• Title/Summary/Keyword: Klystron

Search Result 47, Processing Time 0.052 seconds

EPICS Based RF Control System for PAL Storage Ring (EPICS를 이용한 가속기 RF 제어시스템 개발)

  • Yoon, J.C.;Park, H.J.;Lee, J.Y.;Choi, J.Y.;Nam, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2239-2241
    • /
    • 2003
  • A new RF control system of Pohang Accelerator Laboratory (PAL) storage ring is a subsystem upgraded PAL control system, which is based upon Experimental Physics and Industrial Control System (EPICS). There are 5 control components, Low Level RF System (LRS), Klystron System, Circulator System, Cavity System, Local Cooling Water System (LCW) at the storage ring of PAL. The new RF control system for the storage ring has been under development for one years, first versions of individual VME (Versa Module Europa) Input/output modules under construction and system integration begun. In this system, VMEbus-based hardware is widely used for front-end controllers (FDS), Input/output controller (IOC). A number of Programmable Logic Controller (PLC) and SUN workstations are also used for Operator Interfaces (OPI) in the control system. This paper describes the development VME I/O module to the new control system and how the design of this new system.

  • PDF

Klystron and Modulator Controller for L-band Industrial Accelerator System (L-band 산업용 가속기 RF 증폭기의 전원장치를 위한 제어기 개발)

  • Kwon, S.J.;Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKung, W.;Jung, K.H.;Lee, K.T.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1468-1469
    • /
    • 2007
  • 포항가속기 연구소에서는 RIS 프로젝트 사업과제의 일환인 L-band 산업용 전자빔 가속기의 제작 및 기술개발 연구를 철원의 물리기술연고소 주관으로 수행하고 있다. L-band 산업용 전자빔 가속기는 전자빔에 의한 고분자개질 공정, 농수산물의 멸균 및 의료기기의 멸균 등에 적용이 가능하다. 포항가속기연구소에서는 10 MeV급 산업용 전자빔 조사장치에 적용되는 RF증폭기용 펄스 전원장치인 모듈레이터를 설계, 제작을 하였다. 펄스 전원장치인 이 모듈레이터 시스템은 평균 출력 60 kW, 펄스폭 7 us, 펄스반복율 300 Hz의 L-band 상업용 RF 증폭기 전원장치이며, RF 증폭기로 사용되는 클라이스트론은 Thales 사의 TV2022D를 사용하였다. 본 논문에서는 펄스 전원장치인 모듈레이터의 운전과 인터록을 위한 제어장치의 개발과 제작에 대하여 논하고자 한다.

  • PDF

Design Optimization of High-Voltage Pulse Transformer for High-Power Pulsed Application (고출력 펄스응용을 위한 고전압 펄스변압기 최적설계)

  • Jang, S.D.;Kang, H.S.;Park, S.J.;Han, Y.J.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1297-1300
    • /
    • 2008
  • A conventional linear accelerator system requires a flat-topped pulse with less than ${\pm}$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A pulse transformer is one of main determinants on the output pulse voltage shape. The pulse transformer was investigated and analyzed with the pulse response characteristics using a simplified equivalent circuit model. The damping factor ${\sigma}$ must be >0.86 to limit the overshoot to less than 0.5% during the flat-top phase. The low leakage inductance and distributed capacitance are often limiting factors to obtain a fast rise time. These parameters are largely controlled by the physical geometry and winding configuration of the transformer. A rise time can be improved by reducing the number of turns, but it produces larger pulse droop and requires a larger core size. By tradeoffs among these parameters, the high-voltage pulse transformer with a pulse width of 10 ${\mu}s$, a rise time of 0.84 ${\mu}s$, and a pulse droop of 2.9% has been designed and fabricated to drive a klystron which has an output voltage of 284 kV, 30-MW peak and 60-kW average RF output power. This paper describes design optimization of a high-voltage pulse transformer for high-power pulsed applications. The experimental results were analyzed and compared with the design. The design and optimal tuning parameter of the system was identified using the model simulation.

  • PDF

Characterization of the Hydrogen Reservoir for a High Power Gas Switch

  • Lee, Byeong-Jun;Park, Seong-Su;Kim, Sang-Hui;Gwon, Se-Jin;Jang, Seong-Deok;Mun, Yong-Jo;Ju, Yeong-Do;Kim, Chang-Beom;Hwang, Il-Mun;Sin, Seung-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.547-547
    • /
    • 2013
  • This paper presents the understandings carried out for the installation of the hydrogen reservoir of the multi-gap pseudospark switch under developing for the accelerator applications. As a cold cold cathode switch, the pseudospark switch could replace the thyratron switch which has hot cathode and being used well currently in the high power field such as laser and accelerator applications. Especially in the klystron modulator, the key component is a switch which mostly defines the jitter and the instability of the modulator system. To get the less jitter and the instability, we need to find proper range of the pressure for the gas discharge inside gas switch. This could be achieved by the understanding of the characteristic of the nonevaporable getter (NEG) which is used as a hydrogen reservoir for the switch. Therefore we verified the characteristics of the NEG (St 172, Saes) and its installation in the switch. Finally we controlled the getter to find best pressure point for the pseudospark switch.

  • PDF

Study of Pulse Generator used Inverter HV Power Supply (XFEL를 위한 기존의 펄스전원공급장치 개선 연구)

  • Park, S.S.;Kim, S.H.;Kim, S.C.;Hwang, J.Y.;Han, Y.J.;Chio, J.H.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2146-2148
    • /
    • 2005
  • The 2.5GeV linac of the Pohang Light Source(PLS) is planed to be converted to a XFEL. The PAL XFEL requires a new 1.2-GeV linac that will be combined to the existing linac to increase a beam energy upto 3.7GeV. This stability is mainly determined by a low level RF drive system and klystron-modulators. The stability level of the modulator has to be improved 10 times better to meet the pulse stability of 0.02 %. The regulation methods such as traditional de-Qing and precision inverter charging technology are reviewed to find out suitable upgrade scheme of the modulators. In order to obtain electron beam of the consequently stability for XFEL linac, the pulse-to-pulse beam voltage regulation is less than +/-0.5%. To get the reliable stability of the modulator which is less than +/-0.2%, a charging section is improved in a modulator which has been operated with inverter power supply and de-Q'ing.

  • PDF

Statistical analysis of failures of a medical linear accelerator over ten years (선형가속기의 10년간 관리 자료를 바탕으로 한 통계분석)

  • Ju, Sang-Gyu;Huh, Seung-Jae;Han, Young-Yih;Seo, Jeong-Min;Kim, Won-Kyou;Kim, Tae-Jong;Park, Young-Hwan
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.158-161
    • /
    • 2004
  • In order for better management of a medical linear accelerator, the records of the operational failures of Varian CL2100C over ten years were analyzed. The failures were classified according to the involved functional subunits and each class was rated into three levels depending on operational conditions. The relationship between the failure rate and working ratio was investigated. Among the recorded failures ( total 587 failures), the most frequent failure, which was 20% of the total. was observed in the parts related to the collimation system including monitor chamber. Regrading to the operational conditions, the 2nd level of failures, that temporally interrupted treatments, was the most frequent. The 3rd level of failures, that interrupted treatment for more than several hours, was mostly caused by the accelerating subunit. The average life-time of a Klystron and Thyratron became shorter as the working ratio increased, which was 42 and 83% of the expected values, respectively. Recording equipment problems and failures in detail over a long period of time can provide a good knowledge of equipment function as well as the capability to forecast future failure. More rigorous equipment maintenance is required for old medical linear accelerator to avoid the serious failure in advance, and improve the patient treatment quality.

  • PDF

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.