• 제목/요약/키워드: Kinetic Method

검색결과 1,067건 처리시간 0.033초

2상 하이브리드형 리니어 스텝핑 전동기의 미세스텝에 관한 연구 (A Study on Micro-step of 2-phase Hybrid Type Linear Stepping Motor)

  • 오홍석;김동희;이상호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.358-363
    • /
    • 2000
  • In this paper, a voltage equations, a thrust force equations and kinetic equation are derived from the basic structure of a 2-phase hybrid type linear stepping motor(HLSM). And a micro-stepping method in order to eliminate effectively the resonant phenomena and to increase the positional resolution of the HLSM was proposed. The proposed micro-stepping method can divide one step into the maximum 128 micro-steps under simple control system. The dynamic characteristics of proposed micro-stepping method were analyzed by the ACSL(Advanced Continuous Simulation Language) with the voltage equations, the thrust force equations and the kinetic equation, and were measured by laser experimental system. As the result, the justice of theory was confirmed, and the resonant phenomena, the positional resolution and dynamic thrust were improved by the proposed micro-stepping method.

  • PDF

Removal of Cu (II) from aqueous solutions using magnetite: A kinetic, equilibrium study

  • Kalpakli, Yasemen
    • Advances in environmental research
    • /
    • 제4권2호
    • /
    • pp.119-133
    • /
    • 2015
  • Water pollution means that the physical, chemical and biological properties of water are changing. In this study, adsorption was chosen as the treatment method because it is an eco-friendly and low cost approach. Magnetite is a magnetic material that can synthesize chemical precipitation. Magnetite was used for the removal of copper in artificial water samples. For this purpose, metal removal from water dependent on the pH, initial concentration of metal, amount of adsorbent and effect of sorption time were investigated. Magnetite was characterized using XRD, SEM and particle size distribution. The copper ions were determined by atomic absorption spectrometry. The adsorption of copper on the magnetite was studied in a batch process, with different aqueous solutions of Cu (II) at concentrations ranging from 10 to $50mg\;l^{-1}$. Optimum conditions for using magnetite were found to be concentration of $10mg\;L^{-1}$, pH: 4.5, contact time: 40 min. Optimum adsorbent was found to be 0.3 gr. Furthermore, adsorption isotherm data were analyzed using the Langmuir and Freundlich equations. The adsorption data fitted well with the Freundlich ($r^2=0.9701$) and Langmuir isotherm ($r^2=0.9711$) equations. Kinetic and equilibrium aspects of the adsorption process were studied. The time-dependent Cu (II) adsorption data were described well by a pseudo-second-order kinetic model.

Effect of exercise program using mirrors for stroke patients

  • Lee, Je-Hyeok;Kim, Hyun-Joo
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.60-64
    • /
    • 2013
  • This study was performed for two of specific reasons, one is for exercise development for improving stroke patient's muscle power, balance and gait and, after verifying the effect of the exercise, the other is for showing that the appling this exercise was more effective on hemi-plegic stroke patients into the clinical trial. The subjects of this study were hemi-plegic patients by stroke, 51 patients were picked up, who were agreed with this research. Close kinetic chain leg exercise using mirrors was applied to study group I, Close kinetic chain leg exercise without mirrors was applied to study group II and general physical therapy was applied to comparison group. The results of this study are as follows. The difference of the groups, study group I showed more effective than study group II on checking rectus femoris, vastus lateralis, biceps femoris, Korean version of Berg Balance Scale, Center of pressure, Functional gait assessment. In this study, Close kinetic chain leg exercise showed more effective and significant on improving for muscle power, balance and gait on stroke patients. Especially, doing exercise using mirrors is considered as more effective method than without mirrors.

Detection and Kinetics of Mucosal Pathogenic Bacteria Binding with Polysaccharides

  • Chung, Kyong-Hwan;Park, Jung-Soon;Hwang, Hyun-Soo;Kim, Jin-Chul;Lee, Ki-Young
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권7호
    • /
    • pp.1191-1197
    • /
    • 2007
  • The detection and kinetics of mucosal pathogenic bacteria binding on polysaccharide ligands were studied using a surface plasmon resonance biosensor. The kinetic model applied curve-fitting to the experimental surface plasmon resonance sensorgrams to evaluate the binding interactions. The kinetic parameters for the mucosal pathogenic bacteria (Pseudomonas aeruginosa, Pseudomonas fluorescens, Serratia marcescens) with the alginate ligand were determined from a kinetic model. In addition, the binding interactions of the mucosal pathogenic bacteria with polysaccharide binding pairs (Pseudomonas aeruginosa/alginate, Streptococcus pneumoniae/pneumococcal polysaccharide, Staphylococcus aureus/pectin) were also compared with their kinetic parameters. The rate constants of association for Pseudomonas aeruginosa with the alginate ligand were higher than those for Pseudomonas fluorescens. Serratia marcescens had no detectable interaction with the alginate ligand. The adhesion affinity of Pseudomonas aeruginosa with alginate was higher than that for the other binding pairs. The binding affinities of the pathogenic bacteria with their own polysaccharide were higher than that of Staphylococcus aureus with pectin. Measuring the contact angle was found to be a feasible method for detecting binding interactions between analytes and ligands.

Determination of the Kinetic Properties of Platy cod in D for the Inhibition of Pancreatic Lipase Using a 1, 2-Diglyceride- Based Colorimetric Assay

  • Zhao, Hai-Un;Kim, Yeong-Shik
    • Archives of Pharmacal Research
    • /
    • 제27권9호
    • /
    • pp.968-972
    • /
    • 2004
  • A 1, 2-diglyceride-based multi-step colorimetric assay to measure the pancreatic lipase activ-ity was applied for the determination of the kinetic profiles of the lipase inhibition with a slight modification and the validity verification. With this assay method, our study revealed that platy-codin D, one of major constituents of Platycodi Radix, inhibits the pancreatic lipase activity in a competitive type, with the value of $K_1$ being 0.18${\pm}$0.02 mM. In addition, PO has affected the val-ues of $K_{m}$, app/ and $K_{cat}$/$K_{m}$ in a dose-dependent manner. The results shed a meaningful light on how PO mediates lipid metabolism in the intestinal tracts. On the other hand, since the revised assay is sensitive, rapid, and does not affect the accuracy to the kinetic properties, it is applica-ble not only to evaluation of the kinetic properties of the pancreatic lipase, but also to high-throughput screening of pancreatic lipase activity.

구조물의 운동 에너지 원리에 의한 감지기의 최적 위치 (Optimal Transducer Placement Based on Kinetic Energy of the Structural System)

  • 황충열;허광희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제1권2호
    • /
    • pp.87-94
    • /
    • 1997
  • This research aims to develop an algorithm of optimal transducer placement using Kinetic Energy of the structural system. The structural vibration response-based health monitoring is considered one of the best for the system which requires a long-term, continuous monitoring. In its experimental modal testing, however, it is difficult to decide on the measurement locations and their number, especially for complex structures, which have a major influence on the quality of the results. In order to minimize the number of sensing operations and optimize the transducer location while maximizing the accuracy of results, this paper discusses about an optimum transducer placement criterion suitable for the identification of structural damage. As a criterion algorithm, it proposes the Kinetic Energy Optimization Technique (EOT), and then addresses the numerical issues which are subsequently applicable to actual experiment where a bridge model is used. By using the experimental data, it compares the EOT with the EIM (Effective Independence Method) which is generally used to optimize the transducer placement for the damage identification and control purposes. The comparison conclusively shows that the EOT algorithm proposed in this paper is preferable when a structure is to be instrumented with fewer sensors.

  • PDF

TGA를 이용한 폴리염화비닐의 연소반응에서의 열적 특성 연구 (Thermal Characteristics of Polyvinylchloride in Combustion Reaction Using TGA)

  • 서수은;강윤진;민영초;배동철;강경식
    • 대한안전경영과학회지
    • /
    • 제11권3호
    • /
    • pp.217-226
    • /
    • 2009
  • The combustion reaction of polyvinylchloride(PVC) was investigated using a thermogravimetric technique under an air atmosphere condition at several heating rates from 10 to $50^{\circ}C$/min. To obtain information on the kinetic parameters, the dynamic thermogravimetric analysis curve and its derivative were analyzed by a variety of analytical methods such as Kissinger, Friedman, Chatterjee-Conrad, Ozawa and Coats-Redfern methods. The combustion reaction of PVC proceeded in two steps; the first step was caused by the dehydrochlorination process in PVC, and the second step by the combustion of polyene. The comparative works for the kinetic results obtained from various methods should be performed to determine the kinetic parameters, because there are tremendous differences in the calculated kinetic parameters depending upon the mathematical method taken in the analysis.

Determination of the Kinetic Properties of Platycodin D for the Inhibition of Pancreatic Lipase Using a 1,2-Diglyceride-Based Colorimetric Assay

  • Zhao, Hai Lin;Kim , Yeong-Shik
    • Archives of Pharmacal Research
    • /
    • 제27권10호
    • /
    • pp.1048-1052
    • /
    • 2004
  • A 1, 2-diglyceride-based multi-step colorimetric assay to measure the pancreatic lipase activity was applied for the determination of the kinetic profiles of the lipase inhibition with a slight modification and the validity verification. With this assay method, our study revealed that platycodin D, one of major constituents of Platycodi Radix, inhibits the pancreatic lipase activity in a competitive type, with the value of $K_I$ being 0.18${\pm}$0.02 mM. In addition, PD has affected the values of $K_{m,app}\;and\;K_{cat}/K_m$ in a dose- dependent manner. The results shed a meaningful light on how PD mediates lipid metabolism in the intestinal tracts. On the other hand, since the revised assay is sensitive, rapid, and does not affect the accuracy to the kinetic properties, it is applicable not only to evaluation of the kinetic properties of the pancreatic lipase, but also to highthroughput screening of pancreatic lipase activity.

가스 하이드레이트와 파이프라인 유동 안정성 (Hydrate Researches in the flow assurance)

  • 김용헌;양성오
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.425-428
    • /
    • 2006
  • Natural gas hydrate has been a major problem for its plugging nature in the pipeline. With the demand of deep-water production, the importance of flow assurance technology, preventing hydrate, asphaltene and wax in the pipeline becomes bigger Kinetic models combined with the flow simulator are being developed to explain the nature of hydrate plug formation in the pipeline. To simulate the hydrate plug formation, each stage including the nucleation, growth and agglomeration should be considered. The hydrate nucleation is known to be stochastic and is believed hard to be predicted. Recent publications showed hydrate growth and agglomeration can be observed rigorously using a particle size analyzer. However properties of the hydrate should be investigated to model the growth and agglomeration. The attractive force between hydrate particles, supposed to be the capillary force, was revealed to be stochastic. Alternative way to model the hydrate agglomeration is to simulate by the discrete element method. Those parameters, particle size distribution, attractive force, and growth rate are embedded into the kinetic model which is combined Into the flow simulator. When compared with the flowloop experimental data, hydrate kinetic model combined into a flow simulator showed good results. With the early results, the hydrate kinetic model is promising but needs more efforts to improve it.

  • PDF

8주간 닫힌 사슬형 필라테스 운동이 하지 정렬에 미치는 영향 (Effect of an 8-week Closed Kinetic Chain Styled Pilates Exercise on Lower Limb Alignment)

  • Ga Ram Jeon;Sukhoon Yoon
    • 한국운동역학회지
    • /
    • 제33권4호
    • /
    • pp.128-136
    • /
    • 2023
  • Objective: The aim of this study was to investigate the effect of an 8-week closed kinetic chain typed Reformer and Chair Pilates exercise on static and dynamic lower limb alignment for healthy female adults. Method: Ten healthy young female adults without musculoskeletal injury history in last 6 months (Age: 29.3 ± 3.5 yrs., Height: 165 ± 3.4 cm, Body mass: 58.2 ± 5.4 kg) participated in this study. All participants asked to join the 8-week closed kinetic chain typed Reformer and Chair Pilates exercise, and the program was conducted for 60 minutes twice a week. Participants were asked to be measure a static Q-angle and performed free squat one week before and after the program. A 3-D motion analysis with 8 infrared cameras and 5 channels of EMG was executed in this study. The effectiveness of the training was evaluated by paired t-test, and the significance level was set at .05. Results: A significantly decreased in internal rotation angles was found at hip joint during free squat after the training. Also, significantly decreased in lateral rotation angles were found at knee and ankle joint during free squat after training. Finally, significantly decreased in muscle activations were found at adductor longus and peroneus longus during free squat after training. Conclusion: From results of our study, it is concluded that an 8-week closed kinetic chain typed Pilates exercise positively effect on lower limb alignment during dynamic movement.