• Title/Summary/Keyword: Knee joint capsule

Search Result 20, Processing Time 0.036 seconds

A Comparative Study About the Effect of Nonablative Laser and Thermal energy on Rabbit Knee Joint Capsular Properties (비융해성 LASER 및 열에너지의 가토 슬관절막에 대한 영향 비교)

  • Byun Ki-Yong;Rhee Kwang-Jin;Lee Jun-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • Purpose: To evaluate the histologic effect(LM and EM findings)of nonablative LASER and thermal energy on knee joint capsule of rabbit. Material and Methods: The nonablative LASER and thermal energy was applied to the rabits(average age 36 weeks, weight 5 ㎏). There were divided into 4 groups with 6 rabbits in each. The group I received 6 watts of LASER, group Ⅱ 12 watts of LASER, group Ⅲ 60° of thermal energy, and group Ⅳ 70° of thermal energy. The histologic study included H-E, Massons trichrome stain and electron microscopy at immediate, 3 weeks and 6 weeks after operation. Results: The histologic finding in immediate after operation was shown a fibrous degeneration of collagen on all groups and related to the energy level. The histologic finding after 3 weeks showed fibrosis and this fibrosis related the level of energy. Especially the group IV was shown flattening of capsule and deep fibrosis. The histologic finding after 6 weeks was shown marked recovery of collagen arrangement and capillary proliferation in group Ⅰ,Ⅱ and Ⅲ. But in the group Ⅳ not recovered. Conclusion: The nonablative LASER or thermal energy can cause degeneration, fibrosis and contracture of joint capsular collagen.

  • PDF

Arthroscopic Repair of the Postero-medial or Postero-lateral Capsule Tear in the Knee Joint - Technical Note - (슬관절 후내측 혹은 후외측 관절막 파열의 관절경적 봉합술 - 수술 수기 -)

  • Ahn Jin-Hwan;Cho Yang-Bum;Lee Yong-Seuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.135-139
    • /
    • 2001
  • Purpose : Repair of the posterior capsule tear at the time of the operation for the chronic postero-lateral or postero-medial rotary instability has not been reported. We describe the arthroscopic repair of the posterior capsule tear using the posterior trans-septal portal. Method : After conducting basic arthroscopic examination of the knee, postero-medial and postero-lateral portals are secure to make the posterior trans-septal portal, through which the postero-medial and postero-lateral capsule tears are repaired using the suture hook under the arthroscopic guidance. Conclusion : When arthroscopic reconstruction of PCL insufficiency or postero-lateral rotaty instability that accompanies postero-medial or postero-lateral capsular tears. rising the posterior traits-septal portal could ensure better visualization of the capsule and a subsequent more accurate repair of the capsule. Since it significantly lessened instability, it could contribute to an achievement of successful clinical results.

  • PDF

Clinical Application and Limitations of the Capsular Pattern (관절낭 패턴의 임상적 적용과 한계)

  • Lim, Wootaek
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.13-17
    • /
    • 2021
  • A normal range of motion is essential for performing activities of daily living. The capsular pattern is the proportional motion restriction in range of motion during passive exercises due to tightness of the joint capsule. Although the capsular pattern is widely referred to in clinical practice, there is no scientific evidence to support the concept. In this review, the appropriateness of the capsular pattern for evaluation of joint pathology was assessed. In the Textbook of Orthopaedic Medicine written by Cyriax, the capsular pattern did not specify how much reduction in angular motion is considered motion restriction. As the definition proposed initially was unclear, different methods have been used in previous studies investigating capsular pattern. In addition, the capsular pattern described all the major joints of the human body, but only the hip joint, knee joint, and shoulder joint were studied in experimental studies. Sensitivity and specificity were reported in one study and were meaningful in specific pathologies (loss of extension to loss of flexion). There was no consensus on the reliability and validity. In summary, the capsular pattern suggested by Cyriax or Kaltenborn is not supported or applies only to certain conditions. Various components around a joint complement each other and provide stability to the joint. It is recommended that the therapist perform multiple assessments rather than rely on a single assessment when evaluating joints.

The Effects of Swimming and Low Power Laser on the Concentration of Interleukin-6 for Rheumatoid Arthritic Rats (수영과 저출력 레이저 치료가 류마티스 관절염 흰쥐의 혈청 인터루킨-6 농도에 미치는 영향)

  • Park, Mi-Hee;Rho, Min-Hee;Lee, Hyun-Ok;Koo, Bong-Oh;Hwang, Soo-Myung
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.69-76
    • /
    • 2008
  • This study was designed to determine the effects of swimming and low power laser on rheumatoid arthritis in Sprague-Dawley rats. Rheumatoid arthritis was induced in 36 rats among 48 Sprague-Dawley rats by the subcutaneous injection of .05 $m{\ell}$ Freund's Complete Adjuvant into the right hind paw and .05 $m{\ell}$ Freund's Complete Adjuvant into the right hind knee joint capsule. A second injection was performed by the same method using .1 $m{\ell}$ Freund's Complete Adjuvant per a rat. Arthritic rats were divided into 8 groups: each 1 week and 2 weeks of arthritic swimming, arthritic laser, arthritic case control and normal group. In this study, several experimental tests were performed to determine the concentration of Interleukin-6, the space of the knee joint and the thickness of the hind paw. The concentration of Interleukin-6 and hind paw thickness decreased in the swimming group and laser group as compared to the control group. The space of the knee joint increased significantly after the swimming exercise. Swimming and low power laser therapy positively affect rheumatoid arthritis in rats affect by decreasing the concentration of Interleukin-6 and hind paw thickness, and increasing the space of the knee joint.

  • PDF

A Ganglion Cyst in the Anterior Cruciate Ligament Accompanying with Discoid Lateral Meniscus - A Case Report - (원판형 외측 반월상 연골과 동반된 전방 십자 인대의 결절종 - 증례보고 -)

  • Kang, Chung-Nam;Kim, Dong-Wook;Kim, Jong-Oh;Choi, Chang-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.64-67
    • /
    • 1998
  • A ganglion cyst is a soft tissue mass that is surrounded by a dense connective-tissue capsule. The capsule is filled with a viscous fluid that is rich in hyaluronic acid and other mucopolysaccharides. But, Ganglion cysts in the knee joint are rare. There are very few case reports of ganglion cysts related to the surface of the anterior cruciate ligament, Posterior cruciate ligament and medial meniscus. We are reporting a case of a ganglion cyst in the anterior aspect of the anterior cruciate ligament accompanying with discoid lateral meniscus in the right knee of a 46-year-old woman without any history of trauma. The cyst and discoid lateral meniscus were treated successfully with arthroscopic excision and partial meniscectomy.

  • PDF

Biomechanical Analysisz of Varying Backpack Loads on the Lower Limb Moving during Downhill Walking (내림 경사로 보행시 배낭 무게에 따른 하지 움직임의 운동역학적 분석)

  • Chae, Woen-Sik;Lee, Haeng-Seob;Jung, Jae-Hu;Kim, Dong-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • Objective : The purpose of this study was to conduct biomechanical analysis of varying backpack loads on the lower limb movements during downhill walking over $-20^{\circ}$ ramp. Method : Thirteen male university students (age: $23.5{\pm}2.1yrs$, height: $175.7{\pm}4.6cm$, weight: $651.9{\pm}55.5N$) who have no musculoskeletal disorder were recruited as the subjects. Each subject walked over $20^{\circ}$ ramp with four different backpack weights (0%, 10%, 20% and 30% of body weight) in random order at a speed of $1.0{\pm}0.1m/s$. Five digital camcorders and two force plates were used to obtain 3-d data and kinetics of the lower extremity. For each trial being analyzed, five critical instants were identified from the video recordings. Ground reaction force, loading rate, decay rate, and resultant joint moment of the ankle and the knee were determined by the inverse dynamics analysis. For each dependent variable, one-way ANOVA with repeated measures was used to determine whether there were significant differences among four different backpack weight conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results : The results of this study showed that the medio-lateral GRFs at RHC in 20% and 30% body weight were significantly greater than the corresponding value in 0% of body weight. A consistent increase in the vertical GRFs as backpack loads increased was observed. The valgus joint movement of the knee at RTO in 30% body weight was significantly greater than the corresponding values in 0% and 10% body weight. The increased valgus moment of 30% body weight observed in this phase was associated with decelerating and stabilizing effects on the knee joint. The results also showed that the extension and valgus joint moments of the knee were systematically affected by the backpack load during downhill walking. Conclusion : Since downhill walking while carrying heavy external loads in a backpack may lead to excessive knee joint moment, damage can occur to the joint structures such as joint capsule and ligaments. Therefore, excessive repetitions of downhill walking should be avoided if the lower extremity is subjected to abnormally high levels of load over an extended period of time.

Measurement of Surface Strain on Soft Biological Tissues Using Irregular Grid Pattern (불규칙적인 격자망을 이용한 생체 연조직의 곡면변형률 측정)

  • Lee, Jun Sik;Kim, Ki Hong;Kim, Hyung Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1051-1057
    • /
    • 2013
  • In this study, an automatic surface-strain measurement system called "ASIAS-bio" has been developed. This system can be used even in cases in which it is very difficult to apply a regular grid pattern necessary for measuring surface-strain, such as curved or uneven surfaces; surfaces damaged by corrosion or contamination; or soft materials such as rubber, foam, and biological tissues. This system works independently of the measurement conditions including the material and its surface condition, grid pattern and size, grid marking method, and degree of deformation. A comparison between the strain distributions of the sheet metal parts measured by using this system and those obtained by a commercial system showed that this system was sufficiently reliable. In addition, the deformation of the swine joint capsule and human knee skin was measured by using this system to demonstrate its usefulness.

Anti-inflammation Effect of Low Intensity Laser Therapy in Collagen-induced Arthritis in Rats

  • Kim, Young-Eok;Kim, Eun-Jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.5
    • /
    • pp.870-875
    • /
    • 2011
  • Arthritis of the knee is the most common type of joint inflammatory disorder and it is associated with pain and inflammation of the joint capsule. The aim of present study was to investigate the endogenous effect of low intensity laser acupuncture on collagen-induced arthritis in rats. Forty Sprague-Dawley rats were randomly divided into normal group, arthritis group, low laser group with 10 rats in each group. Arthritis in rats was induced by subcutaneous injection of type II collagen combined with complete Freund's adjuvant. Here we investigated the effects of low intensity laser therapy in experimentally induced rat knee arthritis. To evaluate preventive and therapeutic effects of low intensity laser acupuncture on collagen-induced arthritis rats. In collagen induced arthritic rats, there was significant increase in rat paw volume and decrease in body weight increment, whereas low intensity laser therapy groups, showed significant reduction in paw volume and normal gain in body weight. The altered biochemical parameters(blood urea, serum creatinine, total proteins and acute phase proteins) in the arthritic rats were significantly brought back to near normal by the low intensity laser therapy. Therefore, low intensity laser acupuncture may be a useful treatment in the prevention and treatment of collagen-induced arthritis.

The Effect of Knee Flexion and Posterior Septal Release on the Location of Popliteal Artery (무릎 굴곡 및 후방 관절낭 절제술이 슬와 동맥의 위치에 주는 영향)

  • Seo, Seung-Suk;Seo, Jin-Hyuk;Kim, Chang-Wan;Kwon, Yong-Wook
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • Purpose: By confirm the change of popliteal arterial position when extension or flexion of the knee and estimate the change of popliteal arterial position after posterior capsular release, we tried to know the position can minimize injury of popliteal artery during arthroscopic surgery and usefulness of posterior capsular release. Materials and Methods: Total of two middle-aged man and woman, fresh frozen cadavers as systemic, all four cases of the knee were included in this study. After the knee was flexed to 0 degrees, 30 degrees, 60 degrees, 90 degrees angle, we estimated distance from posterior tibial cortex to popliteal artery at articular surface, the distal 1 cm and 2 cm from articular surface. We performed posterior capsular release by arthroscopy, and estimated distance between posterior tibial cortex and popliteal artery in the same way. Results: Mean distance between popliteal artery and posterior tibial cortex was 6.3 mm (4.5~7), 4.6 mm (3.6~6), 4.9 mm (3.9~5.8) when knee flexion to 0 degrees at articular surface, distal 1 cm and 2 cm from articular surface each. When knee flexion to 30 degrees, it was 7.4 mm (5.2~9), 4.9 mm (3.6~7.2), 5.3 mm (3.8~6.6). When knee flexion to 60 degrees, it was 8.7 mm (5.4~11), 5.2 mm (4.9~7.3), 6.2 mm (5.4~9.6). When knee flexion to 90 degrees, it was 9.8 mm (5.8~12.1), 5.5 mm (5.1~7.4), 6.5 mm (5.4~10.7). After posterior capsule release, the distance was 6.5 mm (5.5~7.5), 5.8 mm (3.9~7.2), 5.2 mm (3.8~7.0) when knee flexion to 0 degrees, 7.7 mm (5.5~9,1), 7.1 mm (4.6~7.6), 5.5 mm (4.1~6.9) when knee flexion to 30 degrees, 8.9 mm (5.7~11.2), 8.5 mm (5.5~9.2), 6.4 mm (5.3~10.1) when knee flexion to 60 degrees and 10.2 mm (6.3~13.6), 9.5 mm (6.5~11), 6.6 mm (5.9~9.8) when knee flexion to 90 degrees. Conclusion: As knee joint is flexed, the distance from posterial tibial cortex to popliteal artery are increased beween knee joint articular surface and distal 2 cm from knee joint. So popliteal artery injury will be reduced at knee joint surgery. Posterior capsular release could also reduce popliteal artery injury by increasing distance between posterior tibial cortex and popliteal artery.

  • PDF