• 제목/요약/키워드: Kaolin Contaminant

검색결과 11건 처리시간 0.021초

애자표면의 오손물 누적에 관한 메커니즘 연구 (A Study on Mechanism about Contaminant Accumulation of Insulator Surface)

  • 박재준
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성 (A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents)

  • 박재준;송일근;이재봉;천성남
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

카올린 오손물 누적량 및 누설전류 변화에 관한 연구 (A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation)

  • 박재준;송일근;이재봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석 (Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • 이병성;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

오염퇴적토에 대한 동전기적 침전 및 정화 공정에서의 시료 밀도 및 침하 변화 특성 (The Variation of Density and Settlement for Contaminated Sediments During Electrokinetic Sedimentation and Remediation Processes)

  • 정하익
    • 한국지반공학회논문집
    • /
    • 제22권9호
    • /
    • pp.5-14
    • /
    • 2006
  • 본 논문에서는 유기물질로 오염된 퇴적토에서 동전기 침전 및 정화 기법을 이용하여 초연약한 퇴적토의 침하를 촉진시켜 밀도를 증진시키는 연구를 수행하였다. 본 논문에서는 인체에 무해한 에틸렌글리콜 유기물질을 일반수와 적정하게 섞은 오염수에 카오리나이트 점토를 혼합하여 함수비가 높은 슬러리 상태를 조성하여 만든 오염된 퇴적토를 시료로 사용하였다. 일반적으로 동전기기법을 이용한 전기영동 및 전기삼투에 의하여 슬러리내의 고형물 입자를 음극으로 이동시키고 간극수를 양극으로 배제시킬 수 있는 것으로 보고되고 있다. 본 연구에서는 오염된 퇴적토에 대하여 고형물함량, 공급전압 및 오염농도를 변화시키면서 동전기침전 및 동전기정화 시험을 연속적으로 동시에 수행하였으며 동전기침전 및 동전기정화 공정에서 발생한 시료의 침하 및 밀도 변화에 대하여 살펴보았다. 시험결과 오염퇴적토의 침하량은 공급전압이 클수록 고형물함량 및 오염농도가 작을수록 증가하는 것으로 나타났다. 그리고 오염퇴적토의 밀도는 동전기 침전단계에서는 시료의 침하에 의하여 증가하고 동전기 정화단계에서는 물보다 무거운 유기물질의 유출에 의하여 감소하는 것으로 나타났다.

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF

토양의 종류에 따른 초음파토양세척의 투수특성 분석

  • 정하익;송봉준;이용수;유준;강동우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.258-261
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique onto simple soil flushing was studied for the enhancement of water and liquid flows and the removal of contaminants in contaminated soils. The ultrasonic technique has been used to increase liquid flow and remove pollutants in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory permeability experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests.

  • PDF

옥외에서 사용되는 배전용 폴리머애자의 인공오손 특성 (The Characteristics of Artificial Contamination of Distribution Polymer Insulators Used for Outdoor Insulation)

  • 이병성;한재홍;김찬영;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.595-597
    • /
    • 2000
  • Poymeric insulators using in an heavy contamination area are easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we manufactured slurry mixed by some kaolin and salt as artificial contaminated solution. And then put samples in its slurry, for about one minute. And these samples are dried in natural condition for 6 days. We measured the degree of contaminant, AC leakage current for these contaminated samples.

  • PDF

중금속 오염토의 Electrokinetic 정화 처리시 pH 발현과 납 제거의 전극 간 특성 (The Characteristics of pH Variations and Lead transport during Electrokinetic Remediation of soil Contaminated by Heavy Metal)

  • 한상재;김수삼
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권4호
    • /
    • pp.13-23
    • /
    • 2001
  • 본 연구는 중금속 오염지반의 정화를 목적으로, Electrokinetic(EK) 기법을 적용 할 때 지반 내에서 pH와 오염물 분포특성을 알아보았다. 시료 내에서의 EK 처리로 인한 납 제거 효과를 살펴본 결과 1V/cm의 전압경사 하에서 납은 음극으로 이동하여, 전극 간 시료의 80%정도 영역에서 제거율은 대략 75% 정도에 이르렀다. 그러나 이동된 납은 대부분이 음극영역에 침전되어 궁극적으로 음극수로 배출되어 제거되는 납의 양은 미미하였다. 이때, EK 정화처리는 시료의 대부분인 80% 정도에서 토양환경보전법 상의 규준치를 만족할 수 있으나, 음극쪽 20%지역은 별도의 향상기법을 적용하여 처리하는 기법이 필요하다.

  • PDF