23.6%, 22 patients) of BSI occurred in 157 febrile episodes with neutropenia (54 patients). Microorganisms identified in BSI corresponded to 23 gram-positive bacteria (51.2%), 20 gram-negative bacteria (44.5%), and 2 fungi (4.4%). Rates of BSI between those who had received umbilical cord blood transplantation and those who had received transplantation from other source were significantly different (55.0% vs. 7.7%, P =0.001). No differences in mortality rate were observed among organisms in BSI patients. For febrile episodes the rate of BSI was higher among those with Chemoport than those with Hickman catheter (P =0.029) and gram-positive pathogens were more likely to be associated with Chemoport (P =0.001). Conclusion : The study showed the rate of BSI, distribution of pathogens with regard to neutropenia, transplantation, central venous catheters, and antimicrobial susceptibility of pathogens in order to help guide in the choice of optimal empiric antibiotics in pediatric febrile neutropenic hemato-oncologic patients.

The Caspase-3 and c-myc Expressions in Completely Resected Non-small Cell Lung Cancer and Its Prognostic Significance (완전 절제된 원발성 비소세포 폐암에서 Caspase-3와 c-myc 단백의 발현과 임상 예후)

  • Cho, Deog-Gon;Cho, Kyu-Do;Kang, Chul-Ung;Jo, Min-Seop;Yoo, Jin-Young;Ahn, Myeong-Im;Kim, Chi-Hong;Shim, Byoung-Yong;Kim, Sung-Whan;Kim, Hoon-Kyo
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.447-456
    • /
    • 2008
  • Background: Caspase-3 is a cysteine protease that plays a major role in the process of apoptotic cell death. The dysregulated expression of c-myc contributes to the tumorigenesis in a variety of human cancers. The aim of this study was to investigate the expressions of caspase-3 and c-myc and their significances as prognosis markers in patients with completely resected non-small cell lung cancer (NSCLC). Material and Method: A total 130 consecutive patients who had undergone complete resection without pre-operative radio-therapy or chemotherapy between May 1996 and December 2003 for NSCLC were retrospectively reviewed. The median follow-up period of the patients was 50 months (range: $3{\sim}128$ months). The expressions of caspase-3 and c-myc were immuno-histochemically examined, and these were correlated with the clinico-pathologic data. Result: The prevalence of caspase-3 and c-myc expressions in the patients was 68% (88/130) and 59% (77/130), respectively. Significant association was found between the frequency of the expressions of caspase-3 and c-myc (p=0.025). The caspase-3 and c-myc expressions were not significantly associated with the prognosis in all the patients. However, according to stages, a positive caspase-3 expression was significantly correlated with a favorable prognosis for patients with stage IIIa disease (median survival period: 35 months vs. 10 months, p=0.021). Multivariate analysis showed the pathologic stage to be significantly correlated with a good prognosis in all the patients (p=0.024), and with a positive caspase-3 expression, well differentiated tumor and negative neuronal invasion in the patients with stage llla disease (p=0.005, p=0.003, p=0.004, respectively). Conclusion: Caspase-3 and c-myc were frequently expressed in NSCLC, suggesting its possible involvement in tumor development. The caspase-3 expression, as determined with performing immunohistochemical staining, may be a favorable prognostic indicator in patients with completely resected NSCLC an advanced stage (IIIa).

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

An Effect of Time Gating Threshold (TGT) on the Delivered Dose at Internal Organ with Movement due to Respiration (호흡에 의해 내부 움직임을 갖는 장기에 전달되는 선량에서 Time Gating Threshold (TGT)의 효과)

  • Kim Yon Lae;Chung Jin Bum;Chung Won Kyun;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2005
  • In this study, we investigated the effect of time gating threshold on the delivered dose at a organ with internal motion by respiration. Generally, the internal organs have minimum motion at exhalation during normal breathing. Therefore to compare the dose distribution time gating threshold, in this paper, was determined as the moving region of target during 1 sec at the initial position of exhalation. The irradiated fields were then delivered under three conditions; 1) non-moving target 2) existence of the moving target in the region of threshold (1sec), 3) existence of the moving target region out of threshold (1.4 sec, 2 sec). And each of conditions was described by the moving phantom system. It was compared with the dose distributions of three conditions using film dosimetry. Although the treatment time increased when the dose distributions was obtained by the internal motion to consider the TGT, it could be obtained more exact dose distribution than in the treatment field that didn't consider the internal motion. And it could be reduced the unnecessary dose at the penumbra region. When we set up 1.4 sec of threshold, to reduce the treatment time, it could not be obtained less effective dose distribution than 1 sec of threshold. Namely, although the treatment time reduce, the much dose was distributed out of the treatment region. Actually when it is treated the moving organ, it would rather measure internal motion and external motion of the moving organ than mathematical method. If it could be analyzed the correlation of the internal and external motion, the treatment scores would be improved.

  • PDF

Ototoxicity in children receiving cisplatin chemotherapy (Cisplatin을 포함한 항암치료를 받은 소아에서 이독성)

  • Jang, Hee Jin;Cho, Hyung Rae;Lee, Jae Hee;Bae, Kun Yuk;Seo, Jong Jin;Moon, Hyung Nam;Im, Ho Joon
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.2
    • /
    • pp.210-214
    • /
    • 2010
  • Purpose : Cisplatin is highly effective for the treatment of solid tumors in children. However, the clinical use of cisplatin is limited by its ototoxicity. The aim of this study was to evaluate the ototoxicity in children treated with cisplatin. Method : We performed a single institution retrospective analysis of pediatric oncology patients who received cisplatin therapy between January 2001 and January 2008. Thirty-seven patients with sufficient medical and audiologic data were included in this study. Results : The median age at the time of diagnosis was 10.7 (range 3.8-6.7) years. There were 16 males and 21 females. The underlying diseases were osteosarcoma (15 cases), medulloblastoma (14 cases), germ cell tumors (7 cases), and hepatoblastoma (1 case). The median individual dose was $100mg/m^2$/cycle (56-200). The median cumulative dose was $480mg/m^2$ (200-1,490). Sixteen patients (43%) received cranial radiotherapy. Of the 37 patients, 17 developed hearing loss, leading to an overall incidence of 46%. Logistic regression showed that age at treatment (P =0.04) and cumulative dose of cisplatin (P =0.005) were the significant risk factors in predicting hearing loss in children treated with cisplatin. In all the patients who had hearing loss, there was neither improvement nor aggravation during the follow-up (3-8 months). Conclusion : The cumulative dose of cisplatin (>$500mg/m^2$) and younger age at treatment (<12 years) were 2 most important risk factors for ototoxicity in patients treated with cisplatin. Serial audiometric evaluations are needed in the patients with risk factors during and after cisplatin treatment.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF