• Title/Summary/Keyword: Knife radiosurgery

Search Result 163, Processing Time 0.033 seconds

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

An Image-guided Radiosurgery for the Treatment of Metastatic Bone Tumors using the CyberKnife Robotic System

  • Cho, Chul-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2007
  • Bone is a common site for metastatic spread from many kinds of malignancies. The morbidity associated with this metastatic spread can be significant, including severe pain. When it comes to spinal metastasis, occupying nearly 40% of skeletal metastases, the risks of complications, such as vertebral body collapse, nerve root impingement, or spinal cord compression, are also significant. Because of the necessity of preserving the integrity of the spinal column and the proximity of critical structures, surgical treatment has limitations when durable local control is desired. Radiotherapy, therefore, is often used as an adjunct treatment or as a sole treatment. A considerable limitation of standard radiotherapy is the reported recurrence rate or ineffective palliation of pain, either clinically or symptomatically. This may be due to limited radiation doses to tumor itself because of the proximity of critical structures. CyberKnife is an image-guided robotic radiosurgical system. The image guidance system includes a kilovoltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator (6 MV) mounted on a robotic arm. Highly conformal fields and hypofractionated radiotherapy schedules are increasingly being used as a means to achieve biologic dose escalation for body tumors. Therefore, we can give much higher doses to the targeted tumor volume with minimizing doses to the surrounding critical structures, resulting in more effective local control and less severe side effects, compared to conventional fractionated radiotherapy. A description of this technology and a review of clinical applications to bone metastases are detailed herein.

  • PDF

Cavernous Angioma : Natural History and Management Strategies (해면상 혈관종의 자연 경과와 치료 전략)

  • Lim, Hyo Joo;Kwon, Yang;Ahn, Jae Sung;Kim, Jeong Hoon;Kim, Chang Jin;Lee, Jung Kyo;Kwun, Byung Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1001-1007
    • /
    • 2000
  • Objective : We analysed diverse clinical features of the cavernous angioma. Also, we report the experience in differ-ent methods of the management and their results. Method : Data from 80 patients who were confirmed pathologically or diagnosed radiologically between Jan. 1990 and Sept. 1998 at our hospital were analysed. Variable factors that were examined were : clinical features, effects of treatment, and complications. Results : There were 47 male and 33 female patients. The age at the first presentation was from 3 to 57(mean 34.1) years old. Clinical features were seizure in 28 cases(38%), bleeding in 24 cases(32%), neurologic deficits in 12 cases(16%), headache in 10 cases(14%), and six incidental cases. The locations of lesion were cerebral and cerebellar hemisphere in 45 cases(56.2%), brainstem, basal ganglia, and thalamus in 32 cases(40%), multiple in 3 cases (3.8%). Seizure was common at the third decade and occurred frequently with the cavernous angioma in temporal (43%) or frontal lobe(39%). Bleeding was frequent after the third decade with peak at the fourth decade and had high incidence in brainstem or thalamus. The gamma-knife radiosurgery was done in 47 cases. Rebleeding occurred in 3 cases, but it was within postradiosurgery 1 year. Symptomatic radiation change occurred in 2 cases of 8 radiation change on MRI. On follow-up MRI, no evidence of rebleeding was found in 30 cases. Also, The lesion size was decreased in 3 cases. Resection was performed in 23 cases ; total 20, subtotal 2, partial 1. Postoperative complication occurred in 6 cases(26.1%). After surgery, 7(63.6%) of 11 seizure patients had outcome of seizure-free. Subclinical rebleeding occurred in one of two subtotal resected cases. In 11 patients, conservative management was done. There was neither rebleeding nor symptom aggravation during follow-up period of mean 17.2 months. Conclusion : The solution for prevention of rebleeding is complete removal of the lesion located at noneloquent area or accessible region, especially for the patients who presented symptoms or intractable seizure. However, the Gamma knife radiosurgery is considered when the lesions are located at eloquent area or when severe postoperative morbidity is expected.

  • PDF

Selective Beam Shielding Method of Gamma-Knife Unit Using Various Plugging Patterns (다양한 Plugging 형태를 이용한 감마나이프의 선택적 빔 차폐 방법)

  • Jang Geon Ho;Lim Young Jin;Shin Dong Oh;Choi Doo Ho;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.439-448
    • /
    • 1993
  • The B-type gamma knife unit was installed at Kyung-Hee University Hospital in March 1992. The selective beam plugging method can be used to reduce the low percentage isodose profiles of normal sensitive organ and to modify the isodose curves of treatment volume for better shaping of the target volume. For representing the changes of the low percentage isodose profiles, the variations of dose distribution for several cases were discussed in this paper. The film dosimetry was peformed for the evaluation of calculated isodose profiles predicted by KULA dose planning system. The results were verified by RFA-3 automatic densitometry. The clinical application of selective beam shielding method was peformed in 17 patients in 100 patients who have undergone gamma knife radiosurgery for a year. The calculated and the measured isodose profiles for the high percentage regions were well consistent with each other. When the target of pituitary tumor is macro-size, the selective beam shielding method is the most applicable method. When the target size, however, is small, the correct selection of the proper helmet size is very important. All patients were exposed almost about 3~12 Gy for brain stem, and 3~11.2 Gy for optic apparatus. It is recommended that the same or other plugging patterns with multiple isocenters should be used for protection of the radiosensitive normal structures with precise treatment of CNS lesions.

