• Title/Summary/Keyword: Key size

Search Result 1,778, Processing Time 0.033 seconds

Hierarchical Identity-Based Encryption with Constant-Size Private Keys

  • Zhang, Leyou;Wu, Qing;Hu, Yupu
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.142-145
    • /
    • 2012
  • The main challenge at present in constructing hierarchical identity-based encryption (HIBE) is to solve the trade-off between private-key size and ciphertext size. At least one private-key size or ciphertext size in the existing schemes must rely on the hierarchy depth. In this letter, a new hierarchical computing technique is introduced to HIBE. Unlike others, the proposed scheme, which consists of only two group elements, achieves constant-size private keys. In addition, the ciphertext consists of just three group elements, regardless of the hierarchy depth. To the best of our knowledge, it is the first efficient scheme where both ciphertexts and private keys achieve O(1)-size, which is the best trade-off between private-key size and ciphertext size at present. We also give the security proof in the selective-identity model.

Efficient Public Key Broadcast Encryption System (효율적인 공개키 기반의 디지털 콘텐츠 전송 시스템)

  • Lee, Moon-Shik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.635-641
    • /
    • 2010
  • In this paper, we propose an efficient public key broadcast encryption system which can also extend traitor trace and revoke system. Although the proposed system has limited collusion size, the ciphertext size in the system can be sublinear in the number of total users, the private key size is constant, the computational cost can be sublinear and it can support black-box tracing algorithm, therefore, our system can be an option to applications where reducing the ciphertext size, private key size is a top priority. Furthermore, we can also apply our system to military document broadcast system, because it has such an efficient measurement.

Effects of Solvent Size on Microscopic Structures and Properties in Polymer Solutions

  • Li, Yunqi;Shi, Tongfei;An, Lijia
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.116-117
    • /
    • 2006
  • Increasing the solvent molecular size leads to shrinkage of the polymer chains and increase of the critical overlap concentrations. In addition, the dependency of $R_{g}$ on polymer concentration under normal solvent conditions and solvent molecular size is in good agreement with scaling laws. When the solvent molecular size approaches the ideal end-to-end distance of the polymer chain, an extra aggregation of polymer chains occurs, and the solvent becomes the so-called medium-sized solvent. When the size of solvent molecules is smaller than the medium size, the polymer chains are swollen or partially swollen. However, when the size of solvent molecules is larger than the medium size, the polymer coils shrink and segregate, enwrapped by the large solvent molecules.

  • PDF

Effect of Touch-key Sizes on Usability of Driver Information Systems and Driving Safety (터치키 크기가 운전자 정보 시스템의 사용성과 운전의 안전성에 미치는 영향 분석)

  • Kim, Hee-Hin;Kwon, Sung-Hyuk;Heo, Ji-Yoon;Chung, Min-K.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.1
    • /
    • pp.30-40
    • /
    • 2011
  • In recent years, driver information systems (DIS's) became popular and the use of DIS's increased significantly. A majority of DIS's provides touch-screen interfaces because of intuitiveness of the interaction and the flexibility of interface design. In many cases, touch-screen interfaces are mainly manipulated by fingers. In this case, investigating the effect of touch-key sizes on usability is known to be one of the most important research issues, and lots of studies address the effect of touch-key size for mobile devices or kiosks. However, there is few study on DIS's. The importance of touch-key size study for DIS's should be emphasized because it is closely related to safety issues besides usability issues. In this study, we investigated the effect of touch-key sizes of DIS's while simulated driving (0, 50, and 100km/h) considering driving safety (lateral deviation, velocity deviation, total glance time, mean glance time, total time between glances, mean number of glances) and usability of DIS's (task completion time, error rate, subjective preference, NASA TLX) simultaneously. As a result, both of driving safety and usability of DIS's increased as driving speed decreased and touch-key size increased. However, there were no significant differences when touch-key size is larger than a certain level (in this study : 17.5mm).

Size control of Co-doped ZnO rods by changing the solvent

  • Zhao, Jing;Yan, Xiaoqin;Lei, Yang;Zhao, Yanguang;Huang, Yunhua;Zhang, Yue
    • Advances in materials Research
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this work, the Co-doped ZnO rods were prepared by the hydrothermal method. The size of these rods can be changed from micro-size to nano-size by using different solutions during the preparation. The results of transmission electron microscopy (TEM) and selected area electron diffraction (SAED) showed that the as-prepared nano-sized Co-doped rods have single-crystal structure. The polarized Raman experiments were presented on an individual micro-sized Co-doped ZnO rod in the $X(YY)\vec{X}$, $X(ZY)\vec{X}$ and $X(ZZ)\vec{X}$ configurations, the results of polarized Raman indicated that these rods are crystallized and their growth direction is parallel to c-axis.

Securing RTP Packets Using Per-Packet Key Exchange for Real-Time Multimedia

  • Jung, Younchan;Festijo, Enrique;Atwood, J. William
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.726-729
    • /
    • 2013
  • For secure multimedia communications, existing encryption techniques use an online session key for the key exchange, for which key size is limited to less than 10 digits to accommodate the latency condition caused by user devices only being able to handle low computational loads. This condition results in poor security of recorded encrypted data. In this letter, we propose a packet key scheme that encrypts real-time packets using a different key per packet for multimedia applications. Therefore, a key of a relatively small size can provide after-transmission confidentiality to data of a real-time session.

Usability Evaluation of the Size of Small Touch Keys for the Smart Phone (스마트 폰 터치스크린에서의 작은 터치 키의 사용성 연구)

  • Kim, Bo-Ram;Kim, Tae-Il;Lim, Young-Jae;Jung, Eui-S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.2
    • /
    • pp.80-88
    • /
    • 2012
  • This paper focuses on small touch key size and spacing that affect the usability of the smart phones. The experiments examined thirty-six different touch key designs, combinations of four touch key sizes (width (mm) ${\times}$height (mm); $4{\times}4$, $4{\times}7$, $7{\times}4$, and $7{\times}7$), and nine spacings (horizontal (mm)${\times}$vertical (mm); $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, and $3{\times}3$). Forty participants volunteered in the experiment. The completion time, error rate, identification discomfort, and control discomfort were measured. The results revealed that the touch key sizes of $7{\times}7$ and $7{\times}4$ provide the best performance in terms of the error rate measure, while the touch key size of $7{\times}7$ provides the best results for other measures. In addition, touch key spacings of $1{\times}1$, $1{\times}3$ and $3{\times}1$ are regarded as the best for all the measures. The results of this study suggest a practical approach for the small touch key design for the smart phones.

Usability Evaluation of the Touch Keys for the Smart Watch (스마트 워치 터치스크린에서의 터치 키에 대한 사용성 연구)

  • Kim, Su Young;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • The smart watch is the most popular wearable computing device because it takes a form of wristwatch. Many smart watches have adopted the touch screen interface due to the limited size of display. This paper focuses on touch key size and spacing that affect the usability about the touch key of smart watch. The experiments were made for four touch key sizes (width${\times}$height; $5{\times}5$, $5{\times}7$, $7{\times}5$, $7{\times}7mm$) and nine touch key spacing (vertical${\times}$horizontal; $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, $3{\times}3mm$). The completion time, error rate, control discomfort and identification discomfort were measured. The touch key size $7{\times}7$, $7{\times}5$ and the touch key spacing $3{\times}3$, $1{\times}3$ provided the best results in terms of the completion time and the control discomfort, while the square touch key ($7{\times}7$, $5{\times}5$) provided the best performance for the error rate measure. The result of this study can help ergonomically design the touch interface of the smart watch.

Study on the size reduction factor of extreme wind pressure of facade cladding of high-rise buildings with square section

  • Xiang Wang;Yong Quan;Zhengwei Zhang;Ming Gu
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.41-60
    • /
    • 2023
  • The effect of cladding panel size on the size reduction factor (SRF) of extreme area-averaging wind pressure (EAWP) on the facades of a high-rise building is often ignored in previous studies. Based on wind tunnel tests, this study investigated the horizontal and vertical correlations of wind pressure on the facade claddings of square-section high-rise buildings. Then, the influencing parameters on the SRF of the EAWP on the cladding panels were analyzed, which were the panel area, panel width, panel length and building width. The results show clear regional distinctions in the correlation of wind pressures on the building facades and the rules of the horizontal and vertical correlations are remarkably different, which causes the cladding size ratio to impact the SRF significantly. Therefore, this study suggests the use of the non-dimensional comprehensive size parameter b𝜶h1-𝜶/B (𝜶 is the fitting parameter) determined by the cladding panel horizontal size b, cladding panel vertical size h and the building width B rather than the cladding panel area to describe the variation of the EAWP. Finally, some empirical formula for the SRF of the EAWP on the cladding of a high-rise building is proposed with the nondimensional comprehensive size parameter.

The Influence of the Initial Spot Size of a Double Half-Gaussian Hollow Beam on Its Propagation Characteristics in a the Turbulent Atmosphere

  • Yuan, Dong;Shu-Tao, Li;Jia-Yin, Guan;Xi-He, Zhang;Guang-Yong, Jin
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.541-546
    • /
    • 2016
  • In this paper, by using the Rayleigh-Sommer field theory and the cross-spectral density function, the analytical expression for the intensity distribution of a double half-Gaussian hollow beam in a turbulent atmosphere is obtained. The influence of the initial spot size of this beam on its propagation properties in a turbulent atmosphere is simulated, and the intensity distributions for such beams with different spot sizes are obtained. The results show that the initial spot size has an important influence on the propagation properties in the near field, while this influence in the far field is very weak.