• Title/Summary/Keyword: Kaolin Contaminant

Search Result 11, Processing Time 0.021 seconds

A Study on Mechanism about Contaminant Accumulation of Insulator Surface (애자표면의 오손물 누적에 관한 메커니즘 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents (Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성)

  • ark, Jae-.Jun;Song, Il-keun;Lee, Jae-bong;Chun, Sung-nam
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation (카올린 오손물 누적량 및 누설전류 변화에 관한 연구)

  • Park, Jae-Jun;Song, Il-Keun;Lee, Jae-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters (배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

The Variation of Density and Settlement for Contaminated Sediments During Electrokinetic Sedimentation and Remediation Processes (오염퇴적토에 대한 동전기적 침전 및 정화 공정에서의 시료 밀도 및 침하 변화 특성)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.9
    • /
    • pp.5-14
    • /
    • 2006
  • Generally, the sediments contain significant water, clay, colloidal fraction and contaminants, and can result in soft strata with high initial void, and its potential hazards in subsurface environments exist. Electrokinetic technique has been used in sedimentation for volume reduction of slurry tailing wastes and in remediation for extraction of contaminants from contaminated soils. In this research, the coupled effects of sedimentation and remediation of contaminated sediments are focused using electrokinetic sedimentation and remediation techniques from experimental aspects. A series of laboratory experiments including variable conditions such as initial solid content of the specimen, concentration level of the contaminant, and magnitude of applied voltage are performed with the contaminated sediment specimens mixed with ethylene glycol. Commercially available high specification Kaolin was used to simulate slurried sediment. From the test results, the settlement of specimen increases with increasing of applied voltage and decreasing of solid content and contamination level. The density of specimen increases due to settlement of specimen in the process of electrokinetic sedimentation and decreases due to extraction of organic contaminant in the process of electrokinetic remediation.

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF

토양의 종류에 따른 초음파토양세척의 투수특성 분석

  • 정하익;송봉준;이용수;유준;강동우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.258-261
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique onto simple soil flushing was studied for the enhancement of water and liquid flows and the removal of contaminants in contaminated soils. The ultrasonic technique has been used to increase liquid flow and remove pollutants in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory permeability experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests.

  • PDF

The Characteristics of Artificial Contamination of Distribution Polymer Insulators Used for Outdoor Insulation (옥외에서 사용되는 배전용 폴리머애자의 인공오손 특성)

  • 이병성;한재홍;김찬영;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.595-597
    • /
    • 2000
  • Poymeric insulators using in an heavy contamination area are easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we manufactured slurry mixed by some kaolin and salt as artificial contaminated solution. And then put samples in its slurry, for about one minute. And these samples are dried in natural condition for 6 days. We measured the degree of contaminant, AC leakage current for these contaminated samples.

  • PDF

The Characteristics of pH Variations and Lead transport during Electrokinetic Remediation of soil Contaminated by Heavy Metal (중금속 오염토의 Electrokinetic 정화 처리시 pH 발현과 납 제거의 전극 간 특성)

  • 한상재;김수삼
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.13-23
    • /
    • 2001
  • In this study, the characteristics of pH variations and contaminant distribution in soil are investigated during electrokinetic treatment for the purpose of restoring contaminated soil with heavy metal. For these objects, laboratory test for the kaolin contaminated by lead was performed. During electrokinetic treatment, lead was transported from anode to cathode. And 75% of lead removed within 80% region of the specimen. Most lead, however, that transported from anode to cathode precipitated in the vicinity of cathode compartment, thus the amount of lead removed by electroosmosis was little. Electrokinetic treatment satisfied regulation criteria of Korean Soil Environment Conservation Law within almost region of the specimen. But enhancement methods can be regarded as inevitable requisite for the cathode region.

  • PDF