  • PDF

Reliability of Stereotactic Coordinates of 1.5-Tesla and 3-Tesla MRI in Radiosurgery and Functional Neurosurgery

  • Kim, Hae Yu;Lee, Sun-Il;Jin, Seong Jin;Jin, Sung-Chul;Kim, Jung Soo;Jeon, Kyoung Dong
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.136-141
    • /
    • 2014
  • Objective : The aims of this study are to identify interpersonal differences in defining coordinates and to figure out the degree of distortion of the MRI and compare the accuracy between CT, 1.5-tesla (T) and 3.0T MRI. Methods : We compared coordinates in the CT images defined by 2 neurosurgeons. We also calculated the errors of 1.5T MRI and those of 3.0T. We compared the errors of the 1.5T with those of the 3.0T. In addition, we compared the errors in each sequence and in each axis. Results : The mean difference in the CT images between the two neurosurgeons was $0.48{\pm}0.22mm$. The mean errors of the 1.5T were $1.55{\pm}0.48mm$ (T1), $0.75{\pm}0.38$ (T2), and $1.07{\pm}0.57$ (FLAIR) and those of the 3.0T were $2.35{\pm}0.53$ (T1), $2.18{\pm}0.76$ (T2), and $2.16{\pm}0.77$ (FLAIR). The smallest mean errors out of all the axes were in the x axis : 0.28-0.34 (1.5T) and 0.31-0.52 (3.0T). The smallest errors out of all the MRI sequences were in the T2 : 0.29-0.58 (1.5T) and 0.31-1.85 (3.0T). Conclusion : There was no interpersonal difference in running the Gamma $Plan^{(R)}$ to define coordinates. The errors of the 3.0T were greater than those of the 1.5T, and these errors were not of an acceptable level. The x coordinate error was the smallest and the z coordinate error was the greatest regardless of the MRI sequence. The T2 sequence was the most accurate sequence.

Upfront Stereotactic Radiosurgery for Pineal Parenchymal Tumors in Adults

  • Park, Jong Hoon;Kim, Jeong Hoon;Kwon, Do Hoon;Kim, Chang Jin;Khang, Shin Kwang;Cho, Young Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.334-340
    • /
    • 2015
  • Objective : Pineal parenchymal tumors (PPTs) in adults are rare, and knowledge regarding their optimal management and treatment outcome is limited. Herein, we present the clinical results of our series of PPTs other than pineoblastomas managed by stereotactic radiosurgery (SRS) at upfront setting. Methods : Between 1997 and 2014, nine consecutive adult patients with the diagnosis of PPTs, either pineocytoma or pineal parenchymal tumor of intermediate differentiation, were treated with SRS. There were 6 men and 3 women. The median age was 39 years (range, 31-53 years). All of the patients presented with symptoms of hydrocephalus. Endoscopic third ventriculostomy and biopsy was done for initial management. After histologic diagnosis, patients were treated with Gamma Knife with the mean dose of 13.3 Gy (n=3) or fractionated Cyberknife with 32 Gy (n=6). Results : After a mean follow-up of 78.6 months (range, 14-223 months), all patients were alive and all of their tumors were locally controlled except for one instance of cerebrospinal fluid seeding metastasis. On magnetic resonance images, tumor size decreased in all patients, resulting in complete response in 3 patients and partial response in 6. One patient had experienced temporary memory impairment after SRS, which improved spontaneously. Conclusion : SRS is effective and safe for PPTs in adults and can be considered as a useful alternative to surgical resection at upfront setting.

