• 제목/요약/키워드: Kaolin Contaminants

검색결과 13건 처리시간 0.032초

Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성 (A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents)

  • 박재준;송일근;이재봉;천성남
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

카올린 오손물 누적량 및 누설전류 변화에 관한 연구 (A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation)

  • 박재준;송일근;이재봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • 이병성;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

HF-CT센서를 이용한 고분자애자의 오손특성 (Contamination Characteristics of Polymer Insulator using High Frequency Current Transformer)

  • 박재준
    • 정보학연구
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2005
  • Investigations of high frequency current transformer(HF-CT) waveform characteristics of the surface leakage on kaolin polluted EPDM polymer insulators have been performed. This work is part of a program aimed at examining the potential for HF-CT waveform characteristics analysis to provide information about the environment contaminants and environment condition of polymer insulators. The investigation reported examined the HF-CT waveform characteristics at high frequencies. The use of high frequency measurements for on-line applications reduces electrical inference. This work was peformed utilizing HF-CT to monitor of surface polluted discharge. It was found that HF-CT waveform frequency spectrum, magnitude depend on importantly the duration of the surface discharge activity.

  • PDF

토양의 종류에 따른 초음파토양세척의 투수특성 분석

  • 정하익;송봉준;이용수;유준;강동우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.258-261
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique onto simple soil flushing was studied for the enhancement of water and liquid flows and the removal of contaminants in contaminated soils. The ultrasonic technique has been used to increase liquid flow and remove pollutants in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory permeability experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests.

  • PDF

옥외에서 사용되는 배전용 폴리머애자의 인공오손 특성 (The Characteristics of Artificial Contamination of Distribution Polymer Insulators Used for Outdoor Insulation)

  • 이병성;한재홍;김찬영;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.595-597
    • /
    • 2000
  • Poymeric insulators using in an heavy contamination area are easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we manufactured slurry mixed by some kaolin and salt as artificial contaminated solution. And then put samples in its slurry, for about one minute. And these samples are dried in natural condition for 6 days. We measured the degree of contaminant, AC leakage current for these contaminated samples.

  • PDF

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF

동전기 및 초음파 복원기술에 의한 오염지반내의 중금속 및 유기오염물질 제거 (Removal of Heavy Metal and Organic Substance in Contaminated Soils by Electrokinetic and Ultrasonic Remediation)

  • Chung, Ha-Ik
    • 한국지반공학회논문집
    • /
    • 제19권3호
    • /
    • pp.83-91
    • /
    • 2003
  • 본 논문에서는 동전기초음파정화기술을 이용하여 오염지반내의 중금속 및 유기물질을 제거하는 연구를 수행하였는데, 지반내 오염물질의 이동 및 제거에 대한 동전기기술과 초음파기술의 복합효과 분석에 초점을 두었다. 일반적으로 오염지반내에서 동전기기술은 중금속을 제거하는데 탁월하며 초음파기술은 유기물질을 제거하는데 탁월한 것을 보고되어 있는바 이들 두 기술의 장점을 이용한 복합기술을 고안하게 되었다. 특수하게 고안된 실험장비를 이용하여 동전기기술과 초음파기술을 결합한 실내토양세척실험을 실시하였다. 본 실험에서는 단순, 동전기, 초음파, 동전기&초음파의 4조건에 대하여 토양세척실험을 실시하였다. 오염물질로는 중금속으로는 납, 유기물질로는 에틸렌글리콜을 사용하였다. 실험결과 동전기기술과 초음파기술을 도입한 경우 유출량, 투수계수, 오염물질 제거율이 단순기술에 비하여 상대적으로 크게 증가하는 것으로 나타났다. 본 연구를 통하여 동전기초음파정화기술을 현장에 적용할 수 있는 가시적인 결과를 얻게 되었다.

오염퇴적토에 대한 동전기적 침전 및 정화 공정에서의 시료 밀도 및 침하 변화 특성 (The Variation of Density and Settlement for Contaminated Sediments During Electrokinetic Sedimentation and Remediation Processes)

  • 정하익
    • 한국지반공학회논문집
    • /
    • 제22권9호
    • /
    • pp.5-14
    • /
    • 2006
  • 본 논문에서는 유기물질로 오염된 퇴적토에서 동전기 침전 및 정화 기법을 이용하여 초연약한 퇴적토의 침하를 촉진시켜 밀도를 증진시키는 연구를 수행하였다. 본 논문에서는 인체에 무해한 에틸렌글리콜 유기물질을 일반수와 적정하게 섞은 오염수에 카오리나이트 점토를 혼합하여 함수비가 높은 슬러리 상태를 조성하여 만든 오염된 퇴적토를 시료로 사용하였다. 일반적으로 동전기기법을 이용한 전기영동 및 전기삼투에 의하여 슬러리내의 고형물 입자를 음극으로 이동시키고 간극수를 양극으로 배제시킬 수 있는 것으로 보고되고 있다. 본 연구에서는 오염된 퇴적토에 대하여 고형물함량, 공급전압 및 오염농도를 변화시키면서 동전기침전 및 동전기정화 시험을 연속적으로 동시에 수행하였으며 동전기침전 및 동전기정화 공정에서 발생한 시료의 침하 및 밀도 변화에 대하여 살펴보았다. 시험결과 오염퇴적토의 침하량은 공급전압이 클수록 고형물함량 및 오염농도가 작을수록 증가하는 것으로 나타났다. 그리고 오염퇴적토의 밀도는 동전기 침전단계에서는 시료의 침하에 의하여 증가하고 동전기 정화단계에서는 물보다 무거운 유기물질의 유출에 의하여 감소하는 것으로 나타났다.