Stereotactic Radiosurgery for Dural Arteriovenous Fistulas Involving the Transverse-Sigmoid Sinus : A Single Center Experience and Review of the Literatures

  • Baek, Hong-Gyu;Park, Seong-Hyun;Park, Ki-Su;Kang, Dong-Hun;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.458-466
    • /
    • 2019
  • Objective : We retrospectively assessed the efficacy of stereotactic radiosurgery (SRS) for dural arteriovenous fistulas (DAVFs) involving the transverse-sigmoid sinus and analyzed the angiographic and clinical results with our 8-year experience. Methods : Nine patients with intracranial DAVFs involving the transverse-sigmoid sinus underwent SRS using a Gamma $Knife^{(R)}$ (Elekta Inc., Atlanta, GA, USA) between 2009 and 2016. Five patients underwent SRS for residual DAVFs after embolization and four patients were treated with SRS alone. The median target volume was $1.9cm^3$ (range, 0.8-14.2) and the median radiation dose of the target was 17 Gy (range, 16-20). The median follow-up period was 37 months (range, 7-81). Results : Pulsating tinnitus (33%) was the most common symptom. DAVFs were completely obliterated in four patients (44%) and subtotally obliterated in five (56%). Six patients (67%) showed complete recovery of symptoms or signs, and three (33%) showed incomplete recovery. One patient experienced a recurrent seizure. Adverse radiation effects after SRS occurred in one patient (11%). The total obliteration rates after SRS were 16.7%, 37.5%, and 68.7% at 1, 2, and 3 years, respectively. The median interval from SRS to total obliteration of the fistula was 31 months (range, 12-38). The rates at which the symptoms started to improve were 40% at 1 month and 80% at 2 months after SRS. Symptoms started to improve at a median of 5 weeks after SRS (range, 3-21). Conclusion : SRS with or without embolization is a safe and effective treatment to relieve symptoms and obliterate DAVFs on the transverse-sigmoid sinus.

Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer (원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과)

  • Kim, Woo-Chul;Kim, Hun-Jung;Park, Jeong-Hoon;Huh, Hyun-Do;Choi, Sang-Huoun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.28-35
    • /
    • 2011
  • Purpose: Recently, the use of radiosurgery as a local therapy in patients with early stage non-small cell lung cancer has become favored over surgical resection. To evaluate the efficacy of radiosurgery, we analyzed the results of stereotactic body radiosurgery in patients with primary or recurrent non-small cell lung cancer. Materials and Methods: We reviewed medical records retrospectively of total 24 patients (28 lesions) with non-small cell lung cancer (NSCLC) who received stereotactic body radiosurgery (SBRT) at Inha University Hospital. Among the 24 patients, 19 had primary NSCLC and five exhibited recurrent disease, with three at previously treated areas. Four patients with primary NSCLC received SBRT after conventional radiation therapy as a boost treatment. The initial stages were IA in 7, IB in 3, IIA in 2, IIB in 2, IIIA in 3, IIIB in 1, and IV in 6. The T stages at SBRT were T1 lesion in 13, T2 lesion in 12, and T3 lesion in 3. 6MV X-ray treatment was used for SBRT, and the prescribed dose was 15~60 Gy (median: 50 Gy) for PTV1 in 3~5 fractions. Median follow up time was 469 days. Results: The median GTV was 22.9 mL (range, 0.7 to 108.7 mL) and median PTV1 was 65.4 mL (range, 5.3 to 184.8 mL). The response rate at 3 months was complete response (CR) in 14 lesions, partial response (PR) in 11 lesions, and stable disease (SD) in 3 lesions, whereas the response rate at the time of the last follow up was CR in 13 lesions, PR in 9 lesions, SD in 2 lesions, and progressive disease (PD) in 4 lesions. Of the 10 patients in stage 1, one patient died due to pneumonia, and local failure was identified in one patient. Of the 10 patients in stages III-IV, three patients died, local and loco-regional failure was identified in one patient, and regional failure in 2 patients. Total local control rate was 85.8% (4/28). Local recurrence was recorded in three out of the eight lesions that received below biologically equivalent dose 100 $Gy_{10}$. Among 20 lesions that received above 100 $Gy_{10}$, only one lesion failed locally. There was a higher recurrence rate in patients with centrally located tumors and T2 or above staged tumors. Conclusion: SBRT using a CyberKnife was proven to be an effective treatment modality for early stage patients with NSCLC based on high local control rate without severe complications. SBRT above total 100 $Gy_{10}$ for peripheral T1 stage patients with NSCLC is recommended.

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

A case report of a patient with squamous cell carcinoma of the face irradiated using a stereotactic technique

  • Pontoriero, Antonio;Iati, Giuseppe;Pergolizzi, Stefano
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.261-264
    • /
    • 2015
  • External beam radiotherapy can be used to treat cutaneous squamous cell carcinomas (SCC). Acute skin toxicity is the most common adverse event. In this case study we report on an elderly patient with nasal root cutaneous SCC treated with stereotactic technique using a dedicated linear accelerator (CyberKnife system). Grade 3 skin toxicity was observed but it was resolved after 6 weeks. The use of stereotactic radiotherapy permitted a clinical remission of SCC with good cosmetic results.